Table of Contents Table of Contents
Previous Page  139 / 298 Next Page
Information
Show Menu
Previous Page 139 / 298 Next Page
Page Background

• 13 •

www.restekcorp.com

800-356-1688

Water Quality Testing

Standards & Columns

ISO/DIS 9377-4 describes a gas

chromatography/flame ionization detection

(GC/FID) method to analyze total petroleum

hydrocarbons (TPHs) in drinking, surface, waste,

and treated waste water. Previous methods used

Freon

®

extraction, which was harmful to the envi-

ronment. This new method uses less harmful sol-

vents such as pentane, hexane, or cyclohexane for

sample extraction.

Restek now offers mixtures for ISO/DIS 9377-4

analyses. Florisil

®

cleanup to remove polar com-

pounds is accomplished using a 150-250µm

(60/100 mesh) sample preparation column. The

analytical column suggested is either an Rtx

®

-1 or

an Rtx

®

-5 column with dimensions of 10-25m,

0.25-0.53mm ID, and 0.25-1.0µm film thickness.

See highlighted columns in product listing for rec-

ommended dimensions.

Standard Mixture Stock Solution

diesel #2 (additive free)

motor oil (additive free bp 325–460 or

C18–C32 retention time range)

5,000 µg/mL each in cyclohexane, 1mL per ampule

(prepares 8mL of 1.25µg/µL calibration curve high point)

Total hydrocarbon concentration 10,000 µg/mL

Ea.

5-pk.

10-pk.

31640

31640-510

with data pack

31640-500

31640-520

31740

Quality Control Standard Mixture

diesel #2 (additive free)

motor oil (additive free bp 325–460 or

C18–C32 retention time range)

500µg/mL each in acetone, 1mL per ampule (enough to spike

one 900mL quality control sample)

Total hydrocarbon concentration 1,000µg/mL

Ea.

5-pk.

10-pk.

31641

31641-510

with data pack

31641-500

31641-520

31741

Florisil

®

Cartridge Quality Control

Standard Mixture

diesel #2 (additive free)

motor oil (additive free bp 325–460 or

C18–C32 retention time range)

1,000µg/mL each in cyclohexane, 10mL per ampule (enough to

check one 2g Florisil

®

/2g sodium sulfate cartridge)

Total hydrocarbon concentration 2,000µg/mL

Ea.

5-pk.

10-pk.

31642

31642-510

with data pack

31642-500

31642-520

31742

Standard Mixture of

n

-alkanes for

System Performance Test

n

-decane

n

-hexacosane

n

-dodecane

n

-octacosane

n

-tetradecane

n

-triacontane

n

-hexadecane

n

-dotriacontane

n

-octadecane

n

-tetratriacontane

n

-eicosane

n

-hexatriacontane

n

-docosane

n

-octatriacontane

n

-tetracosane

n

-tetracontane

50µg/mL each in cyclohexane, 1mL per ampule

Ea.

5-pk.

10-pk.

31633

31633-510

with data pack

31633-500

31633-520

31733

Extraction Solvent Stock Solution #1

n

-decane

20µL/L

n

-tetracontane

20mg/L

in n-hexane, 5mL per ampule (makes 50mL of extraction sol-

vent, enough for 1 sample)

Ea.

5-pk.

10-pk.

31634

31634-510

with data pack

31634-500

31634-520

31734

Extraction Solvent Stock Solution #2

n

-decane

20µL/L

n

-tetracontane

20mg/L

in n-hexane, 20mL per ampule (makes 200mL of extraction

solvent, enough for 4 samples)

Ea.

5-pk.

10-pk.

31635

31635-510

with data pack

31635-500

31635-520

31735

Rtx

®

-5

(fused silica)

Crossbond

®

5% diphenyl/95% dimethyl

polysiloxane

ID df (µm) temp. limits

15-Meter

0.25mm 0.25 -60 to 330/350°C 10220

0.25mm 0.50 -60 to 330/350°C 10235

0.32mm 0.25 -60 to 330/350°C 10221

0.32mm 0.50 -60 to 330/350°C 10236

0.53mm 0.25 -60 to 320/340°C 10222

0.53mm 0.50 -60 to 310/330°C 10237

0.53mm 1.00 -60 to 310/330°C 10252

MXT

®

-5

(Silcosteel

®

)

Crossbond

®

5% diphenyl/95% dimethyl

polysiloxane

ID df (µm) temp. limits

15-Meter

0.25mm 0.25

-60 to 360°C 70220

0.25mm 0.50

-60 to 350°C 70235

0.28mm 0.25

-60 to 360°C 70221

0.28mm 0.50

-60 to 330°C 70236

0.53mm 0.25

-60 to 360°C 70222

0.53mm 0.50

-60 to 330°C 70237

0.53mm 1.00

-60 to 325°C 70252

Stearyl Stearate Test Solution

stearyl stearate

2,000 µg/mL in cyclohexane, 10mL per ampule, (enough to

check one 2g Florisil

®

/2g sodium sulfate cartridge)

Ea.

5-pk.

10-pk.

31636

31636-510

with data pack

31636-500

31636-520

31736

ISO/DIS 9377-4 & H53 Water Quality Testing for

Total Petroleum Hydrocarbons (TPH)

Updated reference materials for GC analysis of TPH in water.

Determination of hydrocarbon oil index—applicable to drinking,

surface, waste, and treated water.

by Ken Herwehe, Analytical Reference Materials Product Marketing Manager

Columns

Check the annual Chromatography Products Guide for

temp. limits. Highlight indicates a recommended

dimension for this analysis.

Rtx

®

-1

(fused silica)

Crossbond

®

100% dimethyl polysiloxane

ID df (µm) temp. limits

15-Meter

0.25mm 0.25 -60 to 330/350°C 10120

0.25mm 0.50 -60 to 330/350°C 10135

0.32mm 0.25 -60 to 330/350°C 10121

0.32mm 0.50 -60 to 330/350°C 10136

0.53mm 0.25 -60 to 320/340°C 10122

0.53mm 0.50 -60 to 310/330°C 10137

0.53mm 1.00 -60 to 310/330°C 10152

MXT

®

-1

(Silcosteel

®

)

Crossbond

®

100% dimethyl polysiloxane

ID df (µm) temp. limits

15-Meter

0.25mm 0.25

-60 to 360°C 70120

0.25mm 0.50

-60 to 350°C 70135

0.28mm 0.25

-60 to 360°C 70121

0.28mm 0.50

-60 to 330°C 70136

0.53mm 0.25

-60 to 360°C 70122

0.53mm 0.50

-60 to 330°C 70137

0.53mm 1.00

-60 to 320°C 70152

new

new

new