Table of Contents Table of Contents
Previous Page  218 / 298 Next Page
Information
Show Menu
Previous Page 218 / 298 Next Page
Page Background

Minimize Adsorption of

Active Analytes...

Continued from page 12

• 13 •

www.restekcorp.com

2003

Volume 2

800-356-1688

Hole makes direct injection

possible with EPC-equipped

Agilent 6890 GCs!

deactivated

all liners are

Drilled Uniliner

®

Use a Drilled Uniliner

®

inlet liner with

the hole near the bottom if com-

pounds of interest will be affected by

a tailing solvent peak. Use a Drilled

Uniliner

®

inlet liner with the hole near

the top when compounds of interest

elute away from the solvent peak,

when sensitivity is critical, or when

the sample solvent is water.

Siltek

Deactivation—The Next Generation of Surface Passivation

• Maximizes the inertness of the sample pathway.

• Minimizes breakdown.

• Low bleed.

• Thermally stable.

• “Clean and green”—manufactured without the use of harmful organic solvents.

Restek offers the next generation of deactivation. The Siltek

deactivation process (patent pending) produces a

highly inert glass surface, which features high temperature stability, extreme durability, and low bleed. Try

Siltek

liners, guard columns, wool, and connectors for better recovery of sample analytes.

For Siltek

inlet liners, add the corresponding suffix number to the liner catalog number.

Siltek

with

Siltek

with

qty.

Siltek

Siltek

wool

CarboFrit

each

-214.1

addl. cost

-213.1

addl. cost

-216.1

addl. cost

5-pk.

-214.5

addl. cost

-213.5

addl. cost

-216.5

addl. cost

25-pk.

-214.25

addl. cost

-213.25

addl. cost

-216.25

addl. cost

Under the same conditions, a Drilled Uniliner

®

with the hole near the top produces a solvent

peak with a small tail (Figure 3c). This is

because solvent remaining within the liner,

between the hole and the column entrance, is

not swept out of the injection port when the

injector goes into the split mode. Consequently,

we recommend this liner for analyses in which

the analytes would not be affected by a solvent

tail, such as chlorinated pesticide analysis. A

Drilled Uniliner

®

with the hole near the top

will provide the best sensitivity, and is recom-

mended when sensitivity is paramount. A

Drilled Uniliner

®

with the hole near the top

also has exhibited excellent reproducibility for

analysis of glycols in water.

For accurate, reproducible, problem-free

split/splitless injections, we recommend you use

a Drilled Uniliner

®

inlet liner—and connect it

to a Restek capillary GC column.

References

1.

Operating Hints for Using Split/Splitless Injectors

Restek Corporation, Bellefonte, PA, 36pp, 2002.

(Reference free on request: cat.# 59880A)

2.

Higher Responses for Chlorinated Pesticides, Using a

Drilled Uniliner

®

GC Inlet Liner and Rtx

®

-

CLPesticides Columns

Restek Corporation, Bellefonte,

PA, 4pp, 2003.

(Reference free on request: cat.# 59487.)

New / Recent Literature

Analysis of Volatile Organics - technical guide (lit. cat.# 59887A)

Brominated Flame Retardants - applications note (lit. cat.# 59389B)

Environmental Gas Standards - Fast Facts (lit. cat.# 59276A)

EZ No-Vent

GC/MS Connector - new product flyer (lit. cat.# 59498)

Foods Flavors & Fragrances In-Review - abstracts of Restek publications (lit. cat.# 59489)

High-Resolution Analyses of FAMEs - applications note (lit. cat.# 59584A)

HPLC minicatalog (lit. cat.# 59241A)

Inlet Supplies - a handy guide to septa, liners, etc. (lit. cat.# 59893B)

Pesticides (PCBs) / GC Racer - applications note (lit. cat.# 59457)

Pinnacle

DB HPLC Columns - new product flyer (lit. cat.# 59499)

Sample Cylinder Technology - product flyer (lit. cat.# 59618A)

STAR Service Rewards - new program: earn credit toward instrument service

(lit. cat.# 59522)

Vu2 Union

Column Connector - new product flyer (lit. cat.# 59505)

For Agilent 5890 & 6890 GCs

(0.25/0.32/0.53mm ID columns)

ID*/OD &

Length (mm)

Similar to

Agilent

cat.#

ea.

cat.#

5-pk.

Drilled Uniliner

®

(hole on top)

4.0 ID

6.3 OD x 78.5

G1544-

80730

21054

21055

Siltek

Drilled Uniliner

®

(hole on top)

4.0 ID

6.3 OD x 78.5

— 21054-214.1 21055-214.5

Drilled Uniliner

®

(hole on bottom)

4.0 ID

6.3 OD x 78.5

G1544-

80730

20756

20771

Double Gooseneck Drilled Uniliner

®

(hole on top)

4.0 ID

6.3 OD x 78.5

G1544-

80700

20508

20509

Double Gooseneck Drilled Uniliner

®

(hole on bottom)

4.0 ID

6.3 OD x 78.5

G1544-

80700

20954

20989

Siltek

1mm Drilled Uniliner

®

(hole on top)

1.0 ID

6.3 OD x 78.5

— 21390-214.1 21391-214.5

For PerkinElmer GCs

(0.32/0.53mm ID columns)

ID*/OD &

Length (mm)

Similar to

PE part#

ea.

cat.#

5-pk.

Auto SYS Drilled Uniliner

®

(hole on top)

4.0 ID

6.2 OD x 92.1

— 20819

20822

Drilled Uniliner

®

Inlet Liners

*Nominal ID at syringe needle expulsion point.