GC COLUMNS |

APPLICATION-SPECIFIC COLUMNS

Clinical, Forensic, & Toxicology

Rtx®-BAC Plus 1 Columns

(fused silica)

Rtx®-BAC Plus 1/Rtx®-BAC Plus 2 Columns

• Optimized column selectivities guarantee resolution of ethanol, internal standards,

and frequently encountered interferences.

• Robust and reproducible column chemistry ensures longer column lifetime and

consistent results.

• Stable to 260 °C.

These application-specific columns for blood alcohol analysis baseline separate all

critical compounds—including ethanol, methanol, acetone,

tert

-butanol, acetalde-

hyde, isopropanol, and

n

-propanol—in less than 2 minutes. Every Rtx®-BAC Plus 1

and Rtx®-BAC Plus 2 column is qualified with a test mix containing these important

BAC target compounds to ensure reproducibility.

These columns baseline separate all blood alcohol compounds in blood, breath, or

urine, in less than 2 minutes, under isothermal conditions. Isothermal analysis in-

creases productivity by eliminating the need for oven cycling. Confirmation is easily

achieved with this tandem set because there are two elution order changes between

the columns.

Rtx®-BAC Plus 2 Columns

(fused silica)

Blood Alcohol Analysis

Blood Alcohol Analysis on Rtx®-BAC Plus 1 and Rtx®-BAC Plus 2

Time (min)

0.5

0.75

1

1.25

1.5

1.75

2

2.25

2.5

2.75

1

2

3

4

5

6

7

Blood Alcohol Analysis on Rtx®-BAC Plus 1

GC_CF1153

Column

Rtx®-BAC Plus 1, 30 m, 0.32 mm ID, 1.8 µm (cat.# 18004)

Sample

BAC resolution control standard n-P (cat.# 36010)

BAC resolution control standard t-B (cat.# 36011)

Diluent:

Water

Conc.:

50 µL of each standard were diluted in 900 µL water in a

20 mL headspace vial.

Injection

Headspace-loop split (split ratio 50:1)

Liner:

1 mm ID straight inlet liner (cat.# 20972)

Headspace-Loop

Inj. Port Temp.:

200 °C

Instrument:

Tekmar HT3

Inj. Time:

3 min

Transfer Line

Temp.:

125 °C

Valve Oven Temp.: 125 °C

Standby flow

rate:

50 mL/min

Sample Temp.:

60 °C

Sample Equil.

Time:

5 min

Vial Pressure:

30 psi

Pressurize Time: 1 min

Loop Pressure:

20 psi

Loop Fill Time:

1 min

Oven

Oven Temp.:

40 °C (hold 3 min)

Carrier Gas

He, constant flow

Linear Velocity:

80 cm/sec @ 40 °C

Detector

FID@ 240 °C

Make-up Gas

Flow Rate:

30 mL/min

Make-up Gas

Type:

N

2

Instrument

Agilent/HP6890 GC

Notes

Headspace concentrator courtesy of Teledyne Tekmar,

Mason, OH.

Peaks

t

R

(min)

Conc.

(µg/mL)

1. Methanol

0.912

100

2. Acetaldehyde

0.967

100

3. Ethanol

1.158

100

4. Isopropanol

1.420

100

5. Acetone

1.548

100

6.

tert

-Butanol

1.688

50

7. 1-Propanol (

n

-Propanol)

1.969

50

Time (min)

0.5

0.75

1

1.25

1.5

1.75

2

2.25

2.5

2.75

1

2

3

4

5

6

7

Blood Alcohol Analysis on Rtx®-BAC Plus 2

GC_CF1154

Peaks

t

R

(min)

Conc.

(µg/mL)

1. Acetaldehyde

0.809

100

2. Methanol

0.861

100

3. Ethanol

1.034

100

4. Acetone

1.119

100

5. Isopropanol

1.181

100

6.

tert

-Butanol

1.304

50

7. 1-Propanol (

n

-Propanol)

1.658

50

free literature

Rtx®-BAC Plus 1 and

Rtx®-BAC Plus 2 Columns

Advanced Technology for Fast,

Reliable Measurement

of Alcohol in Blood

Download your

free copy from

lit. cat.#

CFBR1538-UNV

www.restek.com

30-Meter

ID df

temp. limits

cat.#

price

0.32 mm 1.80 µm -20 to 240/260 °C 18004

0.53 mm 3.00 µm -20 to 240/260 °C 18005

30-Meter

ID df

temp. limits

cat.#

price

0.32 mm 0.6 µm -20 to 240/260 °C 18006

0.53 mm 1.0 µm -20 to 240/260 °C 18007

similar phases

DB-ALC1, ZB-BAC1

DB-ALC2, ZB-BAC2