Volatile Organics Analysis
Rtx®-502.2 Columns
(fused silica)
(proprietary Crossbond® diphenyl/dimethyl polysiloxane phase)
• Application-specific columns with unique selectivity for volatile organic pollutants.
The Rtx®-502.2 column is cited in US EPA Method 502.2 and in many gasoline
range organics (GRO) methods for monitoring underground storage tanks.
• Excellent separation of trihalomethanes; ideal polarity for light hydrocarbons and
aromatics.
• Stable to 270 °C.
An Rtx®-502.2 column will enable you to quantify all compounds listed in US EPA
methods 502.2 or 524.2, whether you use a mass spectrometer or a PID in tandem with
an ELCD. The diphenyl/dimethyl polysiloxane based Rtx®-502.2 stationary phase pro-
vides low bleed and thermal stability to 270 °C. A 105-meter column can separate the
light gases specified in EPA methods without subambient cooling. Narrow bore
columns can interface directly in GC/MS systems.
*Maximum temperatures listed are for 15- and 30-meter lengths. Longer lengths may have a slightly reduced
maximum temperature.
Rtx®-Volatiles Columns
(fused silica)
(proprietary Crossbond® diphenyl/dimethyl polysiloxane phase)
• Application-specific columns for volatile organic pollutants.
• Stable to 280 °C.
Rtx®-Volatiles columns were the first columns designed specifically for analyses of the
34 volatile organic pollutants listed in US EPA methods 601, 602, and 624. With these
columns, you can quantify all compounds listed in these methods, whether you use a
mass spectrometer or a PID in tandem with an ELCD. The diphenyl/dimethyl poly-
siloxane based Rtx®-Volatiles stationary phase provides low bleed and thermal stability
to 280 °C. Narrow bore columns can interface directly in GC/MS systems.
Solutions For Your Environmental Analyses
Visit us at
Improved best-in-class GC columns • Standards • Industry experts at your service.
Chroma
BLOG
raphy
Topical and timely insights from top
chromatographers.
Visit us at
blog.restek.com
ID
df
temp. limits
30-Meter
60-Meter
75-Meter
105-Meter
0.25mm 1.40µm -20 to 250/270°C 10915
10916
0.32mm 1.80µm -20 to 250/270°C 10919
10920
10921
0.45mm 2.55µm -20 to 250/270°C
10986
0.53mm 3.00µm -20 to 250/270°C 10908
10909
10910
ID
df
temp. limits
20-Meter
40-Meter
0.18mm 1.00µm -20 to 250/270°C 40914
40915
ID
df
temp. limits*
30-Meter
60-Meter
105-Meter
0.25mm 1.00µm -20 to 270/280°C 10900
10903
0.32mm 1.50µm -20 to 270/280°C 10901
10904
0.53mm 2.00µm -20 to 270/280°C 10902
10905
10906