Table of Contents Table of Contents
Previous Page  210 / 298 Next Page
Information
Show Menu
Previous Page 210 / 298 Next Page
Page Background

• 5 •

www.restekcorp.com

2003

Volume 2

800-356-1688

Rtx

®

-VMS, 30m, 0.25mm ID, 1.4µm (cat.# 19915)

Sample:

calibration mixes: cat.# 30475 (ampul 1 + ampul 2), 30465, 30006, 30042;

non-oxygenated unleaded gasoline (custom) internal / surrogate

standards: cat.# 30240, 30074

Purge and Trap Conditions

O.I. 4560 Purge and Trap Concentrator

Sample:

10mL

Sample Temp.:

40°C

Trap:

#10 (Tenax

®

/silica gel/carbon molecular sieve)

Trap Temp.:

purge: 20°C; desorb: 190°C; bake: 210°C

Purge:

11 min., 38mL/min.

Desorb:

1.0 min., 32mL/min.

Bake:

10 min.

Chromatography

Inj. Temp.:

250°C, split 25:1

Carrier Gas:

helium, constant flow

Flow Rate:

1.3mL/min.

Dead Time:

1.47 min. @35°C

Oven Temp.:

35°C (hold 7 min.) to 90°C @4°C/min. (no hold)

to 220°C @45°C/min. (hold 1 min.)

Det.:

Agilent 5971A MS

Scan Range:

35–260 amu

Tune:

PFTBA/BFB

GC_EV00679

Acknowledgement: purge and trap courtesy of O.I. Analytical.

Figure 1

— Detect trace oxygenates, using an Rtx

®

-VMS column.

5ppb oxygenates in 1ppm non-

oxygenated gasoline.

area of enlargement

US EPA Underground Storage

Tank (UST) Monitoring Program

Reference publications

for recommended methods

Helpful checklists for the latest state and EPA UST methods:

– analytical reference materials

– sample preparation supplies

– chromatography columns and accessories

Conveniently organized by method—easy setup / easy reorder of consumables

In the late 1980s the US Environmental Protection

Agency (US EPA) established the Office of

Underground Storage Tanks (OUST) to enforce fed-

eral laws on environmental contamination from

petroleum products. Underground Storage Tank

(UST) systems installed before December 22, 1988

had no protection against spills or overfills, and

were likely to corrode and leak. OUST mandated

that by December 22, 1998, all UST systems were to

be prevented from contaminating nearby groundwa-

ter and soil. Existing systems were to be protected

from spills, overfills, and corrosion, or replaced

with new systems incorporating such protection.

Many of the unprotected UST systems have been prop-

erly treated, but the need for monitoring UST systems

persists. OUST has been actively enforcing federal UST

regulations.

OUST has recommended specific EPA methods for UST

applications. A majority of the states still use these

methods, but many states have developed methods of

their own for UST analysis.

To help laboratories comply with and use the appropri-

ate analytical procedures, Restek has been active in fol-

lowing EPA and state guidance. Based on our knowl-

edge and experience with these methods, our chemists

have developed lists of the appropriate chromatograph-

ic tools, and formulated analytical reference products,

to help ensure successful analyses. Comprehensive list-

ings of quality chromatographic columns, analytical

reference materials, and sample preparation products

for latest state methods are featured in an expanding

group of Restek publications. In these listings, you will

find everything you need to quickly set-up or reorder

consumables for UST methods.

Request comprehensive product listings

for latest state UST methods

Reference Standards

Pattern Recognition Standards

GRO – gasoline composites, including

composite weathered gasoline standards

DRO - including a composite arctic range

diesel standard

RRO - motor oil composites, including

composite used motor oil

Weathered fuels and oils

Mineral oils

Military fuels

State-specific UST calibration formulations

Retention time marker standards

Internal standards

Surrogate standards

Reference materials conveniently organized by

method number

Custom mixtures available - ask us for a quote

For copies of these publications, fill out the reply

card at the center of this

Advantage

. Select from

these current UST publications: AK - CA - FL - IA -

MA - TX - WI - Northwest (WA / OR) or USEPA

For custom mixes, use the quote form in our

general catalog, or on our web site

(www.restekcorp.com)

, or fax 814-355-2895.

Remember: we will be happy to provide a

quote on any custom reference mixture,

column, or other consumable you need!