VICI-Valco Catalog #60 289p - page 259

258
|
VICI AG International Sales: + 41–41–925–6200 Fax: + 41–41–925–6201
|
general reference
Glossary
UNDERCUT
FITTING
BODY
MOUNTING
NUT
PANEL
TUBING
PLUG
TUBING
PLUG
TUBING
CLEANLY SWEPT
CONNECTING
VOLUME
DEAD
VOLUME
microelectric
actuator
closemount
hardware
valve
A
Adapter:
a type of fitting which provides a method of joining two
components of differing thread types or systems.
Analytical column:
a long narrow tube packed or coated with
one of many available chemically diverse compounds that
can separate the components in a sample according to their
boiling point, polarity, molecular size, or combination thereof.
A column of some kind is used with most chromatographic
techniques.
B
Backflush:
the use of valving to reverse the flow through a
column in order to “backflush” or purge heavier components
from the column.
Biocompatibility:
defines the materials used in a system (i.e.
fittings, tubing, and valves) that do not change the bioactivity
of the biological substances that come into contact with the
surface of these materials. Note that in chromatographic
systems, the tubing and column contribute over 99% of the
surface area and the valves and fittings are insignificant.
Bore:
the diameter of the minimum orifice through the fitting;
see
capillary bore, through-type bore,
and
large bore
.
Bulkhead fitting:
a type of fitting in which the fitting body is
inserted through an instrument panel or mounting bracket, to
which it is affixed with a mounting nut. The Valco fitting body
is uniquely undercut so that it “bites” into the panel when the
mounting nut is tightened, eliminating the need for a lock
washer.
Butt connection:
a type of connection in which the two tube
ends are directly and squarely in contact, usually effected
with a through-type union. Typically used with fused silica
connections, or small bore metal tubing.
C
Cap:
a cap is used to dead-end a piece of tubing with a nut and
ferrule attached.
Capillary bore:
the smallest available standard orifice in a given
fitting design (usually 0.25 mm). Typically denoted by suffix “C”
in the product number.
Closemount hardware:
the mounting components providing the
most direct, shortest attachment of valve to actuator.
Compression fitting:
a style of fitting in which a threaded
nut compresses a tapered ferrule onto tubing as the nut is
tightened. Valco metal ferrules cut a ring into the tubing wall
while polymer types rely on surface compression to form a seal.
Connecting volume:
the volume between two or more
connections. This may be cleanly swept, thus not contributing
to peak distortion, or may be “dead volume” such as that found
in fittings with larger bores than the connecting tubing.
Cross:
a type of distribution fitting which connects four pieces of
tubing, arranging them in the pattern of a cross.
D
Dead volume:
(drawing at right)
any volume which
a component
introduces to a
system that is not
cleanly swept and
relies on diffusion
to clear the space.
See
connecting
volume
.
Detail:
see
fitting
detail
.
Distribution fitting:
a generic term for
tees, crosses, and
manifolds, used to
provide multiple
access points to “distribute” a gas or liquid through a system.
CAUTION!
Using a distribution fitting in reverse to coalesce
multiple streams may create dead volume. Special manifolds
are available for this application.
CHROMalytic TECHnology Pty Ltd AUSTRALIAN Distributors e-mail: