Table of Contents Table of Contents
Previous Page  187 / 298 Next Page
Information
Show Menu
Previous Page 187 / 298 Next Page
Page Background

DI Liners for Agilent 5890 & 6890 GCs

(For 0.25/0.32/0.53mm ID Columns)

ID*/OD &

Length (mm)

cat.#

/price

ea.

cat.#

/price

5-pk.

Drilled Uniliner

®

4.0 ID

6.3 OD x 78.5

21054

21055

Siltek

Drilled Uniliner

®

4.0 ID

6.3 OD x 78.5

21054-214.1

21055-214.5

Siltek

1mm Drilled Uniliner

®

1.0 ID

6.3 OD x 78.5

21390-214.1

21391-214.5

• 13 •

www.restekcorp.com

800-356-1688

Figure 2

Chlorinated pesticides show excellent response using the Drilled Uniliner

®

inlet liner and Rtx

®

-CLPesticides columns—even at the

20/40/200ng/mL concentration level.

Hole makes

direct injection

possible with

EPC-equipped

Agilent 6890

GCs!

Ordering Information

| Rtx

®

-CLPesticides2 Columns (Fused Silica)

ID

df (µm)

temp. limits

10-Meter

15-Meter

20-Meter

30-Meter

60-Meter

0.10mm

0.10 -60 to 310/330°C 43301

43302

0.18mm

0.14 -60 to 310/330°C 42301

42302

0.25mm

0.20 -60 to 320/340°C

11320

11323

11326

0.32mm

0.25 -60 to 320/340°C

11321

11324

0.53mm

0.42 -60 to 300/320°C

11337

11340

Ordering Information

| Rtx

®

-CLPesticides Columns (Fused Silica)

GC_EV00635

Column:

Rtx

®

-CLPesticides 30m, 0.32 ID, 0.50µm (cat.# 11139)

Sample:

20–400µg/mL Organochlorine Pesticide Mix AB #2 (cat.# 32292)

in hexane:toluene (1:1)

200µg/mL Pesticide Surrogate Mix (cat.#32000 ) in acetone

Inj.:

1.0µL direct, open-top drilled Uniliner

®

inlet liner (cat.# 21054)

Inj. temp.:

225°C

Carrier gas:

helium, constant pressure

Linear velocity:

53cm/sec. @ 110°C

Oven temp.:

110°C (hold 1min.) to 245°C @ 20°C/min. to 310°C (hold 1 min.)

Det.:

ECD @ 330°C

1. 2,4,5,6-tetrachloro-

m

-xylene (TCMX)

2.

α

-BHC

3.

γ

-BHC

4.

β

-BHC

5.

δ

-BHC

6. heptachlor

7. aldrin

8. heptachlor epoxide

9.

γ

-chlordane

10.

α

-chlordane

11. 4,4'-DDE

12. endosulfan I

13. dieldrin

14. endrin

15. 4,4'-DDD

16. endosulfan II

17. 4,4'-DDT

18. endrin aldehyde

19. methoxychlor

20. endosulfan sulfate

21. endrin ketone

22. decachlorobiphenyl (DCB)

GC_EV00636

Column:

Rtx

®

-CLPesticides2 30m, 0.32 ID, 0.25µm (cat.# 11324)

Sample:

20–400µg/mL Organochlorine Pesticide Mix AB #2 (cat.# 32292)

in hexane:toluene (1:1)

200µg/mL Pesticide Surrogate Mix (cat.#32000 ) in acetone

Inj.:

1.0µL direct, open-top drilled Uniliner

®

inlet liner (cat.# 21054)

Inj. temp.:

225°C

Carrier gas:

helium, constant pressure

Linear velocity:

53cm/sec. @ 110°C

Oven temp.:

110°C (hold 1min.) to 245°C @ 20°C/min. to 310°C (hold 1 min.)

Det.:

ECD @ 330°C

for

more

info

for additional data from these

analyses, request Applications

Note 59487.

ID

df (µm)

temp. limits

10-Meter

15-Meter

20-Meter

30-Meter

60-Meter

0.10mm 0.10

-60 to 310/330°C 43101

0.18mm 0.18

-60 to 310/330°C 42101

42102

0.25mm 0.25

-60 to 320/340°C

11120

11123

11126

0.32mm 0.50

-60 to 320/340°C

11136

11139

0.53mm 0.50

-60 to 300/320°C

11137

11140

Rtx

®

-CLPesticides columns are available in

convenient and economical kits

that include a deactivated guard column and

a connector. Refer to our general catalog, or

contact your local Restek representative.

Plus 1

means that we will surpass your

expectations every time you contact us.

Looking for the solution to your tough ana-

lytical problem or placing a late-day order?

Contact us to experience Plus 1

service

today!

*Nominal ID at syringe needle expulsion point.