POWER STATUS VACUUM
EXHAUST
VALIDATION
POWER
15-24V
DC
0.85AMAX.
5.17"
[131mm]
2.87"
[73mm]
10.35"
[263mm]
POWER STATUS VACUUM
3.12"
[79mm]
6.42"
[163mm]
11.67"
[296mm]
EXHAUST
VALIDATION
POWER
15-24V
DC
0.85AMAX.
PartNo.
NumberofChannels
Channel Volume
MaxHPLCGradient
FlowCapability
PressureDrop
E
DegassingFlowPath ID
SYSTECSTANDALONEMINI VACUUMDEGASSINGSYSTEMS—AVAILABLECONFIGURATIONS
A
0001-6500
2
480µL
2.0mL/min
C
0.18kPa/mL/min
0.045” (1.14mm)
0001-6501
4
480µL
2.0mL/min
C
0.18kPa/mL/min
0.045” (1.14mm)
SYSTECSTANDALONEPREPSCALEVACUUMDEGASSINGSYSTEMS—AVAILABLECONFIGURATIONS
A, B
0001-6482
2
8.4mL
20mL/min
D
0.04kPa/mL/min
0.065” (1.65mm)
0001-6484
2
13.8mL
40mL/min
D
0.06kPa/mL/min
0.065” (1.65mm)
A.Customconfigurationsareavailable.Consult us for yourownOEM solution toyour specificapplication.
B. The standardprep scalechambersarenot recommended forGPCapplicationsor for usewithHFIP (hexafluoroisopropanol).
C. Theflow ratesgivenare for agradientmixtureof 50/50MeOH/H
2
O,witha typical lowpressuregradientmixingvalve.Higher flow ratesarepossiblewithhighpressuremixing.
D. Theflow ratesgivenare for agradientmixtureof 60/40MeOH/H
2
O,witha typical lowpressuregradientmixingvalve.Higher flow ratesarepossiblewithhighpressuremixing.
E. Estimated tubingpressureper unit change inflowassuming laminar flowwithaviscosityof 1.0cP
NOTE
Power Requirement
Input Power requiredwithACAdapter (included):
100 to240VAC
(±10%), 1A, 50 to60Hz (±3Hz). Four interchangeablewall socketsare
suppliedwith theACAdapter:NorthAmerica/Japan,U.K.,Continental
Europe,Australia.
CECertification
Thisproduct hasbeencertifiedunder the followingCE testing standards:
EN61326-1; EN55011; EN61300-3-2; EN61300-3-3,&EN61010-1.
Systec
®
StandAloneMINI&PrepScale
VacuumDegassingSystems
XX
Analytical andPrep scalemodels
XX
Ultra-highdegassingefficiency
XX
Low volume, easy toprime
XX
Patented control eliminates baseline fluctuations
XX
Inert flowpath
XX
5+ year lifetime
TheSystecStand-AloneMINIandPrep-ScaleHPLCvacuumdegassing
systems are high-efficiency, in-linemodules that removedissolved
gases from themobilephase. Their uniquedesign assures reliable
continuousoperationand thehighest level of performanceavailable
without theneed forhelium sparging.Up tofive solvent linesmaybe
degassed simultaneouslybyoneunit.
ZHCR
®
ControlwithBuilt-inTestDiagnostics
XX
Microcontroller self-test vacuum sensor validationonpower-up
XX
Continuous vacuum systemmonitoring toensureoptimum
operational conditions aremaintained
XX
Vacuum system fault detection and shutdown function indicators
AF / ZHCRDegassingTechnology
Flow-through vacuumdegassing chamber with a single amorphous
perfluorinated copolymer (Systec AF
®
) degassing membrane,
enablingdegassingefficiency50 times that of PTFE.
TheZHCR (ZeroHysteresis /ConstantRun) vacuumpumpemploysa
patentedclosed-loop,micro-steppingrpmcontrolstrategypermitting
thepump to runwith continuously variable speed, providingquick
pull-downathigh rpm, and thensustainingaconsistent vacuum level
at low rpm.
Fluctuations indetectorbaselinedue tochanges invacuum level are
eliminatedbynot having to repeatedly stopand start a single-speed
pump. This alsogreatly reduceswear andnoise.
Thebrushlessmotor enables quiet operation and is appropriate for
environmentswhere solvent vaporsmaybepresent.
Overall Dimensions
SPECIFICATIONS
Stand-AloneDegassingModules
MaximumNumber ofDegassingChannels
5
DegassingEfficiency
@1mL /minMeOH
>70%O
2
Removal
MembraneMaterial
SYSTECAF
OtherWettedMaterials
PEEK, PPS(GF), PTFE(GF), FEP
SolventCompatibility
Not compatiblewithfluorinated solvents.
Special versionavailable forGPC solvents.
FlowPath ID
1.14mm (0.045”)
Internal Volume
480µL (standard)
MaximumPressure (@25 °C)
0.5MPa (70psi)
PressureDrop
0.18kPa/mL/min
†Degassingefficiencycanbeoptimizedbasedonflow rate, fluid tobedegassed, andgas tobe removed.