GC COLUMNS |

METAL MXT® CAPILLARY COLUMNS

General-Purpose Columns

Intermediate-Polarity Deactivated MXT® Guard/Retention Gap Columns/

Transfer Lines

(passivated stainless steel)

• Useful for a wide range of applications.

• Compatible with most common solvents.

• Maximum temperature: 325 °C.

Hydroguard®-Treated MXT® Guard/Retention Gap Columns/Transfer Lines

(passivated stainless steel)

• Extend analytical column lifetime by preventing degradation from harsh

“steam-cleaning” water injections.

• Maximum temperature: 325 °C.

When transfer lines from purge-and-trap systems, air monitoring equipment, or other

instruments carry condensed water vapor, deactivated column tubing quickly becomes

active because of the creation of free silanol groups. These silanol groups adsorb active

oxygenated compounds, such as alcohols and diols.

Restek chemists have addressed this concern and found a solution—Hydroguard® de-

activated tubing. A unique deactivation chemistry creates a high-density surface that

is not readily attacked by aggressive hydrolysis. The high-density surface coverage of

the Hydroguard® deactivation layer effectively prevents water vapor from reaching the

surface beneath. Use Hydroguard® tubing for connecting GCs to:

• Headspace analyzers.

• Air analysis equipment and concentrator units.

• Purge-and-trap systems.

*30-meter lengths are banded in 5-meter sections.

Diameters greater than 0.10 mm are tested with the Grob test mix to ensure high inertness.

5-Meter

5-Meter (6-pk.)

10-Meter

Nominal ID

Nominal OD

cat.#

price

cat.#

price

cat.#

price

0.28 mm 0.56 ± 0.025 mm 70044

70044-600

70046

0.53 mm 0.74 ± 0.025 mm 70045

70045-600

70047

5-Meter

10-Meter

30-Meter*

Nominal ID

Nominal OD

cat.#

price

cat.#

price

cat.#

price

0.28 mm 0.56 ± 0.025 mm 70080

70083

70086

0.53 mm 0.74 ± 0.025 mm 70081

70084

70087

Connect transfer lines or guard columns directly to your

MXT® columns without compromising your data.

Rugged MXT® low dead volume connectors are Siltek® treated to make them inert to

active compounds, just like our MXT® columns! They can be used at temperatures up to

430 °C without degrading the deactivated layer, and their low thermal mass tracks rapid

oven temperature programming. Kits are available for 0.28 mm, 0.32 mm, and 0.53 mm

ID columns in a standard configuration for column-to-column connections and a “Y”

configuration for connecting two columns to one inlet or one column to two detectors.

In addition to the MXT® union, each kit also contains stainless steel

1

32

-inch ferrules

and nuts. (See

page 232

for more details.)

MXT® guard

column

MXT® low dead volume connector

MXT® analytical

column

Connect MXT® columns using an

MXT® low dead volume connector!

also available

Column connector

kits & ferrules

See

page 232

.

Certificates of analysis for 5 m and 10 m

Restek® guard columns are provided

electronically. To view and download your 5 m

or 10 m guard column certificate, simply visit

www.restek.com/documentation

then enter

your catalog # and serial #.

did you know?