MXT®-Biodiesel TG Columns (Siltek® treated stainless steel)

**Connected with low-dead-volume Alumaseal™ connector.

Description

temp. limits

cat.#

price

14m, 0.53mm ID, 0.16 w/2m Integra-Gap™

-60 to 380/430°C 70289

10m, 0.32mm ID, 0.10

-60 to 380/430°C 70292

10m, 0.32mm ID, 0.10 w/2m x 0.53mm retention gap** -60 to 380/430°C 70290

15m, 0.32mm ID, 0.10

-60 to 380/430°C 70293

15m, 0.32mm ID, 0.10 w/2m x 0.53mm retention gap** -60 to 380/430°C 70291

Rtx®-Biodiesel TG Columns (fused silica)

**Connected with low-dead-volume Alumaseal™ connector.

Description

temp. limits

cat.#

price

10m, 0.32mm ID, 0.10

to 330/380°C 10292

10m, 0.32mm ID, 0.10 w/2m x 0.53mm retention gap** to 330/380°C 10291

15m, 0.32mm ID, 0.10

to 330/380°C 10294

15m, 0.32mm ID, 0.10 w/2m x 0.53mm retention gap** to 330/380°C 10293

10 x 0.32mm ID and 15m x 0.32mm ID, both of

which are factory coupled to a 2m x 0.53mm

retention gap using an Alumaseal™ connector.

Excellent resolution of all glycerides is achieved, as

shown in Figure 2.

Restek has also developed an innovative column

where the analytical column includes a built-in

retention gap in a continuous section of tubing,

requiring no connectors. This column, the MXT®-

Biodiesel TG column, is 14m x 0.53mm ID, and

features a 2m x 0.53mm ID Integra-Gap™ inte-

grated retention gap (Figure 3). This product elim-

inates any need for connections because the column

and retention gap are one piece of continuous tub-

ing. Target analytes resolve exceptionally well and

the solvent and triglyceride peaks show excellent

symmetry (Figure 4). Peak shape for butanetriol is

very good, demonstrating inertness, and the resolu-

tion and response of the glycerides is also excellent.

Conclusion

There are several column options available for

analyzing total glycerin in biodiesel fuels. The best

chromatographic solution for this analysis is the

14m x 0.53mm ID MXT®-Biodiesel TG column

with the 2m x 0.53mm ID Integra-Gap™ integrated

retention gap. This column eliminates the column

connection and can be used to 430°C allowing for

faster analysis times and higher sample throughput.

Figure 3

The Ultimate Biodiesel Solution:

MXT®-Biodiesel TG column with Integra-

Gap™ integrated retention gap.

The 0.53mm MXT

®

-Biodiesel TG columns are an innovative

alternative to using a 0.32mm column coupled to a 0.53mm

retention gap. Restek applied the Integra-Gap

integrated

retention gap technology to the 0.53mm MXT

®

-Biodiesel TG

columns, eliminating the column coupling. These 100%

leak-proof columns feature a built-in retention gap, reduc-

ing the risk of peak broadening and tailing, and guarantee-

ing the user many analyses without downtime.

Figure 4

Excellent chromatographic quality and resolution on the

0.53mm MXT®-Biodiesel TG column, with the Integra-Gap™ inte-

grated retention gap.

0

10

20

Time (min)

Column:

MXT

®

-Biodiesel TG, 14m, 0.53mm ID, 0.16µm (cat.# 70289) with

a 2m x 0.53mm Integra-Gap™ retention gap

(16m total length)

Sample:

biodiesel (B100), derivatized

Inj.:

cool on-column injection

1µL in heptane

Inj. temp.:

oven track

Carrier gas:

hydrogen, constant flow

Flow rate:

4mL/min.

Oven temp.:

50°C (hold 1 min.) to 180°C @ 15°C/min. to 230°C @ 7°C/min. to

380°C @ 30°C/min. (hold 5 min.)

Det.:

FID @ 380°C

GC_PC00969

Glycerin

Monoglycerides

Monoglycerides

Diglycerides

Triglycerides

butanetriol (IS)

tricaprin (IS)

The best solution

for analyzing

total glycerin in

biodiesel!