TO-Can

Air

Monitoring Canisters

Optimized for EPA Methods T0-14 and TO-15

US Environmental Protection Agency (EPA)

Compendium of Air Methods TO-14 and TO-15 reg-

ulate the collection, storage, and analysis of volatile

organic compounds (VOCs) using treated air sam-

pling canisters. Restek now offers a complete line

of TO-Can

canisters (SUMMA

®

can equivalent),

which are electropolished using a proprietary

by David Shelow, Air Monitoring Innovations Chemist

process and extensively cleaned using an ultrasonic

method. This ensures a high-quality, passivated sur-

face to maintain stability of the TO-14/TO-15 com-

pounds during storage. Also, the design of the

frame surrounding the electropolished canister

eliminates the need for weld marks on the sphere,

thereby preventing active sites on the canisters. And

the addition of a Parker Hannifin metal-to-metal

diaphragm valve further improves the performance

of the canister.

To collect VOCs in ambient air, the TO-Can

canis-

ters should be pre-cleaned and pre-evacuated prior

to being sent to the field. Once in the field, the sam-

ple is drawn through a sampling train that will reg-

ulate the rate and duration of sampling. The

TO-Can

canister is then sent to an analytical labo-

ratory for analysis. In the laboratory, a known

amount of sample is drawn from the canister and

concentrated onto a concentrating trap. The sample

is analyzed according to Method TO-14/TO-15, typi-

cally using a 60m, 0.32mm ID, 1.0µm Rtx

®

-1 capil-

lary column and a GC/MS system.

60m, 0.32mm ID, 1.0µm Rtx-1 (cat.# 10157). 200mL injection of a 10ppbv TO-15 standard (cat.# 34436), made in TO-Can canister and humidified to 70% RH.

Concentrator:

Nutech

3550 Preconcentrator; 200mL of sample concentrated at 160°C, thermally desorbed at 150°C, and cryofocused at 185°C.

Oven temp.:

30°C (hold 4 min.) to 175°C @ 9°C/min. to

220°C @ 40°C/min.

Carrier gas:

helium @1.2mL/min.

Det.:

Agilent 5971 MS, scan range 35-265amu

(For peak identifications, request Applications Note #59189.)

Chromatogram courtesy of Gina Maio at Severn Trent Laboratories, Inc., Burlington, VT.

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 min.

Figure 1

TO-Can

canisters ensure excellent recovery for TO-14/TO-15 compounds, even after 14 days of storage.

To show the stability of these canisters, and how

well they meet the holding time criteria for Methods

TO-14/15, a 62-component TO-15 standard

(10ppbv) was injected into a TO-Can

canister and

humidified to 70% relative humidity. The standard

was analyzed on day 1, day 7, and day 14. The TO-

Can

canister demonstrated excellent stability for

these polar and non-polar compounds. The result-

ing analysis shows excellent stability after 14 days

storage of the compounds (Figure 1).

TO-Can

Canisters

size (L)

cat.#

1

24150

3

24152

6

24153

15

24154

TO-Can

Canisters with

Vacuum/Pressure Gauge

size (L)

cat.#

1

24155

3

24156

6

24157

15

24158

for

more

info

including complete stability test data,

request Applications Note #59189.

1

3

4

5

6

7

8

9/10

11

12

13

14

15

16

17

18

19

20

21

22/23 24

25

26

27

28

29

30

31

32

33

34

35/36

37

38

39

40

41 42

43 44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60 61

62

63

BFB

GC_EV00379

Restek also offers SilcoCan

canisters for

the analysis of low-level sulfur compounds.

For more information on SilcoCan

canisters, request Fast Facts #59311.

SUMMA

®

can equivalent

Excellent recovery—even after

14 days of storage

2