83

FAMEs (

cis/trans

isomers) on Rt®-2560

GC COLUMNS |

APPLICATION-SPECIFIC COLUMNS

Foods, Flavors, & Fragrances

FAME Analysis (

cis

/

trans

)

32

33

34

35

1

2

4

5

3 6

7

8

36

37

38

39

40

41

42

GC_FF00652

Column

Rt®-2560, 100 m, 0.25 mm

ID, 0.20 µm (cat.# 13199)

Sample

cis

/

trans

FAME mix

(cat.# 35079)

Diluent:

Methylene chloride

Conc.:

10 mg/mL total FAMEs

Injection

Inj. Vol.:

1 µL split (split ratio 20:1)

Liner:

Splitless (4 mm ID)

(cat.# 20814)

Inj. Temp.:

225 °C

Oven

Oven Temp.:

100 °C (hold 4 min) to 240 °C

at 3 °C/min (hold 10 min)

Carrier Gas

H

2

, constant flow

Flow Rate:

1.2 mL/min

Detector

FID@ 250 °C

Peaks

Conc.

(wt.%)

1. C18:0 methyl stearate

20.0

2. C18:1 methyl petroselaidate (

trans

-6)

8.0

3. C18:1 methyl elaidate (

trans

-9)

10.0

4. C18:1 methyl transvaccenate (

trans

-11)

12.0

5. C18:1 methyl petroselinate (

cis

-6)

8.0

6. C18:1 methyl oleate (

cis

-9)

10.0

7. C18:1 methyl vaccenate (

cis

-11)

12.0

8. C18:2 methyl linoleate (

cis

-9,12)

20.0

Excellent resolution of

cis

&

trans

isomers!

FAMEs (Marine Oil Standard) on FAMEWAX

FAME Analysis (Polyunsaturated)

GC_FF00499

Column

FAMEWAX, 30 m, 0.32 mm ID, 0.25 µm

(cat.# 12498)

Sample

Marine oil FAME mix (cat.# 35066)

Diluent:

Isooctane

Conc.:

10,000 µg/mL (total FAMEs; see breakdown

in peak list)

Injection

Inj. Vol.:

1 µL split (split ratio 100:1)

Inj. Temp.:

250 °C

Oven

Oven Temp.:

195 °C to 240 °C at 5 °C/min (hold 1 min)

Carrier Gas

H

2

, constant flow

Flow Rate:

3 mL/min

Detector

FID@ 275 °C

Peaks

Conc.

(µg/mL)

1. C14:0

600

2. C14:1

100

3. C16:0

1,600

4. C16:1

500

5. C18:0

800

6. C18:1 (oleate)

1,300

7. C18:1 (vaccenate) 400

8. C18:2

200

9. C18:3

200

10. C20:0

100

11. C20:1

900

12. C20:2

100

13. C20:4

300

14. C20:3

100

15. C20:5

1,000

16. C22:0

100

17. C22:1

300

18. C24:0

100

19. C22:6

1,200

20. C24:1

100

Column engineered for

optimal resolution.

FAMEs Analyses

High-Resolution GC Analyses

of Fatty Acid

Methyl Esters

lit. cat.# 59584B

www.restek.com

Download your

free copy from

Rt®-2560 Column

(fused silica)

(highly polar phase; biscyanopropyl polysiloxane—not bonded)

• Application-specific column for

cis

/

trans

FAMEs.

• Stable to 250 °C.

Because the Rt®-2560 stationary phase is not bonded, it should not be solvent rinsed.

similar phases

HP-88, CP-Sil 88, SPB-2560

100-Meter

ID

df

temp. limits

cat.#

price

0.25 mm 0.20 µm

20 to 250 °C

13199

FAMEWAX Columns (USP G16)

(fused silica)

(polar phase; Crossbond® polyethylene glycol)

• Application-specific columns for FAMEs, specially tested with a FAME mixture.

• Temperature range: 20 °C to 250 °C.

The elution order of polyunsaturated FAMEs on FAMEWAX columns is comparable to

that on other Carbowax® columns, but baseline resolution is achieved in significantly

less time.

similar phases

Select FAME, Omegawax

30-Meter

ID

df

temp. limits

cat.#

price

0.25 mm 0.25 µm 20 to 240/250 °C

12497

0.32 mm 0.25 µm 20 to 240/250 °C

12498

0.53 mm 0.50 µm

20 to 250 °C