MRC-2013-Catalog - page 630

630
S
SPECTROPHOTOMETERS
AAS-110A/120A/130A, Flame/Graphite Furnace Atomic Absorption Spectrophotometer
Features:
Innovated rich oxygen air-acetylene flame analysis
technique (AAS-110A)
The patented flame analysis technique adopting
rich oxygen air-acetylene flame as the substitution
for nitrous oxide-acetylene flame for high
temperature element analyses, such as Ca, AI, Ba,
W, Mo, Ti, V, etc. Flame temperature is continuously
adjustable between 2300-2950°C, which makes it
possible to choose the best atomization temperature
for different elements. It features easy operation, low
analysis cost and wide flame AAS analytical range.
Rich oxygen flame will not pollute the environment
and is not harmful to human bodies. It’s a
break-through in flame AAS analysis.
Integrated flame/graphite furnace atomization
system, changeable with flame emission burner
Automatically controlled changeover of the
integrated flame and graphite furnace atomizer
featuring easy operation and time saving
eliminates human labor.
A flame emission burner head can be installed to
perform flame emission analysis to Alkali metals as
K, Na etc. (AAS-110N120A)
Accurate fully automated control system
Automatic multi-lamp turret, automatic
adjustment of lamp current and optimization of
light beam position.
Automatic wavelength scanning and peak
picking
Automatic spectral bandwidth changing
Automatic changeover between flame and graphite
furnace operation, automatic optimization of position
parameters, and automatic ignition.
Reliable fully automatic graphite furnace analysis
Adopting FUZZY-PID and dual curve mode
light-controlled temperature control technique,
temperature auto-correction technique, ensures fast
heating, good temperature reproducibility and high
analytical sensitivity.
The temperature control accuracy is less than 1 %.
Graphite furnace with pneumatic control and pressure
lock ensures constant pressure and reliable contact.
Perfect safety protection measures
Alarm and automatic protection to fuel gas leakage,
abnormal flow, insufficient air pressure and abnormal
flame extinction in flame system;
Alarm and protection function to insufficient carrier gas
and protective gas pressure, insufficient cooling water
supply and over-heating in graphite furnace system.
Advanced and reliable electronic design
Adopting large-scale programmable logic array and
Inter 12C bus technology
European type sockets and AMP adapters with high
reliability to ensure long term reliability of the whole
electronic system.
Easy and practical analysis software
Easy-to-use AAS analysis software is made under
Windows operating system, realizing fast parameter
setting and optimization.
Automatic display of measured data, automatic
calculation and analytical result automatic print out.
Atomic Absorption