Dynacalibrator® Calibration Gas Generators
Deliver precise concentrations from ppb to high ppm
Use Dynacal® permeation devices as the trace gas source, with front panel
access to the permeation chamber
Proprietary constant temperature system controls chamber temperature at
a set point with ±0.1°C accuracy
Choice of plumbing and flow configurations
Model 120
Portable Dynacalibrators®
Model 150
Dynacalibrators®
VICI Metronics Dynacalibrators allow you to verify the accuracy of analytical
data from air pollution monitoring, industrial hygiene surveys, odor surveys, and
other instruments measuring gas concentration. All models enable calibrations
traceable to NIST standards for almost any gas analyzer, in the lab or in the field.
The design takes full advantage of all the conveniences inherent in our Dynacal®
permeation devices to generate and deliver precise concentrations ranging from
ppb to high ppm for hundreds of different compounds. Standard features on all
our models, from the most basic Model 150 to the most fully-equipped Model
500, facilitate accurate, reproducible, trouble-free calibrations time after time.
above ambient to 110°C) means the
end user can generate a wide range
of volumetric concentrations for both
low and high vapor pressure chemical
compounds, establishing or changing
the desired volumetric concentration
by simply varying the carrier flow.
Temperature control with an
accuracy of ±0.01°C from 5°C above
ambient to 110°C
Ultra compact
PPB to high PPM range
At only 6" wide x 15" deep x 7" high
and 10.5 pounds, the Dynacalibrator
150 is a compact calibrator capable of
delivering the precise concentrations
you require. A passivated glass-coated
stainless steel permeation chamber
houses the permeation device(s).
Carrier and dilution flow rates must
be supplied and measured externally.
The digital temperature controller
maintains the chamber temperature at
a set point with an accuracy of ±0.01°C,
traceable to NIST standards.The wide
range of temperature settings (5°C
Completely portable
Pump powered by rechargeable
battery or a 12 VDC source (inverter
with cigarette lighter plug provided)
Available temperature control from
5°C above ambient to 100°C
Utilizes permeation devices – no
bulky cylinders
Standard features on Model 120
include a glass or Teflon® permeation
chamber with screw cap access,
solid state proportional temperature
controller with digital readout of set
point and chamber temperature,
heater switch with LED indicator,
flowmeter and flow control valve, span
and overflow outlets, 12 VDC internal
pump, activated charcoal scrubber, and
molded fiberglass case.