DI Liners for Agilent 5890 & 6890 GCs
(For 0.25/0.32/0.53mm ID Columns)
ID*/OD &
Length (mm)
cat.#
/price
ea.
cat.#
/price
5-pk.
Drilled Uniliner
®
4.0 ID
6.3 OD x 78.5
21054
21055
Siltek
™
Drilled Uniliner
®
4.0 ID
6.3 OD x 78.5
21054-214.1
21055-214.5
Siltek
™
1mm Drilled Uniliner
®
1.0 ID
6.3 OD x 78.5
21390-214.1
21391-214.5
• 13 •
www.restekcorp.com800-356-1688
Figure 2
Chlorinated pesticides show excellent response using the Drilled Uniliner
®
inlet liner and Rtx
®
-CLPesticides columns—even at the
20/40/200ng/mL concentration level.
Hole makes
direct injection
possible with
EPC-equipped
Agilent 6890
GCs!
Ordering Information
| Rtx
®
-CLPesticides2 Columns (Fused Silica)
ID
df (µm)
temp. limits
10-Meter
15-Meter
20-Meter
30-Meter
60-Meter
0.10mm
0.10 -60 to 310/330°C 43301
43302
0.18mm
0.14 -60 to 310/330°C 42301
42302
0.25mm
0.20 -60 to 320/340°C
11320
11323
11326
0.32mm
0.25 -60 to 320/340°C
11321
11324
0.53mm
0.42 -60 to 300/320°C
11337
11340
Ordering Information
| Rtx
®
-CLPesticides Columns (Fused Silica)
GC_EV00635
Column:
Rtx
®
-CLPesticides 30m, 0.32 ID, 0.50µm (cat.# 11139)
Sample:
20–400µg/mL Organochlorine Pesticide Mix AB #2 (cat.# 32292)
in hexane:toluene (1:1)
200µg/mL Pesticide Surrogate Mix (cat.#32000 ) in acetone
Inj.:
1.0µL direct, open-top drilled Uniliner
®
inlet liner (cat.# 21054)
Inj. temp.:
225°C
Carrier gas:
helium, constant pressure
Linear velocity:
53cm/sec. @ 110°C
Oven temp.:
110°C (hold 1min.) to 245°C @ 20°C/min. to 310°C (hold 1 min.)
Det.:
ECD @ 330°C
1. 2,4,5,6-tetrachloro-
m
-xylene (TCMX)
2.
α
-BHC
3.
γ
-BHC
4.
β
-BHC
5.
δ
-BHC
6. heptachlor
7. aldrin
8. heptachlor epoxide
9.
γ
-chlordane
10.
α
-chlordane
11. 4,4'-DDE
12. endosulfan I
13. dieldrin
14. endrin
15. 4,4'-DDD
16. endosulfan II
17. 4,4'-DDT
18. endrin aldehyde
19. methoxychlor
20. endosulfan sulfate
21. endrin ketone
22. decachlorobiphenyl (DCB)
GC_EV00636
Column:
Rtx
®
-CLPesticides2 30m, 0.32 ID, 0.25µm (cat.# 11324)
Sample:
20–400µg/mL Organochlorine Pesticide Mix AB #2 (cat.# 32292)
in hexane:toluene (1:1)
200µg/mL Pesticide Surrogate Mix (cat.#32000 ) in acetone
Inj.:
1.0µL direct, open-top drilled Uniliner
®
inlet liner (cat.# 21054)
Inj. temp.:
225°C
Carrier gas:
helium, constant pressure
Linear velocity:
53cm/sec. @ 110°C
Oven temp.:
110°C (hold 1min.) to 245°C @ 20°C/min. to 310°C (hold 1 min.)
Det.:
ECD @ 330°C
for
more
info
for additional data from these
analyses, request Applications
Note 59487.
ID
df (µm)
temp. limits
10-Meter
15-Meter
20-Meter
30-Meter
60-Meter
0.10mm 0.10
-60 to 310/330°C 43101
0.18mm 0.18
-60 to 310/330°C 42101
42102
0.25mm 0.25
-60 to 320/340°C
11120
11123
11126
0.32mm 0.50
-60 to 320/340°C
11136
11139
0.53mm 0.50
-60 to 300/320°C
11137
11140
Rtx
®
-CLPesticides columns are available in
convenient and economical kits
that include a deactivated guard column and
a connector. Refer to our general catalog, or
contact your local Restek representative.
Plus 1
™
means that we will surpass your
expectations every time you contact us.
Looking for the solution to your tough ana-
lytical problem or placing a late-day order?
Contact us to experience Plus 1
™
service
today!
*Nominal ID at syringe needle expulsion point.