Leak Detective

II

A Compact, Sensitive Leak Detector for Every Analyst

• 5 •

www.restekcorp.com

Ordering Information

| Rtx

®

-5Sil MS Columns (Fused Silica)

(Similar selectivity to Crossbond

®

5% diphenyl/95% dimethyl polysiloxane)

ID

df (µm)

temp. limits

15-Meter

30-Meter

0.25mm

0.10

-60 to 330/350°C

12705

12708

0.25

-60 to 330/350°C

12720

12723

0.50

-60 to 330/350°C

12735

12738

1.00

-60 to 325/350°C

12750

12753

0.28mm

0.25

-60 to 330/350°C

12790

12793

0.50

-60 to 330/350°C

12791

12794

1.00

-60 to 325/350°C

12792

12795

0.32mm

0.10

-60 to 330/350°C

12706

12709

0.25

-60 to 330/350°C

12721

12724

0.50

-60 to 330/350°C

12736

12739

1.00

-60 to 325/350°C

12751

12754

0.53mm

0.50

-60 to 320/340°C

12737

12740

1.00

-60 to 320/340°C

12752

12755

1.50

-60 to 310/330°C

12767

12770

DI Liners for Agilent 5890 & 6890 GCs

(For 0.25/0.32/0.53mm ID Columns)

ID*/OD &

Length (mm)

cat.#/price

ea.

cat.#/price

5-pk.

Drilled Uniliner

®

4.0 ID

6.3 OD x 78.5

21054

21055

Siltek

Drilled Uniliner

®

4.0 ID

6.3 OD x 78.5

21054-214.1 21055-214.5

Siltek

1mm Drilled Uniliner

®

1.0 ID

6.3 OD x 78.5

21390-214.1 21391-214.5

acetochlor

cyanazine

diazinon

2,4-dichlorophenol

1,2-diphenylhydrazine

disulfoton

fonofos

nitrobenzene

prometon

terbufos

2,4,6-trichlorophenol

200µg/mL each in ethyl acetate, 1mL/ampul

Semivolatile Calibration Mix, EPA 526

(11 compounds)

Each

5-pk.

10-pk.

31691

31691-510

w/data pack

31691-500

31691-520

31791

acenaphthene-d10

chrysene-d12

phenanthrene-d10

500µg/mL each in acetone, 1mL/ampul

Internal Standard Mix, EPA 526

Each

5-pk.

10-pk.

31692

31692-510

w/data pack

31692-500

31692-520

31792

2-nitro-

m

-xylene

triphenylphosphate

500µg/mL each in acetone, 1mL/ampul

Surrogate Standard Mix, EPA 526

Each

5-pk.

10-pk.

31693

31693-510

w/data pack

31693-500

31693-520

31793

Hole makes

direct injection

possible with

EPC-equipped

Agilent 6890

GCs!

Resprep

Resin SPE Disks

• For chlorinated, benzidene-containing, or nitrogen-containing pesticides.

• Meet description in EPA Methods 515.2, 553, and 526.

• 47mm glass fiber embedded with styrene/DVB resin.

Description

qty.

cat.#

price

Resprep

Resin SPE Disks

20-pk.

26023

Diskcover

-47 Extraction Disk Holder

• Compatible with most vacuum manifold systems that accept

1

/

8

-inch male luer fittings.

• Sample can be automatically introduced via

1

/

8

-inch Teflon

®

tubing or by the optional Diskcover

-47 reservoir.

Description

qty.

cat.#

price

Diskcover

-47

ea.

24020

Diskcover

-47

6-pk.

24021

Refer to our

Chromatography Products

Catalog

(lit. cat.# 59473) for manifolds.

Ordering Information

| Drilled Uniliner

®

Inlet Liners

Gas leaks in your GC system can increase detector

noise, cause baseline instability, waste carrier gas,

and damage valuable analytical columns. Leak

checks should be a regular part of your GC mainte-

nance program. The new Leak Detective

II

elec-

tronic leak detector is the affordable solution for

detecting gas leaks. It will identify minute gas leaks

that might go undetected by liquid leak detectors.

The Leak Detective

II

electronic leak detector

incorporates microchip technology and a new design,

to give you better sensitivity and faster response time

in a more compact unit. An auto-zero feature allows

*Never use liquid leak detectors on a capillary system because liquids can be drawn into the column.

Caution: NOT designed for determining leaks of combustible gases. A combustible gas detector should be used for determining com-

bustible gas leaks in possibly hazardous conditions.

Description

qty.

cat.#

price

Leak Detective

II

Leak Detector

ea.

20413

Affordable thermal conductivity leak detector—every analyst should have one.

Compact, ergonomic design is easy to hold and operate.

Detects helium, hydrogen, and nitrogen at 1x10

-4

cc/sec. or at an absolute concentration as

low as 100ppm.*

you to instantly zero the leak detector with a push of

a button, and the ergonomic design brings all the

controls to your fingertips for easy use. The unit

responds in less than two seconds to trace leaks of

gases with thermal conductivities different than air.

Helium, hydrogen, and nitrogen can be detected at

1x10

-4

cc/sec or at an absolute concentration as low

as 100ppm.* Leaks are indicated by an audible

alarm, as well as by an LED readout. For easy, sensi-

tive, and reliable leak detection, order a new Leak

Detective

II

electronic leak detector today.

*Nominal ID at syringe needle expulsion point.