Chromatography Columns 2013+ - page 135

78
GCCOLUMNS |
APPLICATION-SPECIFICCOLUMNS
Petroleum & Petrochemical
Lowbleed,highefficiencyMXT®-1HTSimDistcolumnsoutperformcompetitors (ASTMD6352conditions).
Higherefficiencymeans:
Greater resolution; analyzemore samples
beforemethod criteriaare reached.
Assuredmethodperformance.
Lowerbleedmeans:
Longer column lifetime.
More stable calibrations.
Accurateboilingpoint determinations.
RESTEKADVANTAGE:
Longer column lifetimeand
moreaccuratedata!
RESTEKADVANTAGE:
Runmore sampleswithinmethod
specifications!
0
10
20
30
40
Time (min)
0
10
20
30
40
Time (min)
0
10
20
30
40
Time (min)
GC_PC1149
GC_PC1151
GC_PC1150
Varian,5mx0.53mmx0.17μm
Agilent/ J&W,5mx0.53mmx0.15μm
Restek,5mx0.53mmx0.2μm
Bleed=14pA
Bleed=61pA
Bleed=57pA
C50/C52
R=2.89
C50/C52
R=1.81
C50/C52
R=1.84
similar
phases
DB-1HT, CP-HT-SimdistCB
MXT®-1HTSimDistColumn
(Siltek® treatedstainlesssteel)
(nonpolar phases)
• Stableup to450 °C—lowest bleed for longest column lifetime.
• Reliablymeet allASTMD6352,D7169, andD7500 specifications.
• 100%dimethyl polysiloxane phase allows easy comparisons tohistorical data.
Accurate boiling point determination for medium and heavy fractions using GC
simulated distillation requires columns and phase polymers that are robust enough
towithstandhigh temperatureswithout significant degradation.Metal columns are
a better alternative than fused silica, and theMXT®-1HT SimDist columns are the
lowest bleed, highest efficiency columns available, outperforming other metal
columns for criticalmethodparameters.
SimulatedDistillation (C44-C100) Analysis
ASTM
Method
D2887
D7213
(D2887-ext)
D3710
D5307
D6352
D7500
D7169
Hydrocarbon
Range
C5 - C44
C5 - C60
gasoline
up to C14
crude
up to C42
C10 - C90
C7 - C110
C5 - C100
cat.#
70131
70132
70131
70115
70112
70132
70115
70112
70115
70112
70115
70112
70115
Configuration
5m x 0.53mm, 0.88µm
10m x 0.53mm, 2.65µm
5m x 0.53mm, 0.88µm
5m x 0.53mm, 0.20µm
5m x 0.53mm, 0.10µm
10m x 0.53mm, 2.65µm
5m x 0.53mm, 0.20µm
5m x 0.53mm, 0.10µm
5m x 0.53mm, 0.20µm
5m x 0.53mm, 0.10µm
5m x 0.53mm, 0.20µm
5m x 0.53mm, 0.10µm
5m x 0.53mm, 0.20µm
MethodRecommendedColumns
NEW!
ID
df
temp. limits
5-Meter
10-Meter
0.53mm
0.10µm
-60 to 430/450°C
70112
0.20µm
-60 to 430/450°C
70115
0.21µm
-60 to 430/450°C
70118
0.88µm
-60 to 400/430°C
70131
70134
1.00µm
-60 to 380/400°C
70130
1.20µm
-60 to 380/400°C
70119
2.65µm
-60 to 360/400°C
70132
5.00µm
-60 to 360/400°C
70133
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
Mar 2011
1...,125,126,127,128,129,130,131,132,133,134 136,137,138,139,140,141,142,143,144,145,...