restektn07 - page 244

CLINICAL/FORENSICS
33
Capillary GC Columns
Rtx®-35
(fused silica)
(Crossbond
®
35% diphenyl/65% dimethyl polysiloxane)
Rtx®-35/Rtx®-35MS
(mid-polarityphase; Crossbond®35%diphenyl /65%dimethyl polysiloxane)
• General purpose columns for organochlorine pesticides, PCB congeners or (e.g.)Aroclor®mixes,
herbicides, pharmaceuticals, sterols, rosin acids, phthalate esters.
• Temperature range: 0°C to320°C.
• Equivalent toUSPG42phase.
ID
df (µm)
temp. limits*
15-Meter
30-Meter
60-Meter
105-Meter
0.25mm
0.25
0 to 320°C
10420
$245
10423
$405
10426
$720
10429
$830
0.50
0 to 310°C
10435
$245
10438
$405
10441
$720
10444
$830
0.32mm
0.25
0 to 320°C
10421
$265
10424
$435
10427
$780
10430
$945
0.50
0 to 310°C
10436
$265
10439
$435
10442
$780
10445
$945
0.53mm
0.50
0 to 300°C
10437
$280
10440
$495
10443
$805
1.00
0 to 290°C
10452
$280
10455
$495
10458
$805
Rtx®-1701
(fused silica)
(Crossbond
®
14% cyanopropylphenyl/86% dimethyl polysiloxane)
Rtx®-1701
(mid-polarityphase; Crossbond®14%cyanopropylphenyl /86%dimethyl polysiloxane)
• General purpose columns for alcohols, oxygenates, PCB congeners or (e.g.)Aroclor®mixes, pesticides.
• Temperature range: -20°C to280°C.
• Equivalent toUSPG46phase.
*Maximum temperatures
listed are for 15- and 30-meter
lengths. Longer lengthsmay
have a slightly reducedmaxi-
mum temperature.
ID
df (µm)
temp. limits*
15-Meter
30-Meter
60-Meter
105-Meter
0.25mm
0.25
-20 to 280°C
12020
$245
12023
$405
12026
$720
12029
$830
0.50
-20 to 270/280°C 12035
$245
12038
$405
12041
$720
12044
$830
0.32mm
0.25
-20 to 280°C
12021
$275
12024
$435
12027
$780
12030
$970
0.50
-20 to 270/280°C 12036
$275
12039
$435
12042
$780
12045
$970
0.53mm
0.50
-20 to 260/270°C 12037
$280
12040
$495
12043
$805
1.00
-20 to 250/270°C 12052
$280
12055
$495
12058
$805
Rtx®-35MS
(fused silica)
(Crossbond
®
35% diphenyl / 65% dimethyl polysiloxane)
ID
df (µm)
temp. limits
15-Meter
30-Meter
0.25mm
0.10
-20 to 320°C
14605
$290
14608
$465
0.25
-20 to 320/340°C
14620
$280
14623
$455
0.32mm
0.10
-20 to 320/340°C
14606
$310
14609
$485
0.25
-20 to 320/340°C
14621
$300
14624
$480
0.53mm
0.50
-20 to 300/320°C
14637
$305
14640
$535
1.00
-20 to 290°C
14652
$305
14655
$535
Similar
Phases
DB-1701, HP-1701, SPB-1701
Similar
Phases
DB-35, HP-35, SPB-35,
SPB-608
Rtx®-35Amine
(fused silica)
(Crossbond
®
35% diphenyl/65% dimethyl polysiloxane)
Rtx®-35Amine
(mid-polarityphase; Crossbond®35%diphenyl /65%dimethylpolysiloxane)
• Application-specific columns for amines andother basic compounds, including alkylamines,
diamines, triamines, ethanolamines, andnitrogen-containingheterocyclics.
• Stable to310°C.
Active basic compounds that otherwise require derivatization can be analyzed on anRtx®-35Amine
column.The tubing surface is chemicallyaltered to reduce tailingof basiccompounds, eliminating the
need for columnpriming.AnRtx-35®Amine column is ideal for awide varietyof basic compounds,
but also is suitable for neutral compounds, adsorptive compoundswithoxygen groups susceptible to
hydrogenbonding,or evenweaklyacidic compounds suchasphenols.EveryRtx®-5Amine column is
tested to ensure that it exceeds the requirements for analyzingppm levelsof amines,without priming,
and to ensure lowbleed atmaximumoperating temperature.
ID
df (µm)
temp. limits
15-Meter
30-Meter
0.25mm
0.50
0 to 290/310°C
11335
$320
11338
$480
1.00
0 to 280/300°C
11350
$320
11353
$480
0.32mm
1.00
0 to 280/300°C
11351
$340
11354
$510
1.50
0 to 270/290°C
11366
$340
11369
$510
0.53mm
1.00
0 to 260/280°C
11352
$355
11355
$565
3.00
0 to 240/260°C
11382
$355
11385
$565
1...,234,235,236,237,238,239,240,241,242,243 245,246,247,248,249,250,251,252,253,254,...344