• 15 •
www.restekcorp.com800-356-1688
Restek Solid Phase Extraction Cartridges
For Cleanup of Environmental Samples
Solid phase extraction is one of the most widely used forms of sample preparation. Ease of use, safety, conser-
vative solvent usage, and cost effectiveness all contribute to its popularity.
We offer a range of SPE cartridges to meet demanding cleanup procedures. Our standard products include
Florisil
®
sorbent, ion exchange resins, normal phase materials, and bonded reversed phase materials. In addi-
tion, we offer specialty products, including Florisil
®
in ultraclean glass tubes, mixed bed sorbents, and car-
tridges for specific applications. Our SPE manifolds and pressure/vacuum pump, described in our chromatog-
raphy supplies catalog, will keep your system running efficiently.
Massachusetts TPH Cartridges
• Reduced background extractables.
• Easier quantification.
• Reproducible fractionation patterns, tube after
tube, lot after lot.
• Lower cost than glass tubes.
• Efficient processing on vacuum manifolds.
If you are seeing aromatic hydrocarbons in your
aliphatics fraction, use our Massachusetts TPH silica
gel cartridges. We designed them specifically for sep-
arating aliphatic and aromatic hydrocarbons, to
meet the requirements of the Massachusetts method-
✔
Special purpose SPE cartridges for specific methods.
✔
General purpose cartridges with normal, reversed, or ion exchange phases.
✔
Extraction manifolds and pressure/vacuum pump available.
ology, which has been adopted by other states as
well. Capillary GC columns and reference materials
for the Massachusetts methodology are described in
Application Essentials 59744, available free on
request.
Florisil
®
Cartridges
Florisil
®
adsorbent is an excellent material for
cleanup of samples containing pesticides and/or
PCBs. In addition, it can be used to separate mix-
tures of aliphatic and aromatic hydrocarbons. An
effective cleanup procedure is summarized in
Application Note 59562A, available free on request.
Description
Applications
Tube Volume,
Bed Weight
qty.
cat.# price
Massachusetts TPH
Extraction of hexane-extractable petroleum
hydrocarbons from soil and waste samples.
Specially treated to reduce contaminants and
increase capacity. Silica.
20mL, 5g
20-pk.
26065
EPA Method 548.1
Extraction of endothal from aqueous samples.
Weak anion exchange resin.
6mL
30-pk.
26063
EPA Method 552.1
Extraction of haloacetic acids from aqueous
samples. Strong anion exchange resin.
1mL
100-pk.
26064
Organo Tin
High-capacity cleanup of butyl and phenyl tin
compounds from soil, water, and biota.
Mixed bed.
60mL
16-pk.
24049
RDX
Extraction of explosive compounds (EPA
Method 8330) from water samples.
6mL, 500mg
30-pk.
26093
*Teflon
®
frits
**Glass tubes with Teflon
®
frits
3mL/200mg
3mL/500mg
6mL/500mg
6mL/1000mg
(50-pk.)
(50-pk.)
(30-pk.)
(30-pk.)
Florisil
®
(EPA SW 846 methods and CLP
protocols)
—
24031
—
24034
—
24032*
26086**
26085**
Silica (EPA SW 846 methods)
—
24035
—
24038
—
24036*
—
—
Specialty Cartridges
Specifically designed to provide consistent and reproducible results for the listed method or application.
Polypropylene tubes with polyethylene frits.
Normal Phase Cartridges
Hydrophilic (polar) adsorbents used to extract hydrophilic analytes from nonpolar matrices, such as organic
solvents (e.g., polar contaminants from sample extracts). Polypropylene tubes with polyethylene frits, except as
indicated otherwise.
Resprep
™
12- or 24-Port Tube Manifolds
• Use with any standard male luer-end SPE tube or
cartridge.
• Inert, Teflon
®
sample guides reduce cross-contami-
nation and carryover.
• Flexible sample collection rack will accommodate
a variety of receiving vessels.
• Quick vacuum-release valve for better control.
• Individual vacuum control for each tube—
improves reproducibility.
Complete manifold
includes glass basin with
built-in vacuum regulator,
polypropylene top plate
with 12 or 24 individual
control valves, 12- or 24-
position collection rack,
and 12 or 24 Teflon
®
sample guides.
Description
qty.
cat.# price
Resprep
™
12-Port Manifold
kit
26077
Resprep
™
24-Port Manifold
kit
26080
Massachusetts EPH/VPH/APH Methods
(lit. cat.# 59744)
Massachusetts’ gas chromatographic methods for
volatile (VPH), extractable (EPH), and air phase (APH)
fractions of gasoline and other petroleum products
have been adopted by other states, and in Canada. This
4-page publication lists many Restek products that can
help a laboratory meet the requirements of the
Massachusetts methods, including capillary columns
(Restek columns are specified in each method), extrac-
tion cartridges, analytical reference materials, and air
sampling canisters.
Free
!
Call our literature hotline: 800-356-1688
or 814-353-1300, ext. 5, or contact
your Restek representative.
by Lydia Nolan, Instrument Support Chemist