• 4 •
www.restekcorp.com800-356-1688
For years column manufacturers have proclaimed
that packed GC columns have gone the way of the
dinosaurs. While packed columns do not fill every
need, in some situations their use is dictated by
methodology, and, for some analysts, they are the
column of preference. Restek innovations have
brought new life to the “expired” packed column in
all three aspects of column technology: the support,
the phase, and the tubing. Silcoport
™
support pro-
vides unsurpassed inertness for trace analyses. Our
bonded phase packings are a revolution in packed
column technology. They significantly shorten con-
ditioning times, greatly reduce column bleed, and
prolong column lifetimes. SilcoSmooth
™
tubing
combines the inertness of glass with the durability
of stainless steel.
The great sensitivity of modern detection systems
and a progressing need to reduce detection limits
place challenging demands on a chromatography
column. Silcoport
™
diatomaceous earth support is
the modern solid support that we developed to
meet these demands. Unlike conventional DMDCS
by Neil Mosesman, GC Columns Product Marketing Manager
Packed Column Technology
Has New Life
With Restek Innovations
✔
Optimized tubing and support ensure unsurpassed inertness for trace analyses.
✔
Bonded phases shorten conditioning times, greatly reduce bleed, and prolong
column lifetimes.
deactivation, we use a proprietary fused silica deac-
tivation technology and a special mixture of deacti-
vants to ensure the greatest inertness (Figure 1)
without changing the polarity of the stationary
phase. Each batch of support is carefully tested to
confirm a uniform particle size distribution that
ensures columns with maximum efficiency.
By applying our experience in stationary phase syn-
thesis in conjunction with our unique Silcoport
™
packing deactivation process we create completely
bonded packing materials. To encompass a wide
range of applications, we offer Rtx
®
-1 and Rtx
®
-5,
bonded methyl silicone phases, and Stabilwax
®
, a
bonded Carbowax
®
phase. Each phase is completely
cross-linked on Silcoport
™
support. In side-by-side
comparisons with conventional nonbonded methyl
silicone phase columns, Rtx
®
-1 and Rtx
®
-5 columns
have lower bleed, improved peak shape, and longer
useful lives (Figure 2). Evaluations with an Rtx
®
-1
column show retention times are repeatable after
only 30 minutes of conditioning.
If your analysis involves reactive compounds, you
probably have used fragile, inflexible glass
columns, but now you can do better. Made from
ultra-smooth, seamless 304 stainless steel, and
treated with our innovative Silcosteel
®
deactivation
process, SilcoSmooth
™
tubing combines the inert-
ness of glass with the strength and flexibility of
stainless steel. SilcoSmooth
™
tubing can replace
glass tubing in virtually any application. For analy-
ses of ppb levels of sulfur-containing compounds,
use Sulfinert
™
tubing packed with Rt-XLSulfur
™
packing. For undemanding applications we can
make columns from conventional tubing: stainless
steel, Hastelloy
®
, nickel, copper, or Teflon
®
.
In combination, Silcoport
™
support, our bonded
phase packings, and SilcoSmooth
™
tubing make
packed column GC a viable alternative in many
applications in which the technique had been
endangered. If you use packed columns, and think
that you have to live with limitations, call us. We
can provide the column that will give you the sepa-
ration you need, but with convenience, inertness,
and column lifetimes you never expected from a
packed column.
2
1
0
Non-Bonded
Methyl Silicone
Bleed interferes
with analysis
18 17 16 15 14
13
12
11 10 9 87654 1
32
Bonded Rtx
®
-1
Low bleed after 170
cycles to 350°C!
GC_PC00369
Ordering Information
| Bonded Packed Column Stationary Phases:
Stainless Steel Tubing
SilcoSmooth
™
Tubing
Liquid Phases Bonded
L
OD ID cat.#*
L
OD ID cat.#*
on 100/120 Silcoport
™
P
(ft.)
(in.)
(mm)
(m)
(in.)
(mm)
3% Rtx
®
-1
6
1
/
8
2.1 80441-
2
1
/
8
2 80401-
10% Rtx
®
-1
6
1
/
8
2.1 80442-
2
1
/
8
2 80405-
20% Rtx
®
-1
6
1
/
8
2.1 80443-
2
1
/
8
2 80409-
3% Rtx
®
-5
6
1
/
8
2.1 80444-
2
1
/
8
2 80477-
10% Rtx
®
-5
6
1
/
8
2.1 80445-
2
1
/
8
2 80478-
20% Rtx
®
-5
6
1
/
8
2.1 80446-
2
1
/
8
2 80479-
5% Rtx
®
-Stabilwax
®
6
1
/
8
2.1 80447-
2
1
/
8
2 80415-
10% Rtx
®
-Stabilwax
®
6
1
/
8
2.1 80448-
2
1
/
8
2 80416-
20% Rtx
®
-Stabilwax
®
6
1
/
8
2.1 80449-
2
1
/
8
2 80417-
Rtx
®
-1 SimDist 2887
25"
1
/
8
2.1 80450
25"
1
/
8
2
80000
3 4 5 6 7 8 9 10 11
12
13
14 15 16
17 18
10
20
30 min.
0
10
20
30 min.
Figure 2
Bonded packed columns exhibit longer life-
times than nonbonded columns.
1. C5
2. C6
3. C7
4. C8
5. C9
6. C10
7. C11
8. C12
9. C14
10. C16
11. C18
12. C20
13. C24
14. C28
15. C32
16. C36
17. C40
18. C44
Rtx
®
-1 SimDist 2887 25" x
1
/
8
"
Silcosteel
®
column (cat.# 80000)
1.0µL direct injection of 1-12%
(w/w) each component cat.# 31647
(1% each listed analyte in CS
2
) and
cat.# 31675 (5% each, neat) meet
requirements of ASTM D2887-01.
Oven temp.:
35°C to 350°C @
10°C/min. (hold 5 min.)
Inj. & det. temp.:
350°C
Carrier gas:
helium @ 25mL/min.
FID sensitivity:
256 x 10
-11
AFS
Figure 1
A trace level analysis of pesticides, including labile endrin and DDT, demonstrates the
inertness of Silcoport
™
support.
1
2
GC_EV00370
1. aldrin
2. 4,4'-DDE
3. endrin
4. 4,4'-DDD
5. 4,4'-DDT
6. endrin aldehyde
7. endrin ketone
1.5% Rt-608Pkd 2m, 2mm ID (cat.# 80221-)
Concentration:
50pg each analyte on-column
Oven temp.:
200°C isothermal
Inj. & det. temp.:
250°C
Det.:
ECD
Column flow:
nitrogen, 30cc/min.
5
10
15
min.
3
4
5
6
7