Chromatography Columns 2013+ - page 157

100
GCCOLUMNS |
APPLICATION-SPECIFICCOLUMNS
Environmental
Rapidanalysisofvolatileorganics inUSEPAMethod8260B,onanRtx
®
-VMScolumn.
min.
2
4
6
8
10
2
1
3
4
5
6
7
8
9 10
11
13
14
15
16
17
18
19-21
22
23
24
25
26-28
29-32
33,34
35
36 37
38
39
40
41
42
43
44
45
46 47
48
49
50
51
52
53
54,55
56
57
58
59
60
61
62,
63
64,65
66,67
68,69
70
71,72
73
74
75
76
77
78
79,80
81
82,83
84
85
86
87
88,89
90
91
92
93
94
95
96
97
GC_EV00428
12
Column:
Rtx
®
-VMS, 20m, 0.18mm ID, 1.00µm (cat.# 49914)
Conc.:
10ppb in 5mL of ROwater
unless otherwise noted; ketones at 2.5X
Concentrator:
Tekmar LSC-3100 Purge andTrap
Trap:
Vocarb 3000 (type K)
Purge:
11min.@ 40mL/min. (ambient temperature)
Dry purge:
1min.@ 40mL/min.
Desorb preheat:
245°C
Desorb:
250°C for 2min., flow 40mL/min.
Bake:
260°C for 8min.
Interface:
0.53mm ID Silcosteel
®
tubing transfer line
1:40 split at injection port. 1mm ID liner.
Oven temp.:
50°C (hold 4min.) to 100°C@ 18°C/min. (hold 0min.)
to 230°C@ 40°C/min. (hold 3min.)
Carrier gas:
helium@~1.0mL/min. constant flow
Adjust dichlorodifluoromethane to a retention time of 1.03min.@ 50°C.
Detector:
Agilent 5973MSD
Scan range:
35-300amu
VolatileOrganicsAnalysis
For peak listing, seepage550.
Rtx®-VMSColumns
(fusedsilica)
(proprietaryCrossbond®phase)
• Application-specific columns for volatile organic pollutants byGC/MS.
• Complete separationof USEPAMethod8260B compounds in less than10minutes.
• Stable to260 °C.
• Noknown equivalent phases.
Rtx®-VMS columns offer lower bleed, better selectivity, and overall faster analysis for
separating volatile organic compounds, such as those listed inUSEPAMethod 8260B.
The Rtx®-VMS stationary phase is a highly stable polymer that provides outstanding
analysis of volatile compounds, in combination with sensitive ion traps and Agilent
5973mass spectrometers. 0.18 and 0.25mm ID columns allow sample splitting at the
injectionport,eliminating theaddedexpenseandmaintenanceof a jet separator.A0.45
mmor 0.53mm ID column canbedirectly connected to thepurge& trap transfer line
in a system equippedwith a jet separator.
ID
df
temp. limits
30-Meter
60-Meter
75-Meter
0.25mm 1.40µm -40 to 240/260°C 19915
19916
0.32mm 1.80µm -40 to 240/260°C 19919
19920
0.45mm 2.55µm -40 to 240/260°C 19908
19909
0.53mm 3.00µm -40 to 240/260°C 19985
19988
19974
ID
df
temp. limits
20-Meter
40-Meter
0.18mm 1.00µm -40 to 240/260°C 49914
$450
49915
$755
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
Mar 2011
1...,147,148,149,150,151,152,153,154,155,156 158,159,160,161,162,163,164,165,166,167,...