Table of Contents Table of Contents
Previous Page  247 / 298 Next Page
Information
Show Menu
Previous Page 247 / 298 Next Page
Page Background www.restekcorp.com

• 5 •

Inert PEEK

®

Tubing

• Replaces stainless steel, titanium, Teflon

®

and Tefzel

®

tubing.

• Use to 7,000psi.

Description

Color Code

qty.

cat.#

price

PEEK

®

Tubing,

1

/

16

" OD x 0.0025" ID x 1m

natural

3-pk.

25320

PEEK

®

Tubing,

1

/

16

" OD x 0.005" ID x 3m

red stripe

ea.

25065

PEEK

®

Tubing,

1

/

16

" OD x 0.007" ID x 3m

yellow stripe

ea.

25066

PEEK

®

Tubing,

1

/

16

" OD x 0.010" ID x 3m

blue stripe

ea.

25067

PEEK

®

Tubing,

1

/

16

" OD x 0.020" ID x 3m

orange stripe

ea.

25068

HPLC Stainless Steel Capillary Tubing

• 316 grade stainless steel.

• Precise pre-cut lengths.

Length

ID

OD

qty.

cat.#

price

5cm

0.005"

1

/

16

"

3-pk.

25240

10cm

0.005"

1

/

16

"

3-pk.

25241

20cm

0.005"

1

/

16

"

3-pk.

25242

30cm

0.005"

1

/

16

"

3-pk.

25243

5cm

0.007"

1

/

16

"

3-pk.

25244

10cm

0.007"

1

/

16

"

3-pk.

25245

20cm

0.007"

1

/

16

"

3-pk.

25246

30cm

0.007"

1

/

16

"

3-pk.

25247

5cm

0.010"

1

/

16

"

3-pk.

25248

10cm

0.010"

1

/

16

"

3-pk.

25249

20cm

0.010"

1

/

16

"

3-pk.

25250

30cm

0.010"

1

/

16

"

3-pk.

25251

5cm

0.020"

1

/

16

"

3-pk.

25252

10cm

0.020"

1

/

16

"

3-pk.

25253

20cm

0.020"

1

/

16

"

3-pk.

25254

30cm

0.020"

1

/

16

"

3-pk.

25255

Description

qty.

cat.# price

Clean-Cut

Tubing Cutter

ea.

25069

Replacement Blade for Clean-

Cut

Cutter

ea.

25070

Clean-Cut

Tubing Cutter

• Burr-free, perpendicular cuts that will not

distort tubing OD.

• Use on PEEK

®

, Teflon

®

, Tefzel

®

, other poly-

meric tubing.

Historically, 2,4-D and Silvex mixtures have com-

prised many herbicide formulations, and we devel-

oped a reference mix for laboratories that analyze

only these two compounds. Similarly, we offer an

individual solution of dalapon, a herbicide not listed

in Method 555, but included in more general

Method 8321A. We offer 1,4-dichlorobenzene as an

internal standard for this assay. All of our new herbi-

Analyze Underivitized Chlorophenoxyacid Herbicides

by HPLC

(cont. from pg. 3)

1.0mm ID

2.1mm ID

3.2mm ID

4.6mm ID

Length

cat.# price

cat.#

price

cat.# price

cat.#

price

3µm Columns

30mm 9178331

9178332

9178333

9178335

50mm 9178351

9178352

9178353

9178355

100mm 9178311

9178312

9178313

9178315

5µm Columns

30mm 9178531

9178532

9178533

9178535

50mm 9178551

9178552

9178553

9178555

100mm 9178511

9178512

9178513

9178515

150mm 9178561

9178562

9178563

9178565

200mm 9178521

9178522

9178523

9178525

250mm 9178571

9178572

9178573

9178575

Ultra Aqueous C18 HPLC Columns (USP L1)

particle size: 3 or 5µm, spherical; not end-capped; pore size: 100Å; pH range: 2.5 to 7.5; temperature limit: 80°C

cides mixes are prepared in acetonitrile, as appro-

priate for HPLC applications, at a convenient con-

centration of 1000µg/mL.

If your analyses include monitoring chlorophenoxy-

acid herbicides, an Ultra Aqueous C18 column and

our new reference mixes will help you obtain the

most accurate data.

2,4-dichlorophenoxyacetic acid

2,4,5-TP (Silvex)

Chlorinated Acid Herbicide Mix

1,000µg/mL each in acetonitrile, 1mL/ampul

Each

5-pk.

10-pk.

32429

32429-510

w/data pack

32429-500

32429-520

32529

dalapon

Dalapon

1,000µg/mL in acetonitrile, 1mL/ampul

Each

5-pk.

10-pk.

32432

32432-510

w/data pack

32432-500

32432-520

32532

1,4-dichlorobenzene

1,4-Dichlorobenzene

1,000µg/mL in acetonitrile, 1mL/ampul

Each

5-pk.

10-pk.

30498

30498-510

w/data pack

30498-500

30498-520

30598

5-hydroxydicamba

5-Hydroxydicamba

100µg/mL in acetone:water (90:10), 5mL/ampul

Each

MET-346A

Environmental

HPLC:

Applications,

Columns,

Reference

Materials

(lit. cat.# 59741)

Restek HPLC columns

support environmental

HPLC applications with

rapid analysis times

and effective resolu-

tion of target analytes. Sample turn-around can be

50% faster, or more, than with alternative columns.

Applications in this 8-page publication include polyaro-

matic hydrocarbons, carbamates, phenoxyacid her-

bicides, explosives, and carbonyls. Analytical refer-

ence materials and solid phase extraction sample

clean-up products also are listed.