101 HT Specifications
(global patents pending)
Ambient Environment
December 1, 2010
Operating Temperature Range: 0
o
C to 35
o
C
Storage Temperature Range: -20
o
C to 60
o
C
Relative Humidity Range: 0 to 100% (non-condensing)
Power Requirements
Less than 300 watts peak power at startup, practical use < 200 Watts for gas or liquid analyses
24 VDC supplied from external power supply, 100-240VAC using 50/60Hz AC
Safety
General purpose, light industrial (lab instrument environment)
CE Mark and Nationally Recognized Testing Laboratory (NRTL) certified pending (TUV Rheinland)
Gas Supplies
50 PSIG, 99.995% H
2
or He at up to 250 ml/min, 50 PSIG zero air for FID operation
Sample Requirements
(via split/splitless injector with septum purge)
Air or gaseous samples at 0 to 50 PSIG at ambient temperature
Membrane, SPME and static and dynamic headspace extracts
Direct liquid injections neat or dilute organic solvents (DCM, hexane, MEK, toluene, methanol, CS
2
etc.)
Dimensions
17" wide by 8.5" deep by 11" high, ~ 20 lbs
Uninterrupted power supply and data acquisition computer external to the base unit
Controls/Outputs
All functions and parameters via ethernet or RS-232 using ChromPerfect™ software
Start analysis from keyboard or GC
Set method from external computer using ChromPerfect software
50-100Hz digitization (detector dependent) on each column, 24 bit resolution, auto zero on each run
Trigger in and ready out signals plus an array of others via ChromPerfect
Front Panel Displays
Temperature and pressure readings, function on/off, other
Power on/off
Status of analysis columns (isothermal, programming, cool down, ready, cycles run, other)
Standard Equipment
One capillary column, 2m long, 100µm, Mxt 1-HT, temperature programmable from 0.1 to 5
o
C per second from 5
o
C above ambient to 400
o
C (maximum
temperature software limited to be no greater than the limit for the Mxt 1 HT column installed, isothermal operation is available).
Flame ionization detection, data rate 100 Hz
Gas and liquid inlet for syringe injection of samples or automated gas and liquid sample valves available
Performance
(application dependent)
Repeatability of ± 1% RSD or better (area) and of ± 0.1% RSD or better (retention times)
Analysis times for fuel and fuel components: can be <60 seconds and up to 300 seconds
Dynamic range: depends on detector used and application (FID typically 10
5
)
Data Processing and Instrument Control
Note: computer system is integral and necessary component of the analysis system and includes the following requirements:
RS-232 or USB to RS-232 adapter, ethernet
Windows XP or newer operating environment
ChromPerfect software for single column data acquisition via RS-232 serial or ethernet ports
CALIDUS 101 HT comes with LineUp peak alignment and Simdist-2000 simulated distillation software fully integrated.