restekapp07 - page 95

For permission to reproduce any portion of this application note, please contact Restek’s publications/graphics department by phone (ext. 2128) or FAX.
©Copyright 2001, RestekCorporation
Product Listing, continued:
Uniliner
®
Sleeves
Direct InjectionLiners forAgilent
ID
***
/OD&Length
&FinniganGCs
(0.32/0.53mm ID)
Benefits/Uses:
(mm)
Each
*
5-pack
Uniliner
®†
trace, active samples, high recovery& linearity
4.0 ID, 6.3OD x 78.5
20335
20336
Cyclo-Uniliner
®†
trace, dirty, highMWactive samples, high recovery& linearity 4.0 ID, 6.3OD x 78.5 20337
20338
Open-topUniliner
®
withWool
trace, dirty active samples, high recovery& linearity
4.0 ID, 6.3OD x 78.5 20843
20844
Direct InjectionLiners forAgilent
ID
***
/OD&Length
6890GCs
(0.32/0.53mm ID)
Benefits/Uses:
(mm)
Each
*
5-pack
DrilledUniliner
®†
allows direct injectionwhen using anEPC-equippedGC 4.0 ID, 6.3OD x 78.5
21054
21055
Direct InjectionLiners forVarianGCs
ID
***
/OD&Length
(0.32/0.53mm ID)
Benefits/Uses:
(mm)
Each
*
5-pack
Uniliner
®
trace, active samples, high recovery& linearity
4.0 ID, 6.3OD x 72
20345
20346
Cyclo-Uniliner
®
trace, dirty, highMW, active samples, linearity
4.0 ID, 6.3OD x 72
20347
20348
Open-topUniliner
®
w/Wool
**
trace, dirty, active samples, high recovery& linearity
4.0 ID, 6.3OD x 72
20845
20846
Direct InjectionLiners for
ID
***
/OD&Length
ShimadzuGCs
(0.32/0.53mm ID)
Benefits/Uses:
(mm)
Each
*
5-pack
128mmUniliner
®
trace, active samples, high recovery& linearity
3.0 ID, 5.0OD x 128
20872
20873
128mmCyclo-Uniliner
®
trace, dirty, highMWactive samples, linearity
3.5 ID, 5.0OD x 128
20874
20875
99mmUniliner
®
trace, active samples, high recovery& linearity
3.0 ID, 5.0OD x 99
20876
20877
99mmCyclo-Uniliner
®
trace, dirty, highMWactive samples, high recovery& linearity 3.0 ID, 5.0OD x 99
20893
20894
94mmUniliner
®
w/Wool
**
trace, dirty, highMWactive samples, high recovery& linearity 3.0 ID, 5.0OD x 94
21713
21719
Direct InjectionLiners for
ID
***
/OD&Length
Perkin-ElmerGCs
(0.32/0.53mm ID)
Benefits/Uses:
(mm)
Each
*
5-pack
Uniliner
®
trace, active samples, high recovery& linearity
3.5 ID, 5.0OD x 100
20855
20856
Cyclo-Uniliner
®
trace, dirty, active samples, linearity
3.5 ID, 5.0OD x 100
20857
20858
trace, dirty, active samples,
Auto SYSOpen-topUniliner
®
w/Wool
**
high recovery& linearity
4.0 ID, 6.2OD x 92.1 20837
20838
Auto SYSCyclo-Uniliner
®
trace, dirty, highMWactive samples, linearity
4.0 ID, 6.2OD x 92.1
20839
20840
Split Liners for 5000-6000
ID
***
/OD&Length
SeriesGCs
Benefits/Uses:
(mm)
Each
*
5-pack
Open-topUniliner
®
w/Wool
**
trace, dirty, active samples, high recovery& linearity
4.0 ID, 5.5OD x 79.5
20841
20842
Direct injectionLiners for 8000
ID
***
/OD&Length
&TRACE
SeriesGCs
Benefits/Uses:
(mm)
Each
*
5-pack
Uniliner
®
w/Wool
trace, active samples, high recovery& linearity
5.0 ID, 8.0OD x 105
21005
21006
Trademarks:
Uniliner, Rtx, and Stabilwax (Restek). TRACE (ThermaQuest Corp.).
*Add the suffix “-205” to the catalog number to order without wool.
**These liners are packedwith fused silicawool. To order glass wool instead, add the suffix “-202” to the liner’s catalog number.
***Nominal ID at syringe needle expulsion point.
†TheseUniliner
®
sleeves are for split/splitless injection ports.
1...,85,86,87,88,89,90,91,92,93,94 96,97,98,99,100,101,102,103,104,105,...324
Powered by FlippingBook