Table of Contents Table of Contents
Previous Page  134 / 629 Next Page
Information
Show Menu
Previous Page 134 / 629 Next Page
Page Background

132

www.restek.com

GC COLUMNS |

PACKED/MICROPACKED COLUMNS

Bonded Stationary Phases

Bonded Stationary Phases

We combined our stationary phase synthesis experience with our unique Silcoport®

packing deactivation process to create bonded phase packings that provide longer life-

times, lower bleed, and shorter conditioning times.

Bonded methyl silicone phases (Rtx®-1 and Rtx®-5 columns) and bonded Carbowax®

phase (Stabilwax® columns) are completely cross-linked on Silcoport® packing. We have

evaluated Rtx®-1 and Rtx®-5 bonded packed column phases side-by-side with non-

bonded phases of comparable polarity; the bonded phases last longer than the equiva-

lent nonbonded packing materials. Table I shows that retention times on an Rtx®-1

bonded packed column are highly repeatable after only 30 minutes of conditioning.

Table I:

Retention data shows the perfect reproducibility of the bonded phase packed

columns with respect to retention times.

Retention Time

Hydrocarbon

Min.

Max.

Mean

Stand. Dev.

C5

0.241

0.243

0.242

0.001

C6

0.493

0.497

0.495

0.002

C10

5.746

5.765

5.752

0.005

C20

18.482

18.491

18.486

0.004

C28

25.093

25.103

25.098

0.004

C40

32.160

32.171

32.166

0.004

C44

34.316

34.328

34.326

0.007

n = 9 columns

Application

Column

Feature

Benefit

ASTMMethod D3606

D3606 Application Column Set,

p. 138

(Column 1: 6' (1.8 m),

1

/

8

" OD, 2.0 mm ID, Rtx-1;

Column 2: 16' (4.9 m),

1

/

8

" OD, 2.0 mm ID,

proprietary packing material)

Excellent separation of ethanol and

benzene.

Reliably meets method requirements.

Refinery gases

2abc Refinery Gas Column Set ,

p. 139

Backflush Column

Optimized three-column set.

(Backflush column sold separately.)

Elutes C5 hydrocarbons before C1-C4

hydrocarbons for optimized resolution.

Unsaturated light hydrocarbons

n

-Octane on Res-Sil C Column,

p. 139

Unique selectivity for unsaturated

hydrocarbons.

Excellent resolution of unsaturated

light hydrocarbons gives increased data

accuracy.

cis

-2-Butene and 1,3-butadiene

OPN on Res-Sil C Column,

p. 139

Optimized selectivity for

cis

-2-butene

and 1,3-butadiene resolution.

Increases data accuracy.

Permanent gases

Shincarbon ST Columns,

p. 140

Packed or micropacked

Optimized selectivity for permanent gas

resolution without cryogenic cooling.

Preconditioned.

Increases productivity.

Low-level sulfurs

Rt-XLSulfur Columns,

p. 141

Packed or micropacked

Highly inert for ppbv levels of sulfur.

Eliminates need for PTFE tubing.

Increases data accuracy for low-level

sulfur analysis. Eliminates need for a

special GC setup.

For specific applications, Restek recommends using these optimized columns for better method performance.

Quick Reference Chart