Table of Contents Table of Contents
Previous Page  189 / 413 Next Page
Information
Show Menu
Previous Page 189 / 413 Next Page
Page Background

• 15 •

2008 vol. 2

The Cliquid® Drug Screen & Quant Software automates this test and generates

a verification report which highlights failures. Peak area, peak shape, retention

time reproducibility, fragmentation, and library search function all are evalu-

ated through the software by comparing the test mix data to expected results.

For example, full scan linear ion trap MS/MS data for diazepam and caffeine

are compared to the library to assess fragmentation. A mass spectral match of

80% or more must be achieved to pass this portion of the system suitability

test. Otherwise, the failure will be highlighted on the automated report.

Analyzing this system suitability mix for drug analysis on a regular basis

assures system performance, improves data quality, increases sample through-

put, and simplifies troubleshooting. Moreover, the Cliquid® Drug Screen &

Quant Software for Routine Forensic Toxicology enables nonexpert

LC/MS/MS users to employ this system suitability test with little effort.

Acknowledgement

Method and data supplied by Applied Biosystems.

References

H. El Arbi, T. Sasaki, A. Schreiber, K. Sellers, K. Herwehe. Development of an LC/MS/MS System Suitability Test

for Forensic Toxicology Applications. Applied Biosystems/MDS Sciex, 2007.

amiodarone

10µg/mL

amphetamine

10

caffeine

10

codeine

10

diazepam

10

doxepine

10

haloperidol

1

morphine

10

Forensic Drug Screen Test Mixture

In P&T methanol, 1mL/ampul

cat. # 36340

(ea.)

D5-diazepam

D5-doxepine

Forensic Drug Screen Internal Standard

10µg/mL each in P&T methanol, 10mL/ampul

cat. # 36341

(ea.)

Allure® PFP Propyl Columns (USP L43)

Excellent Columns for LC/MS and ELSD

Physical Characteristics:

5µm Column, 2.1mm

cat. #

price

30mm

9169532

50mm

9169552

5µm Column, 3.2mm

cat. #

price

30mm

9169533

50mm

9169553

5µm Column, 2.1mm

cat. #

price

30mm (with Trident Inlet Fitting)

9169532-700

50mm (with Trident Inlet Fitting)

9169552-700

5µm Column, 3.2mm

cat. #

price

30mm (with Trident Inlet Fitting)

9169533-700

50mm (with Trident Inlet Fitting)

9169553-700

particle size: 5µm, spherical

pore size: 60Å

carbon load: 17%

endcap: fully endcapped

pH range: 2.5 to 7.5

temperature limit: 80°C

ABI/SCIEX Cliquid® Drug Screen Mix

Trident Direct Guard Cartridge System

Easy to Use, Low Dead Volume—The Ultimate

Combination of Convenience and Column

Protection

Description

qty. cat.#

price

10mm guard cartridge holder with filter

ea. 25084

20mm guard cartridge holder with filter

ea. 25086

Connection tip for Waters-style end fittings ea. 25088

PEEK tip standard fittings

ea. 25087

Trident Direct 10mm

guard cartridge holder

with filter

Protection against

particulate matter and

moderate protection

against irreversibly

adsorbed compounds.

Trident Direct 20mm

guard cartridge holder

with filter

Protection against

particulate matter and

maximum protection

against irreversibly

adsorbed compounds.

Allure

®

PFP Propyl Guard Cartridges qty.

cat. #

price

10 x 2.1mm

3-pk.

916950212

10 x 4.0mm

3-pk.

916950210

20 x 2.1mm

2-pk.

916950222

20 x 4.0mm

2-pk.

916950220

ordering

note

For other dimensions of these columns, visit our website at

www.restek.com

.

Use this system suitability mix for drug

analyses to assure system performance

and simplify troubleshooting.

Get More!

Clinical/Forensics/Toxicology

Related Articles Online

“Fast Screening and

Confirmation for Gamma-

Hydroxybutyrate (GHB)”

www.restek.com/CFT