Table of Contents Table of Contents
Previous Page  518 / 628 Next Page
Information
Show Menu
Previous Page 518 / 628 Next Page
Page Background

516

www.restek.com

1-800-356-1688 or 1-814-353-1300

REFERENCE STANDARDS |

ENVIRONMENTAL

Hydrocarbons

Hydrocarbons, Petroleum,

cont.

Retention Time Markers

25 µg/mL each in methylene chloride, 1 mL/ampul

cat.# 31200 (ea.)

n

-Hexane (C6) (110-54-3)

n

-Decane (C10) (124-18-5)

n

-Dodecane (C12) (112-40-3)

n

-Tetracosane (C24) (646-31-1)

n

-Octacosane (C28) (630-02-4)

n

-Triacontane (C30) (638-68-6)

n

-Tetracontane (C40) (4181-95-7)

Used during initial sample screening to determine retention

time windows for each petroleum product. Gasoline generally

elutes in the window from C6 to C10 (or C12), and diesel fuel

from C10 (or C12) to C24 (or C28). Retention above C24 (or

C28) indicates oil or lubricant contamination.

Leaking Underground Storage Tank Retention Time

Standard

(7 components)

1,000 µg/mL each in P&T methanol, 1 mL/ampul

cat.# 30483 (ea.)

n

-Hexane (C6) (110-54-3)

n

-Decane (C10) (124-18-5)

n

-Dodecane (C12) (112-40-3)

Retention Time Marker

(3 components)

200 µg/mL each in pentane, 1 mL/ampul

cat.# 31698 (ea.)

n

-Hexane (C6) (110-54-3)

n

-Dodecane (C12) (112-40-3)

n

-Octacosane (C28) (630-02-4)

n

-Pentatriacontane (C35) (630-07-9)

TNRCC 1005 Retention Time Markers Mix

(4 components)

200 µg/mL in pentane, 1 mL/ampul

cat.# 31814 (ea.)

n

-Hexane (C6) (110-54-3)

n

-Heptane (C7) (142-82-5)

n

-Octane (C8) (111-65-9)

n

-Decane (C10) (124-18-5)

n

-Dodecane (C12) (112-40-3)

n

-Hexadecane (C16) (544-76-3)

n

-Heneicosane (C21) (629-94-7)

n

-Octacosane (C28) (630-02-4)

n

-Pentatriacontane (C35) (630-07-9)

TNRCC 1006 Retention Time Marker Mix

(9 components)

1,000 µg/mL in methylene chloride, 1 mL/ampul

cat.# 31819 (ea.)

n

-Hexane (C6) (110-54-3)

n

-Decane (C10) (124-18-5)

n

-Pentacosane (C25) (629-99-2)

n

-Hexatriacontane (C36) (630-06-8)

Retention Time Marker—Alaska

(4 components)

200 µg/mL each in pentane, 1 mL/ampul

cat.# 31639 (ea.)

n

-Hexane (C6) (110-54-3)

n

-Octane (C8) (111-65-9)

n

-Decane (C10) (124-18-5)

n

-Dodecane (C12) (112-40-3)

n

-Hexadecane (C16) (544-76-3)

n

-Heneicosane (C21) (629-94-7)

n

-Octacosane (C28) (630-02-4)

n

-Pentatriacontane (C35) (630-07-9)

n

-Hexatriacontane (C36) (630-06-8)

Alternate Boiling Point/Carbon Number Distribution

Marker Stock Standard

(9 components)

2,000 µg/mL each in methanol, 1 mL/ampul

cat.# 30611 (ea.)

n

-Hexane (C6) (110-54-3)

n

-Decane (C10) (124-18-5)

Toluene (108-88-3)

CCME F1 Retention Time Marker

(3 components)

Satisfaction

Guaranteed

True Blue Performance

Exceptionally inert Sky® inlet liners with

state-of-the-art deactivation improve

trace-level analysis—

and now come

with a 100% satisfaction guarantee!*

* For details on our 100% satisfaction guarantee, visit

www.restek.com/sky www.restek.com/ s

ky

See

page 193–202 .