Figure 2

Increase reproducibility and sample integrity with a PTV

On-Column liner.

1

3

2

1. nitroglycerin

500ng/mL

2. 1,3,5-trinitrotoluene 100ng/mL

3. 2,4,6-trinitrobenzene 100ng/mL

GC_EV01041

Figure 3

Improve sensitivity with larger injection volumes using a PTV On-Column liner.

Column:

Rtx

®

-TNT1, 6m, 0.53mm ID, 0.5µm

(cat.# 562719)

with 5m x 0.53mm IP guard tubing

(cat.# 10045),

connected using PTV On-Column liner

(cat.# 24976)

Sample:

8095 Calibration Mix A and

8095 Calibration Mix B diluted in acetonitrile

Inj.:

PTV injection port

splitless (15mL/min. @ 0.35 min.)

Inj. temp.:

55°C to 285°C @ 10°C/min.

(hold 10 min.)

Carrier gas:

helium, constant flow

Linear velocity: 60cm/sec. @ 300°C

Oven temp.:

50°C to 280°C @ 10°C/min.

(hold 10 min.)

Det.:

µECD @ 300°C, nitrogen make-up

gas @ 60mL/min.

GC_EV01042A-C

Injection Volume

100µl

50µl

5µl

TNT

Product Listing

0.9986 (TNB) and 0.9997 (TNT) were obtained.

Note that a linear response is maintained—even

for high injection volumes.

Why pay for two injection ports when a simple

liner change gives you the benefits of having two

inlets in one? Using a PTV On-Column liner saves

you money and gives you flexibility in the lab. Use

this liner and reliably perform true cold on-col-

umn injections with your PTV injection port.

PTV Liners for Agilent GCs

ID* x OD & Length

qty.

cat.#

price

PTV On-Column Liner

1.7mm x 3.0mm x 71mm

ea.

24976

1.7mm x 3.0mm x 71mm 5-pk.

24977

*Nominal ID at syringe needle expulsion point.

nitroglycerin

TNT & TNB

TNB

Absolute area reproducibility improves for all compounds, and sensitive compound

responses improve dramatically because of the lack of contact with the injection port.

nitroglycerin:

Absolute Area % RSD = 2.6% • Relative Area % RSD = 1.6%

TNT:

Absolute Area % RSD = 1.5% • Relative Area % RSD = 1.4%

Nitroglycerin response and reproducibility

improve through on-column injection.

Five repetitions

of a 100/500ppbv EPA

8095 Explosives

Standard Mix (A&B)

Column: Rxi

®

-5ms, 6m, 0.53mm ID, 0.5µm (cat.# 563153) with 5m x 0.53mm IP guard tubing (cat.# 10045),

connected using PTV On-Column liner (cat.# 24976); Sample: 8095 Calibration Mix A and 8095 Calibration

Mix B diluted in acetonitrile; Inj.: PTV injection port splitless (15mL/min. @ 0.35 min.); Inj. temp.: 55°C to

285°C @ 10°C/min. (hold 10 min.); Carrier gas: helium, constant flow; Linear velocity: 60cm/sec. @ 300°C;

Oven temp.: 50°C to 280°C @ 10°C/min. (hold 10 min.); Det.: µECD @ 300°C, nitrogen make-up gas @

60mL/min.