bioaccumulation (e.g., PCB#169). The list encom-

passes the seven European indicator compounds

and the 12 most toxic congeners, according to the

World Health Organization (WHO) list.²

Using a 40m x 0.18mm ID, 0.18µm film Rtx®-PCB

column and the conditions listed in Figure 2, we

evaluated a sample composed of Aroclor® PCB

mixes 1242, 1254, and 1262. The 158 target PCB

congeners were identified in the sample, eluted as

135 chromatographic peaks. Of the 158 congeners,

110 eluted singly and 48 were unresolved.

Produced through one of our newest polymer

technologies, Rtx®-PCB columns undergo rigor-

ous quality assurance measures, to ensure every

column meets exacting standards and to give you

highly reproducible performance, from column to

column. If you are analyzing PCBs—as congeners,

as Aroclor® mixtures, or as other mixtures (e.g.,

Kaneclor, Clophen, or Phenoclor mixes)—we

highly recommend using these new columns.

Table I

110 of 158 target PCB congeners in Aroclor® mixes are eluted

singly from an Rtx®-PCB column.

PCB# s/m*

1

s

2

s

3

s

4

m

5

s

6

s

7

s

8

s

9

s

10

m

11

m

12

m

13

m

15

s

16

s

17

m

18

s

19

s

20

m

21

m

22

s

23

m

24

m

25

s

26

s

27

m

28

s

29

s

31

m

32

s

33

m

34

s

PCB# s/m*

35

s

37

s

40

s

41

s

42

s

43

s

44

s

45

s

46

s

47

s

48

s

49

s

51

m

52

s

53

m

54

m

55

s

56

m

57

m

59

s

60

m

63

s

64

s

66

s

67

s

70

s

71

s

74

s

75

s

76

m

77

m

81

s

PCB# s/m*

82

s

83

s

84

m

85

s

86

m

87

m

88

m

89

m

90

m

91

s

92

s

93

m

94

m

95

m

96

s

97

s

99

m

101

m

102

s

103

s

105

m

109

m

110

s

114

s

115

s

117

m

118

m

119

s

122

s

123

m

124

s

125

m

PCB# s/m*

126

s

128

m

129

s

130

s

131

m

132

s

133

s

134

s

135

s

136

m

137

s

138

s

139

s

141

s

144

s

146

s

147

m

149

m

151

s

153

s

154

m

156

s

157

s

158

s

163

s

164

s

166

s

167

s

169

s

170

s

171

s

172

s

PCB# s/m*

173

s

174

m

175

s

176

m

177

s

178

s

179

s

180

s

183

s

185

s

187

s

189

s

190

m

191

s

193

s

194

s

195

s

196

m

197

s

198

s

199

s

200

s

201

s

202

s

203

s

205

s

206

s

207

s

208

s

209

s

For additional PCB congener mixes, and Aroclor

®

reference

materials, please see our current catalog, or visit our website.

References

1. Frame, G., J. Cochran, and S., Bowadt,

Complete PCB Congener

Distributions for 17 Aroclor Mixtures Determined by 3 HRGC Systems

Optimized for Comprehensive, Quantitative, Congener-Specific

Analysis

J. High Res. Chromatogr. 19, Dec. 1996, pp. 657-668.

2. Executive Summary,

Assessment of the Health Risk of Dioxins:

Re-evaluation of the Tolerable Daily Intake (TDI)

, WHO Consultation,

May 25-29, 1998, Geneva Switzerland. See:

http://www.who.int/ipcs/publications/en/exe-sum-final.pdf

Figure 2

Excellent separation and peak shape for PCBs in three

Aroclor® mixes, using an Rtx®-PCB column.

2,4,4' (BZ #28)

2,2',5,5' (BZ #52)

2,2',4,5,5' (BZ #101)

2,3',4,4',5 (BZ #118)

2,2',3,4,4',5' (BZ #138)

2,2',4,4',5,5' (BZ #153)

2,2',3,4,4',5,5' (BZ #180)

PCB Congener Standard #2

10µg/mL each in isooctane, 1mL/ampul

cat. # 32294 (ea.)

$30

Rtx

®

-PCB (fused silica)

The maximum temperatures listed are for 15- and 30-meter

lengths. Longer lengths may have a slightly reduced maximum

temperature.

ID df (µm)

temp. limits

length cat. #

price

0.18mm 0.18 30°C to 320/340°C 20-Meter 41302

$360

0.18mm 0.18 30°C to 320/340°C 60-Meter 41304

$470

0.25mm 0.25 30°C to 320/340°C 30-Meter 13223

$445

0.25mm 0.25 30°C to 320/340°C 60-Meter 13226

$470

0.32mm 0.50 30°C to 320/340°C 30-Meter 13239

$470

*s - compound eluted singly; m - compound eluted with one or more other congeners.

Column:

Rtx

®

-PCB 40m, 0.18mm ID, 0.18µm (cat.# 41303)

Sample:

300ng/mL Aroclor

®

1242/1254/1262 in hexane: Aroclor

®

1242 (cat.# 32009),

Aroclor

®

1254 (cat.# 32011), Aroclor

®

1262 (cat.# 32409)

Inj.:

1.0µL splitless (hold 0.75 min.), 4mm single gooseneck inlet liner (cat.# 20983)

Inj. temp.:

230°C

Carrier gas:

hydrogen, constant pressure

Linear velocity: 40cm/sec. @ 100°C

Oven temp.:

100°C (hold 1 min.) to 200°C @ 30°C/min., to 320°C @ 2°C/min. (hold 1 min.)

Det.:

ECD @ 330°C

GC_EV00768

min.

min.