Restek Reference Standards 11/12 - page 99

536
REFERENCESTANDARDS |
FOODS, FLAVORS&FRAGRANCESMATERIALS
Food Testing
Equal concentration of all compounds. Suitable for GC/MS analysis.
Varied concentrations. Suitable for GC/ECD analysis.
Equal concentration of all compounds. Suitable for GC/FPD, GC/NPD,
&GC/MS analysis.
FAPAS-registered trademark of Central Science Laboratory, SandHutton, York,
YO41, UK.
FAPAS®FoodTestingProgram*
Laboratories testing food quality and safety are encouraged to
routinely perform proficiency tests. Proficiency testing is an
external check of quality. It provides an independent and unbi-
ased assessment of the performance of all aspects of the labora-
tory,bothhumanandhardware.Eachparticipating laboratory is
encouraged to use its normal analytical method, thereby simu-
lating the testingof a routine laboratory sampleascloselyaspos-
sible. While the outcome of the analysis may depend on the
choiceofmethod, it alsocouldbeaffectedby theperformanceof
the laboratory equipment or the competence of the analyst.
Usingproficiency testing, those laboratoriesperformingwell can
ensure high standards are maintained and those performing
unsatisfactorily can implement corrective action rapidly. In an
environment inwhichanalytical laboratories compete intensive-
ly for work, proficiency testing provides the means by which
external customers can compare competence in carrying out
specific tests.Togetherwith laboratory accreditation and theuse
of validatedmethods,proficiency tests arean important require-
mentof theEUAdditionalMeasuresDirective93/99/EECapply-
ing to laboratories entrustedwith the official control of food.
aldrin
α
-BHC
β
-BHC
γ
-BHC (lindane)
α
-chlordane (
cis
)
γ
-chlordane (
trans
)
4,4'-DDD
4,4'-DDE
2,4'-DDT
4,4'-DDT
dieldrin
α
-endosulfan (I)
β
-endosulfan (II)
endosulfan sulfate
endrin
heptachlor
heptachlor epoxide (isomer B)
hexachlorobenzene
oxychlordane
*Use of Restek calibrationmixtures by laboratories participating in the FAPAS
program is voluntary and no endorsement of any Restek product has beenmade
by the Central Science Laboratory.To obtain further information regarding the
FAPAS program, or to participate, contact
.
FAPAS®Series5OCPesticideMix1
(19 components)
100µg/mL each in acetone, 1mL/ampul
cat.# 32412 (ea.)
aldrin
10µg/mL
α
-BHC
10
β
-BHC
10
γ
-BHC (lindane)
10
α
-chlordane (
cis
)
10
γ
-chlordane (
trans
)
10
4,4'-DDD
20
4,4'-DDE
20
2,4'-DDT
20
4,4'-DDT
20
dieldrin
20
α
-endosulfan (I)
10
β
-endosulfan (II)
20
endosulfan sulfate
20
endrin
20
heptachlor
10
heptachlor epoxide (isomer B)
10
hexachlorobenzene
10
oxychlordane
10
FAPAS®Series5OCPesticideMix2
(19 components)
In acetone, 1mL/ampul
cat.# 32414 (ea.)
chlorpyriphos
chlorpyriphos-methyl
diazinon
dichlorvos
etrimphos
fenitrothion
malathion
methacriphos
phosphamidon
pirimiphos-methyl
FAPAS®Series9OPPesticideMix1
(10 components)
100µg/mL each in acetone, 1mL/ampul
cat.# 32413 (ea.)
GetMore!
Foods, Flavors&Fragrances
SolutionsOnline
BHT
erucamide slip
vitamin E
Irgafos 168
Irganox 3114
Irganox 1010
Irganox 1076
No data pack available.
ASTMD6042-96CalibrationMix
(7 components)
50µg/mL each in isopropanol, 1mL/ampul
cat.# 31628 (ea.)
OtherAdditivesAvailableFromRestekonaCustomBasis
Similarmethods for extractables in plastic pharmaceutical containers are cited in
theUnited States Pharmacopeia (USP), British Pharmacopoeia (BP), European
Pharmacopoeia (EP), and Japanese Pharmacopoeia (JP). Customersmay also
have formulation-specific or product-specific test mixtures. Please contact us for
a custommixture. Our current inventory of rawmaterials includes these popular
antioxidants.We havemanymore not listed and can obtainmost compounds you
may need.
ASTMMethodD6042-96 (PlasticContainerTesting)
AmericanSociety forTestingandMaterials (ASTM International)
MethodD6042-96—
TestMethod forDeterminationof Phenolic
Antioxidants and Erucamide Slip Additives in Polypropylene
Homopolymer Formulations Using Liquid Chromatography
is a “consensus”or “referee”method used among plasticmanu-
facturers and the pharmaceutical companies that purchase plas-
tic containers. Plastic container manufacturers use this test to
ensure the quality of their product to their pharmaceutical
customers. Pharmaceutical companies also specify this test and
provide their own lists of target compounds and concentration
limits inpurchase agreements.
This test calls for isopropanol extraction,HPLC separation, and
UV detection. Restek offers a variety of reversed phase HPLC
columns suitable for these separations. Restek also designed an
analytical referencematerial to validate this method. This mix-
ture contains the commonantioxidants and slips listed inASTM
D6042-96, alongwithBHT.
Tinuvin P
No data pack available.
ASTMD6042-96 InternalStandardMix
51.8µg/mL in isopropanol, 1mL/ampul
cat.# 31629 (ea.)
• Ethanox 323
• Ethanox 330
• Ethanox 702
• Ethanox 703
• Irganox L06
• Irganox L57
• Irganox L64
• Irganox L109
• Irganox L134
• Irganox L135
• Irganox 1035
• Santanox R
•Ultranox 626
• Vanlube 81
• Vanlube 848
• Vanlube 7723
• Vanlube AZ
• VanlubeNA
• Vanlube PCX
• Vanlube SL
• Vanlube SS
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
Mar 2011
1...,89,90,91,92,93,94,95,96,97,98 100,101,102
Powered by FlippingBook