MRC-2013-Catalog - page 422

422
M
MPA-1, Melting Point Apparatus
MPA-3, MPA-12 Melting Point Apparatus
MPA-1
MPA-12
Characteristics:
Automatic photoelectric detection can well complete all
detection tasks under no attention.
It’s mainly used for the detection of melting points of
medicines, spices, dyes and other organic crystal
substances.
Large-size LCD screen can directly display as many as
three melting curves at the same time
Characteristics:
Advanced true-color VGA touch screen is easy for
operation and observation.
8-level linear temperature rise design is satisfactory
for varied temperature rise options.
Wider temperature control scope and higher
temperature accuracy.
Optimal cooling rate and sample test speed.
Exclusive integral design.
It’s completely in line with pharmacopeia and GLP
requirements. (MPA-3 only)
Three independent temperature detection systems
ensure the detection of three samples of varied
melting points. (MPA-3 only)
The variation curve of tested sample can be
displayed in a timely manner. (MPA-3 only)
RS232 interface, associated computer software
and external computer control are available.
Detailed test data can be stored. (MPA-3 only)
MPA-1 Digital Melting Point Apparatus is integrated
with photoelectric detection, digital temperature
display and other technologies, boasts automatic
display of initial and final melts and other functions. In
the temperature system, linearly calibrated platinum
resistor is used as the detection device, offer efficient
and accurate test process and results.
The apparatus can be widely used in the chemical
industry and medicine research and is essential for
the production of medicines, spices, dyes and
measurement of other organic crystal substances.
MPA-12/3 Digital Melting Point Apparatus are integrated
with photoelectric detection, digital temperature display
and other technologies, boasts automatic display of initial
and final melts and other functions. In the temperature
system, linearly calibrated platinum resistor is used as the
detection device, offering efficient and accurate test
process and results. The apparatus can be widely used in
the chemical industry and medicine research and is
essential for the production of medicines, spices, dyes and
measurement of other organic crystal substances.
Model
MPA-1
Melting point range
Room temperature - 320°C
“Initial temp.” setting
6min. from room temp. to 320°C
7min. from 320°C to room temp.
Min. displayed temp.
0.1°C
Temp. accuracy
±0.4°C (<200°C), ±0.7°C (<300°C)
Linear temperature rise
0.2°C/min, 0.5°C/min,
1°C/min, 1.5°C/min, 2°C/min,
3°C/min, 4°C/min or 5°C/min
Standard capillary size
Inside dia. 1.0mm, outside dia.
1.4mm
Power supply
220V 50Hz
Power
100W
Model
MPA-3
MPA-12
Melting point range
Room temperature - 400°C
“Initial temp.” setting
7min. from room temp. to 400°C
7.5min. from 400°C to room temp.
Min. displayed temp.
0.1°C
Temp. accuracy
±0.4°C (<200°C), ±0.7°C (<300°C)
Linear temperature rise
0.1°C/min, 0.2°C/min,
0.5°C/min, 1°C/min, 2°C/min,
3°C/min, 4°C/min or 5°C/min
Standard capillary size
Inside dia. 1.0mm,
outside dia. 1.4mm
Power supply
220V 50Hz
Power
100W
MELTING POINT