The rugged Silcosteel
®
tubing will hold up indefi-
nitely to temperatures in excess of 430°C, so col-
umn lifetime is not limited by the tubing. To
demonstrate the utility of this innovative product,
we analyzed Polywax
®
1000 using the MXT
®
-1HT
Sim Dist column (Figure 2). Notice the excellent
peak shape of hydrocarbons up to C110.
To maintain the low bleed and high performance of
the MXT
®
-1HT Sim Dist column, it is critical to pre-
vent oxygen from entering the column. This can be
achieved by electronically leak checking your entire
system. We also recommend the use of graphite fer-
rules; Vespel
®
or Vespel
®
/graphite ferrules are
more likely to loosen over time.
The MXT
®
-1HT Sim Dist column is available in a
5m, 0.53mm ID, 0.1µm film to conform to the
requirements of ASTM Method D-6352. It exceeds
the criteria for resolution, peak shape, and bleed
for hydrocarbons ranging up to C110.
columns are manufactured using polyimide-coated
fused silica tubing. At temperatures above 380°C,
even the best polyimide coating becomes brittle,
which leads to very short column lifetimes. In addi-
tion, the methyl silicone stationary phase recom-
mended in the method also must survive these high
temperatures.
Extensive research by scientists at Restek has led to
a major improvement in columns for high-tempera-
ture simulated distillation. By combining a new
proprietary polymer synthesis technology, Siltek
™
deactivation chemistry, and rugged Silcosteel
®
tub-
ing, we developed a capillary column that meets all
the criteria of ASTM Method D-6352. Because the
MXT
®
-1HT Sim Dist column is coated with a 100%
dimethyl polysiloxane polymer, it will give the cor-
rect retention time/boiling point curve. The MXT
®
-
1HT Sim Dist column exhibits low bleed at 430°C
and excellent peak shape due to the unique poly-
mer synthesis and Siltek
™
deactivation (Figure 1).
MXT
®
-1HT SimDist
(metal column)
Length (m)
ID (mm)
df(µm)
Temp. Limits
cat.#
5
0.53
0.10
-60 to 430°C
Please note:
For high-temperature analyses such as simulated distillation,
Restek strongly recommends the use of the following accessories to ensure low
bleed and maintain high performance.
Capillary Graphite Ferrules
For
1
/
16
" compression-type fittings
Ferrule ID (mm)
Fits Column ID (mm)
10-pack
50-pack
0.8
0.53
For Agilent GCs (compact ferrules)
Ferrule ID (mm)
Fits Column ID (mm)
10-pack
50-pack
0.8
0.53
For M4 fittings for QCQ ThermoQuest 8000 & Trace GCs
Ferrule ID (mm)
Fits Column ID (mm)
2-pack
10-pack
0.8
0.53
Standard Graphite Ferrules
For
1
/
4
" fittings
Fitting Size (")
Ferrule ID (")
10-pack
1
/
4
1
/
4
D6352-98 Polywax
®
Standards
These high molecular weight hydrocarbon
waxes are useful for simulated distillation
and other high-temperature GC work.
Ea.
cat.#
qty.
Polywax 500
36224
1 gram
Polywax 655
36225
1 gram
Polywax 850
36226
1 gram
Polywax 1000
36227
1 gram
Triple Filter: Removes xygen/moisture and hydrocarbon impurities. cat.# 22020, (ea.) $130
Single-Position Baseplate:
Ultra-High Capacity Oxygen Filter:
Leak Detective
™
Electronic Leak Detector
• Compact, lightweight, hand-held design.
• Lowest-cost thermal conductivity leak detector available.
• Contamination-free leak detection.
• Detects helium or hydrogen trace leaks at 3 x 10
-4
cc/sec. or 200ppm.
• Audible alarm and LED readout.
• Responds in less than 2 seconds to trace leaks of gases.*
• Operates on two 9-volt batteries or AC adaptor, both included.
*Not designed for use in explosive atmospheres.
Many GC problems can be avoided by
electronic leak checking the system dur-
ing the plumbing process. Thorough leak
checking will prevent loss of GC gases,
damage to capillary columns, and
increased detector maintenance. Oxygen
can move into the system via a leak due
to the Venturi effect, and irreversible
damage can occur if a column is exposed
to oxygen at high temperatures, such as
those needed for simulated distillation.
Also, some detectors are very sensitive to
oxygen. Leak checking the instrument
before column installation and condition-
ing prevents column degradations indicat-
ed by high bleed and short lifetimes. Leak
checking should be performed on the
entire gas system and GC. Begin by
checking all fittings inside the GC. Next
check the external fittings along the carri-
er gas lines, all the way to the tanks.
Never use liquid leak detectors that con-
tain soap or surfactants because liquids
can be drawn inside the fitting at the site
of the leak and contaminate the system.
Hot Tech Tip
Super-Clean
™
SGT Gas Filters
• High-purity output (99.9999% purity).
• Features a “quick connect” for fast and simple cartridge
changes.
• Full glass/metal design with easy-to-read indicators.
70100
20224
20202
20252
20284
20285
20253
20210
European 2-prong plug (220 VAC):
cat.# 21382 (ea.)
(110 VAC):
cat.# 21607, (ea.)
cat.# 22029, (ea.)
cat.# 22025, (ea.)
(220 VAC):
cat.# 21609, (ea.)