Table of Contents Table of Contents
Previous Page  240 / 298 Next Page
Information
Show Menu
Previous Page 240 / 298 Next Page
Page Background

• 14 •

www.restekcorp.com

RESTEK Advantage

800-356-1688

Similar to

Description

PE part #

Qty.

cat.#

A

O-Ring Liner Seals for PerkinElmer PSS

N6101747

10-pk.

20366

B

O-Rings Liner Seals for PerkinElmer Auto SYS

®

GCs

N6101374

10-pk.

20262

Peak Performers

Easily attach your purge and trap with pre-installed low dead volume fittings.

For Agilent GCs with Tekmar purge and trap systems

Description

qty.

cat.#

Weldment for Agilent 6890 GCs

ea.

22664

Weldment for Agilent 6890 GCs with optional canister filter

ea.

22668

Weldment for Agilent 5890 GCs

ea.

22666

For Agilent GCs with OI purge and trap systems

Description

qty.

cat.#

Weldment for Agilent 6890 GCs

ea.

22665

Weldment for Agilent 6890 GCs with optional canister filter

ea.

22669

Weldment for Agilent 5890 GCs

ea.

22667

Injector/FID Heater & PRT Sensor for Agilent 5890 GCs

Use with 5890 FID and split/splitless weldments.

Meets or exceeds OEM specifications.

Description

Similar to

Agilent part # qty.

cat.#

A+B

Injector/FID Heater/PRT Sensor Assembly

05890-61140

ea.

22068

A

Injector/FID Heater

19231-60620

ea.

22069

B

Injector/FID PRT Sensor

19231-60660

ea.

22070

Heat Sink for Agilent 5890/6890/6850 GC Split/Splitless Injector

Meets or exceeds original equipment manufacturer’s specifications.

Description

Similar to Agilent part # qty.

cat.#

Heat Sink for Agilent 5890/6890/6850 GCs

18740-20940

G1544-20570

ea.

20409

B

A

PSS Inlet Liners and O-Ring Liner Seals for PerkinElmer GCs

deactivated!

all liners are

For more information:

Request our current catalog (lit. cat.# 59473) for a complete listing of our consumables

for Agilent, Varian, Shimadzu, PerkinElmer, and Thermo instruments.

PSS Liners

for PerkinElmer GCs

Benefits/Uses:

ID*/OD &

Length (mm)

Similar to

PE part #

cat.#

ea.

cat.#

5-pk.

PSS Split/Splitless (1mm ID)

trace

samples

1.0 ID

4.0 OD x 86.2

N612-1006

20738

20741

Auto SYS

®

XL PSS Split/Splitless w/ FS Wool

most

common analyses

2.0 ID

4.0 OD x 86.2

N612-1004

21717

21718

For use with Tekmar

purge and trap system

For use with OI

purge and trap system

By Donna Lidgett, GC Accessories Products Marketing Manager

A

B

Direct Replacement Split/Splitless Injection Port Weldments for Agilent GCs,

for use with Purge and Trap Systems

*Nominal ID at syringe needle expulsion point.

cat.# 22666

cat.# 22665