Table of Contents Table of Contents
Previous Page  409 / 413 Next Page
Information
Show Menu
Previous Page 409 / 413 Next Page
Page Background

GC Accessories

Peak Performers

Injection Port Maintenancewith FastPack™Inlet Kits

by Donna Lidgett, GCAccessories Product Manager

What are the benefits of using a FastPack™Inle t Kit?

Fastl'ack" inlet kits include all the parts needed to maintain your system. Injection port main­

tenance should be performed prior to installing any capillary column, and on a routine basis,

based on the number of injection s made and the cleanliness of the samples. Maintenance

includes replacing the injection port (inlet) liner, the critical inlet seals, and the septum.

Why replace an injection port liner?

For optimum column performance, the injection port (inlet) liner must be free of septum par­

ticles, sample residue, or ferru le fragment s. Peak shape degradation , poor reproducibilit y,sam­

ple decomposition, and ghost peaks all are associated with using a dirt y (contaminated) liner.

Why replace the critical seal?

The critical seal mu st fit tightly around the inlet liner, to prevent carrier gas from leaking

around the out side of the liner. Replace the critical seal prior to installing an inlet liner.

Why replace the septum?

The septum maintains a leak-tight seal that excludes air from the inlet. Frequent replacement prevents

fragment ation and leaks. Multiple injections and continuous exposure to hot injection port surfaces will

decompose the septum and can create particles, which can fall into the inlet liner. Septum particles are a

potential source of ghost peaks, loss of inertness, and carrier gas flow occlusion. Allow a new septum suf­

ficient time to condition in the injector, to reduce the inciden ce of ghost peaks. To avoid contamination,

always use forceps when handling septa.

Why replace the inlet seal?

great way to make routine

In Agilent split/splitless injection ports, the inlet seal sits at the base of the injector. Dirt, non -volatile

maintenanceeasy. Each kit

residue, septum fragments, and other undesirable materials contaminate the inlet seal and decrease anaincludes one each: inlet liner

(choosefromfour popular

Iyticallinearity. The only way to maintain optimum performance is by frequently changing the inlet seal

styles), Viton

e

a-ring, O.8mm

and ensuri ng the seal is leak-tight.

10gold-plated inletseal, inlet

FastPack™Inlet Kits for Agilent GCs

seal washer, llmm

Thermolite"

septum.

• Convenient: all the parts you need in one package-no hun ting for individual items.

• Economical: costs less than the sum of the individual parts.

• Clean: Mylar®bag is factory sealed; no cont amination of the prod ucts from weeks in the lab.

1 pack includes5 maintenance kits

1 pack

5-19

20or more

Deactivated Liner

cat.#

(5 kits)

packs

packs

4mm Splitless

21101

$193/ pk.

$183/pk.

$173/pk.

4mmSplitlessGooseneck

21102

$213/ pk.

$203/pk.

$193/ pk.

4mm Splitless Double Gooseneck

21103

$253/ pk.

$241/ pk.

$228/pk.

4mm Split withWool*

21104

$203/ pk.

$193/pk.

$183/pk.

* Liner dimensionsare 4mm10, 6.3mm 00, 78.5mm long. Liners in other kits are 6.5mm00.

Liners for Agilent/Finnigan GCs

Benefits/Uses

10*/00

&

l ength (mm)

Similarto AgHent

part #

ea.

cat.#/price

5-pk.

25-pk.

2mm Splitless

trace samples < 2j.1L

2.0 ID

6.5 00 x 78.5

5181-8818 (ea.)

5183-4703 (5-pk.)

5183-4704 (25-pk.)

20712

$23

20713

$77

20714

$233

4mm Splitless

trace samples > 2j.1L

4.0ID

6.500 x 78.5

210-3003 (ea.)

210-3003-5 (5-pk.)

20772

$19

20773

$58

20774

$233

Siltek" 4mm Splitless

trace samples > 2j.1L

4.0ID

6.5 00 x 78.5

20772·214.1

$24

20773-214.5

$78

20774-214.25

$322

Gooseneck Splitless(4mm) w/ Woolt

trace samples > 2J.1l

4.0ID

6.500 x 78.5

5062·3587 (ea.)

5183-4693 (5-pk.)

5183-4694 (25-pk.)

22405

$29

22406

$81

22407

$329

4mm Splitw/ Wool

universal, usewith

Agilent 7673

autosampler

4.0ID

6.3 00 x 78.5

19251-60540 (ea.)

5183-4691 (5·pk.)

5183-4692(25-pk.)

20781

$23

20782

$67

20783

$274

SHtek" 4mm Split w/ Wool

universal, use with

Ag ilent 7673

autosampler

4.010

6.3 00 x 78.5

20781-213.1

$42

20782-213.5

$116

20783-213.25

$442

FastPack'· Inlet Kitsare a

2006.03

800-356-1688 •

www.restek.com

• 28 •

Website :

www.chromtech.net.au

E-mail :

info@chromatech.net.au

TelNo : 03 9762 2034 . . . in AUSTRALIA