Figure 2:

A phenyl hexyl column, used under identical conditions, does not provide

adequate retention or selectivity for sulfonamide residue analysis.

Figure 3:

Ultra selective analysis of sulfonamides on a unique Biphenyl column can be used in conjunction with UHPLC for higher

sample throughput.

Figure 1:

Due to their unique selectivity, Biphenyl columns can provide the retention

and separation needed for accurate sulfonamides analysis with simple, MS-friendly

mobile phases.

LC_GN0531

Column:

Ultra Biphenyl (cat.# 9109565); Dimensions: 150 mm x 4.6 mm ID; Particle Size: 5 µm; Pore Size: 100 Å; Temp.: 25 °C;

Sample:

Diluent: 0.1% Formic acid in water; Conc.: 50 µg/mL; Inj. Vol.: 10 µL;

Mobile Phase:

A: 0.1% Formic acid in water, B: 0.1% Formic

acid in acetonitrile;

Gradient (%B):

0 min (10%), 3.0 min (10%), 20.0 min (40%), 21.0 min (40%); Flow: 1.0 mL/min;

Detector:

UV/Vis @

265 nm;

Instrument:

Shimadzu UFLC

XR

.

Peaks

RT (min)

1. Sulfanilamide

4.40

2. Sulfadiazine

10.18

3. Sulfapyridine

10.63

4. Sulfathiazole

10.99

5. Sulfamerazine

11.72

6. Sulfamethazine

12.94

7. Sulfachlorpyridazine 16.08

8. Sulfadoxine

16.42

9. Sulfisoxazole

17.65

10. Sulfadimethoxine

19.47

11. Sulfaquinoxaline

19.86

Strong retention

minimizes matrix

interference for

sulfanilamide.

Unique Biphenyl selectivity

resolves all sulfonamide peaks.

Sulfanilamide is

susceptible to sample

matrix interferences.

Less selectivity results

in coelutions.

For more about the advantages

of USLC® Biphenyl columns, visit

www.restek.com/uslc

LC_GN0533

Column:

Waters XSELECT™ CSH Phenyl-Hexyl; Dimensions: 150 mm x 4.6 mm ID; Particle Size: 5 µm; Temp.: 25 °C;

Sample:

Diluent: 0.1%

Formic acid in water; Conc.: 50 µg/mL; Inj. Vol.: 10 µL;

Mobile Phase:

A: 0.1% Formic acid in water, B: 0.1% Formic acid in acetonitrile;

Gradient (%B):

0 min (10%), 3.0 min (10%), 20.0 min (40%), 21.0 min (40%); Flow: 1.0 mL/min;

Detector:

UV/Vis @ 265 nm;

Instrument:

Shimadzu UFLC

XR

.

Peaks

RT (min)

1. Sulfanilamide

3.07

2. Sulfadiazine

7.15

3. Sulfapyridine

7.43

4. Sulfathiazole

7.96

5. Sulfamerazine

8.54

6. Sulfamethazine

8.53

7. Sulfachlorpyridazine

13.49

8. Sulfadoxine

13.63

9. Sulfisoxazole

15.41

10. Sulfadimethoxine

17.22

11. Sulfaquinoxaline

17.45

LC_GN0532

Column:

Pinnacle® DB Biphenyl (cat.# 9409212); Dimensions: 100 mm x 2.1 mm ID; Particle Size: 1.9 µm;

Pore Size: 140 Å; Temp.: 25 °C;

Sample:

Diluent: 0.1% Formic acid in water; Conc.: 50 µg/mL; Inj. Vol.: 2 µL;

Mobile Phase:

A: 0.1% Formic acid in water, B: 0.1% Formic acid in acetonitrile;

Gradient (%B):

0 min

(5%), 8 min (40%); Flow: 0.4 mL/min;

Detector:

UV/Vis @ 265 nm;

Instrument:

Shimadzu UFLC

XR

.

Peaks

RT (min)

1. Sulfanilamide

1.55

2. Sulfadiazine

3.74

3. Sulfapyridine

4.09

4. Sulfathiazole

4.24

5. Sulfamerazine

4.35

6. Sulfamethazine

4.91

7. Sulfachlorpyridazine

5.87

8. Sulfadoxine

5.99

9. Sulfisoxazole

6.37

10. Sulfadimethoxine

7.14

11. Sulfaquinoxaline

7.40

Ultra Biphenyl Columns

(USP L11)

Physical Characteristics:

Description

cat.#

5 µm Columns

150 mm, 4.6 mm ID

9109565

5 µm Columns

150 mm, 4.6 mm ID (with Trident Inlet Fitting)

9109565-700

particle size: 3 µm or 5 µm, spherical

pore size: 100 Å

carbon load: 15%

endcap: fully endcapped

pH range: 2.5 to 8

temperature limit: 80 °C

ordering

note

For guard cartridges for these columns, visit our

website at

www.restek.com

Pinnacle® DB Biphenyl Columns

(USP L11)

Physical Characteristics:

Description

cat.#

1.9 µm Columns

100 mm, 2.1 mm ID

9409212

particle size: 1.9 µm, 3 µm, or 5 µm,

spherical

pore size: 140 Å

carbon load: 8%

endcap: yes

pH range: 2.5 to 8

temperature limit: 80 °C