Falcon CALIDUS microGC -012 - page 13

CALIDUS
tm
101HTmicroGasChromatograph
SimulatedDistillationGCanalysis for virtuallyanyhydrocarbon fuel or fuel blend
component up toC
50
for laboratory, at-line, transportableor onlineuse.
CALIDUSModel 101HT -
comprisedof 3modules fittedwithhigh temperature inlet and columnoperational
components
A singleSampleProcessingUnitwitha standard split/splitless injectionport (1:1up to1:200) suitable for gasand
liquid samples viaeither syringe through the septum injections, optional gas, liquidor headspaceauto-sampler, or
automated samplingvalves. The inlet includes septumpurge toprevent bleed components fromentering the
system. Themaximumoperating temperature is350
o
C.
A singleProgrammedTemperatureColumnModule containingahigh temperature resistivelyheated steel capillary
chromatography columnwithnecessaryhardware, softwareandelectronic control toenable temperature
programming from0.1
o
C to5
o
Cper second from5
o
Caboveambient to400
o
C. The column isMxt 1-HT forhigh
temperature simulateddistillationgas chromatography.
A singleDetectorModule incorporatingamicro Flame IonizationDetector (FID)with thenecessaryhardware,
softwareandelectronic control toprovidedetector temperature control (350
o
Cmaximum), digital output signal and
additionally for proper FID fuel supplypressureandauto-ignition.
ThemicroFID is a fullydigital carbon/hydrogenbonddetectorusing thehydrogen flame toburn the sample
components. It uses anelectrometer to sense the current changes in the flame cell due to chromatographic
component elution. Thedata rate is100Hz.
CALIDUS101-HT is controlledwithChromPerfect chromatographydata system fully integratedwith LineUpand
SimDist 2000 runningonaWindowsPC. AnASTMmethod forUltraFastMicroGCD-2887 is currentlyunder
development basedonCALIDUS101-HT.
100AEI Drive
Fairlea,WV24901
P.O. Box518
Ronceverte,WV 24971
Phone: 304-647-5860
Fax: 304-645-4006
E-mail:
SIGNIFICANCEANDUSE
TheModel 101HTprovides a simpleultra-fast (10 to50 times faster than conventional labor
processGC’s) simulateddistillationanalysis for hydrocarbons toC
50
. This system is ideally
configured for liquid fuels and fuel component characterizationbyboiling rangedistribution
includinggasoline rangeorganics up throughgasoil andeven crudeoil.
Theanalyses areused for exploration&production liquids characterization, fuels specification
testing, regulatoryevaluations, environmentalmeasurements, process control, transportable
spot checkof fuels andmanymore.
Faster, Smaller, Smarter, Easier,Greener
Upstream (E&P)
Refining
Petrochemical/Chemical
Military
Educational