• 7 •

Figure 2

Use an Rxi®-5Sil MS column to easily resolve a broad

range of pesticide chemistries in a single run (500pg).

2008 vol. 3

values less than 0.990, such as acephate, omethoate,

and dicofol, show a more linear response when ana-

lyzed in matrix. As shown in Figure 1, the Rxi®-5Sil

MS column is also highly inert, producing excellent

peak shape even for difficult compounds such as

acephate. The linearity, sensitivity, and inertness

demonstrated here, make the Rxi®-5Sil MS column

ideal for more accurate low level quantification of

active compounds.

Low Bleed, High Selectivitity

Another crucial characteristic for multiresidue

pesticide methods is column bleed. Minimizing

bleed is critical in preventing interference with

target compounds, even in SIM analysis, as some

compounds may share ions and have similar bleed

spectra. As shown in the TIC chromatogram in

Figure 2, the ultra-low bleed of the Rxi®-5Sil MS

column allows full scan analysis with minimal

interference from column bleed. The Rxi®-5Sil MS

column provides excellent separation for the wide

range of chemistries tested and the column is also

selective enough to easily separate isomers, such as

permethrin I and II.

In summary, many of the difficulties associated

with multiresidue methods are simplified by using

the Rxi®-5Sil MS column. Its outstanding inert-

ness, low bleed at high temperatures, and unique

selectivity provide a robust capillary column with

the sensitivity and longevity needed to address the

tough challenges inherent to low level multiresidue

pesticide analysis.

Figure 1

Outstanding peak symmetry for active compounds

demonstrates column inertness (500pg).

1. methamidophos

2. dichlorvos

3. bromonitrobenzene (IS)

4. mevinphos

5. acephate

6.

o

-phenylphenol

7. omethoate

8. dimethoate

9. pentachloronitrobenzene (IS)

10. diazinon

11. chlorothalonil

12. vinclozolin

Column:

Rxi

®

-5Sil MS, 30m, 0.25mm ID, 0.25µm (cat.# 13623),

with 5m x 0.25mm ID Rxi

®

deactivated guard tubing (cat.# 10029)

Instrument:

PerkinElmer Clarus 500 GC/MS

Sample:

1ppm each compound (custom mixes)

1ppm triphenylphosphate (cat.# 32281)

1ppm 1-bromo-2-nitrobenzene (cat.# 32279)

1ppm pentachloronitrobenzene (cat.# 32091)

Inj.:

0.5µL splitless (hold 1 min.),

PSS Drilled Uniliner

®

(hole near bottom) inlet liner (cat.# 22989)

Inj. temp.:

250°C

Carrier gas:

helium, constant flow

Linear velocity:

32cm/sec. @ 90°C

Oven temp.:

90°C (hold 1 min.) to 310°C @ 10°C/min. (hold 5 min.)

Det.:

MS

Transfer line temp: 300°C

Scan range:

50-350amu

Ionization:

EI

Mode:

scan

GC_EV01034

GC_EV01036

1. acephate

13. carbaryl

14. metalaxyl

15. dichlofluanid

16. malathion

17. thiabendazole

18. captan

19. folpet

20. imazalil

21. myclobutanil

22. endrin

23. fenhexamid

24. 4,4’-DDT

25. propargite

26. triphenylphosphate (IS)

27. iprodione

28. bifenthrin

29. fenpropathrin

30. dicofol

31. permethrin I

32. permethrin II

33. deltamethrin

* septum bleed

Product Listing

Rxi®-5Sil MS Columns (fused silica)

(Crossbond

®

, selectivity close to 5% diphenyl/95% dimethyl polysiloxane)

ID df (µm)

temp. limits

length cat. #

price

0.25mm 0.25 -60 to 330/350°C 30-Meter 13623

Rxi® Guard/Retention Gap Column

Nominal ID

Nominal OD

5-Meter

0.32mm

0.45 ± 0.04mm 10039

PSS Liners for PerkinElmer GCs

ID* x OD & Length (mm)

qty.

cat.#

price

PSS Drilled Uniliner (hole near bottom)

20mm x 4.0mm x 86.2mm 5-pk.

22989

The inertness of the

Rxi®-5Sil MS column

ensures linear performance

down to 10pg on-column,

allowing more accurate

low level quantification.

See Figure 2 for conditions.