Table of Contents Table of Contents
Previous Page  251 / 298 Next Page
Information
Show Menu
Previous Page 251 / 298 Next Page
Page Background

• 9 •

www.restekcorp.com

Rtx®-624 Columns (fused silica)

(Crossbond

®

6% cyanopropylphenyl/94% dimethyl polysiloxane)

benzene

bromodichloromethane

bromoform

carbon tetrachloride

chlorobenzene

2-chloroethyl vinyl ether

chloroform

dibromochloromethane

1,2-dichlorobenzene

1,3-dichlorobenzene

1,4-dichlorobenzene

1,1-dichloroethane

1,2-dichloroethane

1,1-dichloroethylene

trans

-1,2-dichloroethylene

1,2-dichloropropane

cis

-1,3-dichloropropylene

trans

-1,3-dichloropropylene

ethylbenzene

methylene chloride

(dichloromethane)

1,1,2,2-tetrachloroethane

tetrachloroethylene

toluene

1,1,1-trichloroethane

1,1,2-trichloroethane

trichloroethylene

Volatiles MegaMix™,

EPA Method 624

(26 components)

2,000µg/mL each in P&T methanol, 1mL/ampul

Each

5-pk.

10-pk.

30497

30497-510

w/data pack

30497-500

30497-520

30597

bromomethane

chloroethane

chloromethane

trichlorofluoromethane

vinyl chloride

2,000µg/mL each in P&T methanol, 1mL/ampul

Each

5-pk.

10-pk.

30020

30020-510

w/data pack

30020-500

30020-520

30120

4-bromofluorobenzene

fluorobenzene

pentafluorobenzene

624 Surrogate Standard Mix

2,000µg/mL each in P&T methanol, 1mL/ampul

Each

5-pk.

10-pk.

30243

30243-510

w/data pack

30243-500

30243-520

30343

1,500µg/mL each in P&T methanol, 1mL/ampul

Each

5-pk.

10-pk.

30023

30023-510

w/data pack

30023-500

30023-520

30123

MegaMix™ Reference Mixes

For US EPA Methods

Volatiles: 524.2, 624, 8260,

OLC 03.2, OLM 04.2, 502.2

Semivolatiles: 525.2, 625, 8270,

OLC 03.2, OLM 04.2

mix

it

up!

Restek’s

MegaMix

Standards

Fewest mixes needed for calibration or matrix spike

Maximum stability

Most commonly analyzed compounds:

• 8260—76 volatile compounds in 1 mix

gases and ketones in separate mixes, for maximum stability

• 8270—76 semivolatile compounds in 1 mix

• Appendix IX—59 semivolatile compounds in 3 mixes

• 524—73 volatile compounds in 1 mix

• 525—90 semivolatile compounds in 5 mixes

• 625—54 semivolatile compounds in 1 mix

• CLP 03.2 (volatiles and semivolatiles)

• CLP 04.2 (volatiles and semivolatiles)

For details, visit our website at

www.restekcorp.com

Our reference materials for the method include the

recommended surrogates (cat.# 30243). The

method also requires 3 or more internal standards

that are similar in analytical behavior to the target

compounds. Our internal standard mix (cat.#

30023) includes recommended compounds and sat-

isfies this requirement.

Based on a cyanopropylphenyl/dimethyl polysiloxane

phase, our Rtx

®

-624 column has unique polarity,

and provides excellent separation of the target com-

pounds. By using a short, narrow bore column

(40m x 0.18mm ID, 1.0µm phase) we reduced

analyses time and improved resolution. This particu-

lar column configuration also eliminates non-target

interference with target compounds. Figure 1 shows

an analyses of all Method 624 target compounds on

a 40m x 0.18mm ID Rtx

®

-624 column. Total cycle

time is 17 minutes, which matches the cycle time for

the purge and trap concentrator.

By using a 40m x 0.18mm ID, 1.0µm Rtx

®

-624 col-

umn and Restek’s convenient, carefully formulated

reference materials, you can obtain rapid analyses

and accurate data. These practical advantages make

Restek the best source for materials for EPA Method

624, and for wastewater volatiles analyses in general.

624 Calibration Mix #1

bromochloromethane

2-bromo-1-chloropropane

1,4-dichlorobutane

624 Internal Standard Mix

Stability of 2-Chloroethyl vinyl ether

2-Chloroethyl vinyl ether is stable in neutral pH and in slightly basic solutions. If the solution is slightly acidic, the

analyte will rapidly decompose. Restek specially prepares stable individual solutions of 2-chloroethyl vinyl ether in

neutral purge and trap methanol. These solutions are very stable and can be diluted without problems, using pure,

neutral, P&T grade methanol. Be careful when combining these solutions with other calibration materials - some

solutions can contain trace acidic impurities that will cause rapid decomposition of 2-chloroethyl vinyl ether. Be

especially cautious of calibration mixtures that contain high concentrations or a large number of chlorinated target

compounds; these often will contain sufficient trace HCl to cause stability problems with 2-chloroethyl vinyl ether.

Tech

Tip

!

HOT

ID df (µm)

temp. limits

20-Meter

40-Meter

0.18mm 1.00 -20 to 240°C

40924

40925

ID df (µm)

temp. limits

30-Meter

60-Meter

75-Meter

105-Meter

0.25mm 1.40

-20 to 240°C 10968

10969

0.32mm 1.80

-20 to 240°C 10970

10972

0.45mm 2.55

-20 to 240°C

10982

0.53mm 3.00

-20 to 240°C 10971

10973

10974

10975