![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0251.jpg)
• 9 •
www.restekcorp.comRtx®-624 Columns (fused silica)
(Crossbond
®
6% cyanopropylphenyl/94% dimethyl polysiloxane)
benzene
bromodichloromethane
bromoform
carbon tetrachloride
chlorobenzene
2-chloroethyl vinyl ether
chloroform
dibromochloromethane
1,2-dichlorobenzene
1,3-dichlorobenzene
1,4-dichlorobenzene
1,1-dichloroethane
1,2-dichloroethane
1,1-dichloroethylene
trans
-1,2-dichloroethylene
1,2-dichloropropane
cis
-1,3-dichloropropylene
trans
-1,3-dichloropropylene
ethylbenzene
methylene chloride
(dichloromethane)
1,1,2,2-tetrachloroethane
tetrachloroethylene
toluene
1,1,1-trichloroethane
1,1,2-trichloroethane
trichloroethylene
Volatiles MegaMix™,
EPA Method 624
(26 components)
2,000µg/mL each in P&T methanol, 1mL/ampul
Each
5-pk.
10-pk.
30497
30497-510
—
w/data pack
30497-500
30497-520
30597
bromomethane
chloroethane
chloromethane
trichlorofluoromethane
vinyl chloride
2,000µg/mL each in P&T methanol, 1mL/ampul
Each
5-pk.
10-pk.
30020
30020-510
—
w/data pack
30020-500
30020-520
30120
4-bromofluorobenzene
fluorobenzene
pentafluorobenzene
624 Surrogate Standard Mix
2,000µg/mL each in P&T methanol, 1mL/ampul
Each
5-pk.
10-pk.
30243
30243-510
—
w/data pack
30243-500
30243-520
30343
1,500µg/mL each in P&T methanol, 1mL/ampul
Each
5-pk.
10-pk.
30023
30023-510
—
w/data pack
30023-500
30023-520
30123
MegaMix™ Reference Mixes
For US EPA Methods
Volatiles: 524.2, 624, 8260,
OLC 03.2, OLM 04.2, 502.2
Semivolatiles: 525.2, 625, 8270,
OLC 03.2, OLM 04.2
mix
it
up!
Restek’s
MegaMix
™
Standards
✔
Fewest mixes needed for calibration or matrix spike
✔
Maximum stability
✔
Most commonly analyzed compounds:
• 8260—76 volatile compounds in 1 mix
gases and ketones in separate mixes, for maximum stability
• 8270—76 semivolatile compounds in 1 mix
• Appendix IX—59 semivolatile compounds in 3 mixes
• 524—73 volatile compounds in 1 mix
• 525—90 semivolatile compounds in 5 mixes
• 625—54 semivolatile compounds in 1 mix
• CLP 03.2 (volatiles and semivolatiles)
• CLP 04.2 (volatiles and semivolatiles)
For details, visit our website at
www.restekcorp.comOur reference materials for the method include the
recommended surrogates (cat.# 30243). The
method also requires 3 or more internal standards
that are similar in analytical behavior to the target
compounds. Our internal standard mix (cat.#
30023) includes recommended compounds and sat-
isfies this requirement.
Based on a cyanopropylphenyl/dimethyl polysiloxane
phase, our Rtx
®
-624 column has unique polarity,
and provides excellent separation of the target com-
pounds. By using a short, narrow bore column
(40m x 0.18mm ID, 1.0µm phase) we reduced
analyses time and improved resolution. This particu-
lar column configuration also eliminates non-target
interference with target compounds. Figure 1 shows
an analyses of all Method 624 target compounds on
a 40m x 0.18mm ID Rtx
®
-624 column. Total cycle
time is 17 minutes, which matches the cycle time for
the purge and trap concentrator.
By using a 40m x 0.18mm ID, 1.0µm Rtx
®
-624 col-
umn and Restek’s convenient, carefully formulated
reference materials, you can obtain rapid analyses
and accurate data. These practical advantages make
Restek the best source for materials for EPA Method
624, and for wastewater volatiles analyses in general.
624 Calibration Mix #1
bromochloromethane
2-bromo-1-chloropropane
1,4-dichlorobutane
624 Internal Standard Mix
Stability of 2-Chloroethyl vinyl ether
2-Chloroethyl vinyl ether is stable in neutral pH and in slightly basic solutions. If the solution is slightly acidic, the
analyte will rapidly decompose. Restek specially prepares stable individual solutions of 2-chloroethyl vinyl ether in
neutral purge and trap methanol. These solutions are very stable and can be diluted without problems, using pure,
neutral, P&T grade methanol. Be careful when combining these solutions with other calibration materials - some
solutions can contain trace acidic impurities that will cause rapid decomposition of 2-chloroethyl vinyl ether. Be
especially cautious of calibration mixtures that contain high concentrations or a large number of chlorinated target
compounds; these often will contain sufficient trace HCl to cause stability problems with 2-chloroethyl vinyl ether.
Tech
Tip
!
HOT
ID df (µm)
temp. limits
20-Meter
40-Meter
0.18mm 1.00 -20 to 240°C
40924
40925
ID df (µm)
temp. limits
30-Meter
60-Meter
75-Meter
105-Meter
0.25mm 1.40
-20 to 240°C 10968
10969
0.32mm 1.80
-20 to 240°C 10970
10972
0.45mm 2.55
-20 to 240°C
10982
0.53mm 3.00
-20 to 240°C 10971
10973
10974
10975