Water and Ethanol in Acetone on Rt®-Q-BOND

GC COLUMNS |

PLOT COLUMNS

Fused Silica Porous Polymer Columns

Our porous polymer PLOT columns

are not moisture sensitive, making

them ideal for applications where

moisture is of major concern.

most

polar

least

polar

Q-BOND

QS-BOND

S-BOND

U-BOND

Restek porous

polymer PLOT

columns cover a

wide range of

polarities

1.6

Time (min)

1.8

2.0

2.2

2.4

2.6

2.8

3.0

3.2

3.4

1.935

2.215

2.063

2.527

2.723

GC_PC01075

Colum

n

Rt®-Q-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19742)

Sample

Diluent:

Acetone

Conc.:

0.5%Water and ethanol

Injection

Inj. Vol.:

3 µL split (split ratio 11:1)

Liner:

Splitless taper (4 mm) w/wool (cat.# 22405)

Inj. Temp.:

250 °C

Oven

Oven Temp.:

200 °C (hold 4 min)

Carrier Gas

He, constant linear velocity

Linear Velocity:

28.7 cm/sec @ 200 °C

Detector

TCD@ 260 °C

Peaks

tR (min)

1. Methane

1.935

2. Water

2.063

3. Methanol

2.215

4. Ethanol

2.527

5. Acetone

2.723

Rt®-Q-BOND Columns

(fused silica PLOT)

100% divinylbenzene

• Nonpolar PLOT column incorporating 100% divinylbenzene.

• Excellent for analysis of C1 to C3 isomers and alkanes up to C12.

• High retention for CO

2

simplifies gas analysis; CO

2

and methane separated from

O

2

/N

2

/CO. (Note: O

2

/N

2

/CO not separated at room temperature.)

• Use for analysis of oxygenated compounds and solvents.

• Maximum temperature of 300 °C.

similar

phases

HP PLOT Q, CP-PoraPLOT Q, CP-PoraBOND Q,

Supel-Q-PLOT, AT-Q

Porous Polymer Columns

Porous polymers are unique, highly retentive stationary phases with a wide applica-

tion range that are able to elute both polar and nonpolar compounds. They are very

hydrophobic, so water has no impact on retention times and even elutes as a good

chromatographic peak. The Q-BOND is our most nonpolar and widely used porous

polymer column; functional groups can be added to increase polarity (i.e., QS-, S-, and

U-BOND). The process used to manufacture porous polymer PLOT columns causes

the particles to adhere strongly to the walls of the tubing, so there is virtually no par-

ticle generation. You get reproducible performance from column to column, including

selectivity and flow.

15-Meter

30-Meter

ID

df

temp. limits

cat.#

price

cat.#

price

0.25 mm 8 µm to 280/300 °C

19764

19765

0.32 mm 10 µm to 280/300 °C

19743

19744

0.53 mm 20 µm to 280/300 °C

19741

19742