Table of Contents Table of Contents
Previous Page  238 / 298 Next Page
Information
Show Menu
Previous Page 238 / 298 Next Page
Page Background

GC_EV00379

4

5

6

7

8

9

10 11 12 13 14 15 16

17 18

19 20 21 22 23 min.

1

3

4

5

6

7

8

9/10

11

12

13

14

15

16

17

18

19

20

21

22/23 24

25

26

27

28

29

30

31

32

33

34

35/36

37

38

39

40

41 42

43 44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60 61

62

63

BFB

2

• 12 •

www.restekcorp.com

RESTEK Advantage

800-356-1688

Canisters Optimized for Air Sampling

by EPA Methods TO-14 and TO-15

By Donna Lidgett, Air Sampling Products Marketing Manager

SUMMA

®

canister equivalent.

Excellent analyte recovery — even after 14 days of storage.

TO-Can

Canisters for EPA Methods TO-14 and TO-15

volume

qty.

cat.#

1L

ea.

24150

3L

ea.

24152

6L

ea.

24153

15L

ea.

24154

Chromatogram courtesy of Gina Maio, Severn Trent Laboratories, Inc., Burlington, VT.

Figure 1

- TO-Can

canisters ensure excellent recovery for TO-14/TO-15 compounds, even after 14 days of storage.

Feature

US Environmental Protection Agency (EPA)

Compendium of Air Methods TO-14 and TO-15

regulate the collection, storage, and analysis of

volatile organic compounds (VOCs) using treated

air sampling canisters.

Restek offers a line of TO-Can

canisters (SUMMA

®

can equivalent), which are electropolished and

extensively cleaned using proprietary processes.

This ensures a high-quality, passivated surface to

maintain stability of the TO-14/TO-15 compounds

during storage. The design of the frame surround-

ing the electropolished canister eliminates welds

on the sphere, thereby eliminating active sites. A

Parker Hannifin metal-to-metal diaphragm valve

further improves the performance of the canister.

To collect VOCs in ambient air, TO-Can

canis-

ters should be cleaned and evacuated prior to

being sent to the field. In the field, the sample is

drawn through a sampling train that regulates

the rate and duration of sampling. The TO-Can

canister is then sent to the analytical laboratory.

In the laboratory, a known amount of sample is

drawn from the canister and concentrated onto a

trap. The sample is analyzed according to

Method TO-14/TO-15, typically using a 60m,

0.32mm ID, 1.0µm Rtx

®

-1 capillary column in a

GC/MS system.

To show the inertness of these canisters, and how

well they meet the holding time criteria for Methods

TO-14/15, a 62-component TO-15 standard

(10ppbv) was injected into a TO-Can

canister and

humidified to 70% relative humidity. The standard

was analyzed on day 1, day 7, and day 14. The TO-

Can

canister ensured excellent stability for these

polar and non-polar compounds, even after 14

days of storage (for data, request lit. cat.# 59189).

We also offer sampling kits, sampling bags, thermal

desorption tubes, and a range of gas reference

standards to meet your environmental gas sampling

requirements.

Vacuum/pressure gauge (optional).

Variety of sizes.

Temperature stability to 250°C.

High-purity,

2

/

3

-turn valve with stainless steel diaphragms.

No sample adsorption, for more accurate results; easy to use.

Indicates internal conditions.

Meet a range of sampling needs.

Higher temperature cleaning saves time.

Benefit

TO-Can

Canisters with Vacuum/Pressure Gauge

volume

qty.

cat.#

1L

ea.

24155

3L

ea.

24156

6L

ea.

24157

15L

ea.

24158

Rtx

®

-1 column, 60m, 0.32mm ID, 1.0µm (cat.# 10157).

Sample:

200mL of 10ppbv TO-15 standard (cat.# 34436), injected into TO-Can

canister and humidified to 70% RH.

Concentrator:

Nutech 3550 Preconcentrator

200mL of sample concentrated at 160°C, thermally desorbed at 150°C, and cryofocused at 185°C.

Oven Temp.:

30°C (hold 4 min.) to 175°C @ 9°C/min. to

220°C @ 40°C/min.

Carrier Gas:

helium @ 1.2mL/min.

Det.:

Agilent 5971 MS

Scan Range:

35-265amu

For peak indentifications, request

Applications Note #59189.

For more information, request our Air Monitoring

Products Catalog (lit. cat. #59661A).

For information about environmental gas

reference mixes, request lit. cat.#59276A.