restektn07 - page 242

CLINICAL/FORENSICS
31
Capillary GC Columns
Rtx®-20
(fused silica)
(Crossbond
®
80% dimethyl/20% diphenyl polysiloxane)
Rtx®-20
(low/mid-polarityphase; Crossbond®80%dimethyl /20%diphenyl polysiloxane)
• General purpose columns for volatile compounds, flavor compounds, alcoholic beverages.
• Temperature range: -20°C to320°C.
• Equivalent toUSPG28,G32phases.
ID
df (µm)
temp. limits*
15-Meter
30-Meter
60-Meter
105-Meter
0.25mm
0.25
-20 to 300/320°C 10320
$245
10323
$405
10326
$720
10329
$830
0.50
-20 to 290/310°C 10335
$245
10338
$405
10341
$720
10344
$830
1.00
-20 to 280/300°C 10350
$245
10353
$405
10356
$720
10359
$830
0.32mm
0.25
-20 to 300/320°C 10321
$265
10324
$435
10327
$780
10330
$945
0.50
-20 to 290/310°C 10336
$265
10339
$435
10342
$780
10345
$945
1.00
-20 to 280/300°C 10351
$265
10354
$435
10357
$780
10360
$945
0.53mm
0.50
-20 to 260/280°C 10337
$280
10340
$495
10343
$805
1.00
-20 to 260/280°C 10352
$280
10355
$495
10358
$805
*Maximum temperatures listed are for 15- and 30-meter lengths. Longer lengthsmay have a slightly reduced
maximum temperature.
Rtx®-1MS
(fused silica)
(Crossbond
®
100% dimethyl polysiloxane)
ID
df (µm)
temp. limits
15-Meter
30-Meter
0.25mm
0.10
-60 to 330/350°C
11605
$280
11608
$465
0.25
-60 to 330/350°C
11620
$270
11623
$455
0.50
-60 to 330/350°C
11635
$270
11638
$455
0.32mm
0.10
-60 to 330/350°C
11606
$300
11609
$485
0.25
-60 to 330/350°C
11621
$290
11624
$480
0.50
-60 to 330/350°C
11636
$290
11639
$480
0.53mm
1.00
-60 to 320/340°C
11652
$295
11655
$535
1.50
-60 to 310/330°C
11667
$295
11670
$535
didyou
know
?
OurTechnical Service
Department is staffedwith
more than 35 experienced
chemists on rotating shifts
from various departments.
Whether your chromatography
problem is simple or complex,
call Restek’sTechnical Service
Team at 1-800-356-1688 (ext.
4), or contact your Restek rep-
resentative, andwewill do ev-
erythingwe can to help you
find a solution.
Similar
Phases
DB-1, DB-1MS, HP-1, HP-1MS,
Ultra-1, SPB-1, Equity-1,
MDN-1
Similar
Phases
SPB-20
Rxi™-1ms
(fused silica)
(Crossbond
®
100% dimethyl polysiloxane)
Similar
Phases
DB-1, DB-1ms, HP-1, HP-1ms,
Ultra-1, SPB-1, Equity-1
Rxi™-1ms
(nonpolarphase, Crossbond®100%dimethyl polysiloxane)
• General purpose columns for drugs of abuse, essential oils, hydrocarbons, pesticides, PCB congeners
or (e.g.)Aroclor®mixes, sulfur compounds, amines, solvent impurities, simulateddistillation, oxy-
genates, gasoline rangeorganics (GRO), refinery gases.
• Temperature range: -60°C to330/350°C (bleed tested temperature/maximumoperating temperature).
• Lowbleed - improved signal tonoise ratio, for better sensitivity andmass spectral integrity.
• Equivalent toUSPG2phase.
ID
df (µm)
temp. limits
15-Meter
30-Meter
60-Meter
0.25mm 0.25
-60 to 330/350°C 13320
$260
13323
$435
13326
$780
0.50
-60 to 330/350°C 13335
$260
13338
$435
13341
$780
1.00
-60 to 330/350°C 13350
$260
13353
$435
13356
$780
0.32mm 0.25
-60 to 330/350°C 13321
$280
13324
$460
13327
$820
0.50
-60 to 330/350°C 13336
$280
13339
$460
13342
$820
1.00
-60 to 330/350°C 13351
$280
13354
$460
13357
$820
0.53mm 0.50
-60 to 330/350°C 13337
$310
13340
$515
1.00
-60 to 330/350°C 13352
$310
13355
$515
1.50
-60 to 330/350°C 13367
$310
13370
$515
ID
df (µm)
temp. limits
12-Meter
20-Meter
25-Meter
50-Meter
0.18mm 0.18
-60 to 330/350°C
13302
$370
0.20mm 0.33
-60 to 330/350°C 13397
$230
13398
$365
13399
$630
new
column
technology
!
1...,232,233,234,235,236,237,238,239,240,241 243,244,245,246,247,248,249,250,251,252,...344