Table of Contents Table of Contents
Previous Page  252 / 298 Next Page
Information
Show Menu
Previous Page 252 / 298 Next Page
Page Background

w/ data pack

w/ data pack

• 10 •

www.restekcorp.com

By Katia May, Ph.D., Senior R&D Chemist

Forensic Ethanol Standards

0.08g/dL standard supports new federal blood alcohol limit.

0.4g/dL standard supports autopsy of alcohol-related deaths.

0.05g/dL standard supports limits for long-haul truck drivers.

Many other concentrations available.

The United States’ blood alcohol limit has been reduced to 0.08g/dL. Consistent with our commitment to sup-

port police and crime laboratories, we are introducing three new reference mixes to meet current needs.

Restek Forensic Ethanol Standards are NIST traceable. Data packs included.

Carbazole

No interference with OLC 03.2 target compounds.

Many laboratories following US EPA Contract

Laboratory Program OLC 03.2 Statement of Work

also analyze for carbazole. Most carbazole reference

solutions are in methanol, but certain target com-

pounds in OLC 03.2 SOW react with methanol (e.g.,

benzaldehyde, atrazine). We prepare our new refer-

ence standard in methanol-free methylene chloride,

to prevent reactions when it is added to OLC 03.2

Semivolatile MegaMix

(cat.# 31812).

ε

-Caprolactam

A precursor in the synthesis of nylon-6,

ε

-caprolac-

tam is one of the most heavily and widely used

chemical intermediates—more than 9.5 billion

pounds each year, worldwide. Environmental con-

tamination should be anticipated, and caprolactam

has toxic effects. This solution is suitable for moni-

toring

ε

-caprolactam.

Glyphosate and AMPA (glyphosate

metabolite)

Glyphosate packaged in two volumes, to meet

varied requirements.

Glyphosate at 1000µg/mL concentration, for

more analyses per ampul.

Glyphosate (N-phosphonomethyl glycine) is a broad-

spectrum post-emergence herbicide used in agricul-

ture and forestry and for aquatic weed control. A

weak organic acid, glyphosate usually is formulated

as the isopropylamine salt to increase solubility. Our

new mix is suitable for EPA Method 547, for identify-

ing and measuring glyphosate in drinking water

(HPLC with fluorescence detection and post-column

derivatization).

Aminomethylphosphonic acid—AMPA—is the pri-

mary degradation product of glyphosate in plants,

soil, and water. The chemical structures of the two

compounds are very similar, and they have similar

toxicological profiles. The health base value for

glyphosate also applies to AMPA, and to glyphosate

and AMPA in combination.

PCB-Free Transformer Oil

Convenient 5mL and 50mL packaging.

Use and disposal of all mineral oil-filled transform-

ers have been subject to federal regulation since

1978. Traditionally, transformer oil is tested for poly-

chlorinated biphenyls (PCBs) contamination by GC.

Acrolein & Acrylonitrile

High concentrations:

acrolein: 10,000µg/mL

acrylonitrile: 2,000µg/mL

acrolein/acrylonitrile: 2,000µg/mL.

Acrolein and acrylonitrile are monomers used in

manufacturing polyacrylamide and other acrylic

polymers. These new mixes are suitable for use with

US EPA Method 603, or other methods for testing

water samples for acrylonitrile and acrolein by purge

& trap GC. They have a shelf life of 2-3 months.

Forensic ethanol solutions

w/data pack

5-pk.

1mL/ampul

10-pk.

1mL/ampul

ea.

5mL/ampul

ea.

20mL/ampul

0.05g/dL forensic ethanol solution

36257

36259

36258

36260

0.08g/dL forensic ethanol solution

36262

36264

36263

36265

0.4g/dL forensic ethanol solution

36266

36268

36267

36269

carbazole

Carbazole

1,000µg/mL in methylene chloride (methanol free), 1mL/ampul

Each

5-pk.

10-pk.

31836

31836-510

w/data pack

31836-500

31836-520

31936

ε

-caprolactam

ε

-Caprolactam

2,000µg/mL in methylene chloride (methanol free), 1mL/ampul

Each

5-pk.

10-pk.

31833

31833-510

w/data pack

31833-500

31833-520

31933

glyphosate

Glyphosate

Each

5-pk.

10-pk.

1,000µg/mL in DI water, 1mL/ampul

32426

32426-510

32426-500

32426-520

32526

1,000µg/mL in DI water, 5mL/ampul

32427

32427-510

32427-500

32427-520

32527

aminomethyl phosphonic acid (AMPA)

AMPA (glyphosate metabolite)

100µg/mL in DI water, 1mL/ampul

Each

5-pk.

10-pk.

32428

32428-510

w/data pack

32428-500

32428-520

32528

PCB-Free transformer oil

PCB-Free Transformer Oil

Neat

5mL

50mL

32424

32425

acrolein

Acrolein

10,000µg/mL in P&T methanol, 1mL/ampul

Each

5-pk.

10-pk.

30499

30499-510

w/data pack

30499-500

30499-520

30599

acrolein

acrylonitrile

Acrolein/Acrylonitrile

2,000µg/mL in P&T methanol, 1mL/ampul

Each

5-pk.

10-pk.

30600

30600-510

w/data pack

30600-500

30600-520

30700

New Analytical Reference Materials

For Forensic and Environmental Analyses

acrylonitrile

Acrylonitrile

2,000µg/mL in P&T methanol, 1mL/ampul

Each

5-pk.

10-pk.

30246

30246-510

w/data pack

30246-500

30246-520

30346

acetaldehyde

acetone

acetonitrile

ethanol (NIST certified value)

ethyl acetate

isopropanol

methanol

methyl ethyl ketone

Blood Alcohol Mix Resolution

Control Standard

0.100g/dL each in water, 1mL/ampul

Each w/data pack

36256

Forensic Reference

Materials

Environmental Reference

Materials