by Christopher English, Environmental Innovations Chemist, & Brad Rightnour, Instrument Innovations Manager

EZ No-Vent

GC Column-

Mass Spectrometer Connector

Change Columns in Minutes, Without Venting

Easy to install and maintain—no special tools or extra plumbing required.

Gold plated for inertness.

100µm ID transfer line keeps analytes focused.

Lower cost than other “no-vent” fittings.

We designed our new EZ No-Vent

GC column-mass

spectrometer connector to be simple and easy to

use. After studying user feedback concerning our

EZ-Vent

2000 connector, we re-engineered the

connector fitting for even better performance.

A critical orifice in the EZ No-Vent

connector min-

imizes the amount of oxygen allowed into the MS

source, eliminating the need for purge gas and

enabling you to skip the lengthy vent and pump-

down cycle otherwise required when you make a

column change. This can save nearly a day of

downtime with each column change. The EZ No-

Vent

connector easily attaches to the MS source

without special tools or extra plumbing. Figure 1

shows the fitting installed and ready for use.

We tested the EZ No-Vent

connector, using highly

volatile gaseous sample components that are very

susceptible to tailing in the presence of dead vol-

ume. We operated the system as a purge-and-trap

GC/MS system, initially with a split at the injection

port and the column inserted directly into the MS

interface. Next, we included the EZ No-Vent

con-

nector at the MS interface. We anticipated that any

dead volume in this fitting would produce signifi-

cant tailing and broader peaks, relative to the direct

connection. Peak shape was excellent using the new

fitting.

Similarly, we used an application-specific test to

evaluate the ability of the MS to stabilize after we

changed columns without venting. Again we used a

purge-and-trap system, halogenated volatiles as the

sample, and an Rtx

®

-624 column to separate the

analytes. We acquired Figure 2a at 08:12 AM, then

changed the column. We acquired Figure 2b 76

minutes later, at 09:28 AM. Note the excellent peak

shapes and responses. In the interval between the

two analyses we verified MSD tuning, and the sys-

tem passed bromofluorobenzene (BFB) criteria.

Subsequent detailed investigations have established

that the EZ No-Vent

connector will allow several

column changes in a single day, with no harm to

the MS or loss of data quality.

If you’re tired of waiting for your MS to stabilize, we

highly recommend you use an EZ No-Vent

connec-

tor. It will reduce your MS downtime, saving you

money, and increase your sample throughput—

making you money.

Figure 1

MS transfer line installed in an EZ No-Vent

connector. Connection can be made quickly,

without special tools.

Figure 2

Acquire a sample within two hours of changing columns, using an EZ No-Vent

connector.

expanded view

Description

qty.

cat.#

price

EZ No-Vent

Connector Kit for Agilent 5971/5972 and 5973 GC/MS

(Kit includes: EZ No-Vent

Connector, 0.4mm ID ferrules for connecting capillary

column, 0.4mm ID ferrules for connecting transfer line, 100µm deactivated transfer

line (3 ft.), and EZ No-Vent

column plug and nut.)

kit

21323

Replacement ferrules for connecting capillary column to EZ No-Vent

:

0.4mm ID

2-pk.

21015

0.5mm ID

2-pk.

21016

Replacement ferrules for connecting transfer line to

EZ-No Vent

: 0.4mm ID

2-pk.

21043

Replacement deactivated transfer line: 100µm ID

3 ft.

21018

Replacement EZ No-Vent

Column Nut

5-pk.

21900

Replacement EZ No-Vent

Plug

2-pk.

21915

Open-end Wrenches (

1

/

4

" x

5

/

16

")

2-pk.

20110

3 4 5 6 7 8 9 10 11 12

20 min.

13 14 15

19 18 17 16

5 6

4 3

7 8 9 10 11 12 13 14 15 16 17 18 19

min.

20

GC_EV00659c

GC_EV00659d

Restek

Innovation!

Rtx

®

-624 60m, 0.25mm ID, 1.4µm (cat# 10969)

Halogenated Volatiles @ 200 ppb in 5mL/RO water.

502.2 Calibration Mix#1 (gases)

cat# 30042

502.2 Calibration Mix#2

cat# 30043

BTEX standard

cat# 30213

2b—acquired at 9:28am

Ez-No Vent

, acquired 76 min. after installing new column

Inj.:

purge & trap

GC:

Agilent 6890

Inj. temp.:

300°C

Carrier gas:

helium, constant flow

Flow rate:

1.0mL/min.

Oven temp.:

60°C (hold 15 min.) to

220°C @ 30°C/min.

(hold 1 min.)

Det:

Agilent 5973 GC/MS

Transfer line temp.:

280°C

Scan range:

35-550 amu

Tune:

BFB

Ionization:

EI

for

more

info

request lit. cat.# 59498.

2a—acquired at 8:12am

Did you know?

Restek offers supplies and inno-

vative tools for your MS. Refer to

the Instrument Supplies section

of the annual

Chromatography

Products Guide

(lit. cat.# 59473).