Chromatography Columns 2013+ - page 138

81
GCCOLUMNS |
APPLICATION-SPECIFICCOLUMNS
Petroleum & Petrochemical
Biodiesel FuelsAnalysis
Integra-Gap®
technology
• Built-in retentiongap.
• Eliminates connector and leaks.
• Extendsanalytical column lifetime.
RetentionGap
LiquidPhase
free
literature
Biodiesel Solutions:
InnovativeProducts
forSimple,Reliable
BiodieselAnalysis
Downloadyour free
copy from
lit. cat.#580207
DerivatizedB100and internal standardsonanMXT®-BiodieselTGcolumnwith2mx0.53mm IDcoupled
retentiongap, according toASTMD6584.
GC_PC00935
monoglycerides
triglycerides
Column:
MXT
®
-BiodieselTG, 10m, 0.32mm ID, 0.1µm
with 2m x 0.53mm retention gap (cat.# 70290)
Sample:
B100+ IS butanetriol & tricaprin derivatized
withMSTFA as per ASTMD-6584
Inj.:
1.0µL cool on-column
Inj. temp.:
oven track
Carrier gas:
hydrogen, constant flow
Flow rate:
4mL/min.
Oven temp.:
50°C (hold 1min.) to 180°C@ 15°C/min.,
to 230°C@ 7°C/min., to 430°C@ 30°C/min.
(hold 5min.)
Det.:
FID@ 430°C
butanetriol (IS)
glycerin
tricaprin (IS)
diglycerides
Noteperfectpeak
shapeof solvent,with
low-dead-volume
MXT®connector.
Rtx®-BiodieselTGColumns
(fusedsilica)
• Linearity for all reference compounds exceedsmethod requirements.
• Alumaseal® connector provides leak-free connection; guard column
extends column life.
• Low columnbleed at high temperatures.
• For glycerine and glycerides analysis, according toASTMD6584 and
EN14105methods.
*Total column length= 16meters.
**Connectedwith low-dead-volumeMXT connector.
MXT®-BiodieselTGColumns
(Siltek® treatedstainlesssteel)
• Fast analysis times and sharpmono-, di-, and triglyceride peaks.
• Stable at 430 °C for reliable, consistent performance.
• Integra-Gap®built-in retention gapon0.53mm ID column eliminates
column coupling completely.
Description
temp. limits
cat.#
price
10m, 0.32mmID, 0.10µm
to 330/380°C 10292
10m, 0.32mmID, 0.10µmwith 2m x 0.53mm IDRetentionGap
to 330/380°C 10291
15m, 0.32mmID, 0.10µm
to 330/380°C 10294
15m, 0.32mmID, 0.10µmwith 2m x 0.53mm IDRetentionGap
to 330/380°C 10293
Description
temp. limits
cat.#
price
14m, 0.53mmID, 0.16µmwith 2m Integra-Gap*
-60 to 380/430°C 70289
10m, 0.32mmID, 0.10µm
-60 to 380/430°C 70292
10m, 0.32mmID, 0.10µmwith 2m x 0.53mmRetentionGap**
-60 to 380/430°C 70290
15m, 0.32mmID, 0.10µm
-60 to 380/430°C 70293
15m, 0.32mmID, 0.10µmwith 2m x 0.53mmRetentionGap**
-60 to 380/430°C 70291
2mx 0.53mmMXT BiodieselTG
70294
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
Mar 2011