restektn07 - page 325

acenaphthene-d10
chrysene-d12
1,4-dichlorobenzene-d4
naphthalene-d8
perylene-d12
phenanthrene-d10
SV InternalStandardMix
2,000µg/mL each inmethylene chloride, 1mL/ampul
cat.# 31206 (ea.)
$39
4,000µg/mL each inmethylene chloride, 1mL/ampul
cat.# 31006 (ea.)
$76
2-fluorobiphenyl
nitrobenzene-d5
p
-terphenyl-d14
B/NSurrogateMix (4/89SOW)
1,000µg/mL each inmethylene chloride, 1mL/ampul
cat.# 31024 (ea.)
$27
5,000µg/mL each inmethylene chloride, 1mL/ampul
cat.# 31062 (ea.)
$41
5,000µg/mL each inmethylene chloride, 5mL/ampul
cat.# 31086 (ea.)
$110
5,000µg/mL each inmethylene chloride, 10mL/ampul
cat.# 33028 (ea.)
$210
2-fluorophenol
phenol-d6
2,4,6-tribromophenol
AcidSurrogateMix (4/89SOW)
2,000µg/mL each inmethanol, 1mL/ampul
cat.# 31025 (ea.)
$27
10,000µg/mL each inmethanol, 1mL/ampul
cat.# 31063 (ea.)
$41
10,000µg/mL each inmethanol, 5mL/ampul
cat.# 31087 (ea.)
$110
10,000µg/mL each inmethylene chloride, 10mL/ampul
cat.# 33029 (ea.)
$210
benzidine
4,4'-DDT
DFTPP
pentachlorophenol
GC/MSTuningMixture
1,000µg/mL each inmethylene chloride, 1mL/ampul
cat.# 31615 (ea.)
$28
8270MatrixSpikeMix
(76 components)
200µg/mL each inmethanol:methylene chloride (80:20), 5mL/ampul
cat.# 31687 (ea.)
$157
benzidine
3,3'-dichlorobenzidine
605BenzidinesCalibrationMix
2,000µg/mL each inmethanol, 1mL/ampul
cat.# 31030 (ea.)
$28
2,000µg/mL each inmethylene chloride, 1mL/ampul
cat.# 31834 (ea.)
$28
TheDrilledUniliner
®
is themost inert linerbecause themetal injectionport outside theglass
liner does not contact the sample path– the sample is virtually “funneled” into the column.
Also, when using the Drilled Uniliner
®
inlet seals do not need to be replaced – a savings in
maintenance cost and time. The cyclo double gooseneck liner is recommended with pres-
sure pulse conditions. Its corkscrew type sample path enhances sample vaporization and
helps prevent sample contactwithmetal surfaces below the liner. When using a gooseneck
type liner, however, routinely replacing the inlet seal below the liner is critical. Gold plated
andSiltek
®
treated linersandsealsbothensurean inert samplepath, however, Siltek
®
treat-
ed surfaces aremore resistant to abrasion during cleaning.
Injection port liners are designed inmany configurations, four of which are commonly used
for semivolatilesanalysis: thesinglegooseneck, doublegooseneck, cyclodoublegooseneck,
and the Drilled Uniliner
®
.While all four liner types are used for 8270 analysis, we recom-
mend the Drilled Uniliner
®
when using constant flow, and the cyclo double gooseneck with
pressure pulse conditions.
DrilledUniliner
®
(hole on bottom)
0.8mm IDDual Vespel
®
Ring Inlet Seal
Gooseneck Splitless (4mm)
CycloDoubleGooseneck (4mm)
DoubleGooseneck Splitless (4mm)
4.0 ID 6.5OD x 78.5 20799 5 pk.
$85
4.0 ID 6.5OD x 78.5
20896 5 pk.
$293
4.0 ID 6.3OD x 78.5 20771 5 pk.
$284
Siltek
®
Treated
21242 2-pk.
$58
Stainless Steel
21238 2-pk.
$45
Gold Plated
21240 2-pk.
$58
4.0 ID 6.5OD x 78.5 20785 5 pk.
$101
8270MegaMix®
(76 components)
1,000µg/mL each inmethylene chloride, 1mL/ampul,
cat.# 31850 (ea.)
$112
InertSamplePath IncreasesAccuracy
Analytes
contact hot
surface and
dead volume
at base of
splitless liner
Drilled
Uniliner
®
inlet
liner efficiently
transfers sample
onto column
Use hole near top configuration for
chlorinated pesticide analysis, when
analytes elute away from the solvent
peak, or when the sample solvent iswater
Use hole near bottom configuration for
semivolotile analysis or when analytes
elute near the solvent peak
restek
innovation
!
TheDrilledUniliner
®
TheDrilledUniliner
®
provides themost inert sample pathway of all inlet liners for splitless
injection techniques.This liner connects directly to the column, eliminating contact between
the active compounds and activemetal surfaces in the injector, and ensuring an inert
sample pathway for analyte transfer from the injection port to the column.
Refer to figure for compound list
Liners shown are for Agilent instruments; liners for other instrument brands also are
available. For a complete list of liners and seals refer to our catalog or website.
AnalyticalReferenceMaterials
5
1...,315,316,317,318,319,320,321,322,323,324 326,327,328,329,330,331,332,333,334,335,...344
Powered by FlippingBook