MRC-2013-Catalog - page 716

716
W
WATER-PURIFICATION
RO/UP water systems
Model
Standards
Eliminating
endotoxin
Low TOC
Comprehensive
WPL-RO-UP-15-S
WPL-RO-UP-30-S
WPL-RO-UP-15-UF
WPL-RO-UP-30-UF
WPL-RO-UP-15-UV
WPL-RO-UP-30-UV
WPL-RO-UP-15-UVF
WPL-RO-UP-30-UVF
Flow procedure
PF+KDF+AC+RO
+AC-DI+TF
PF+KDF+AC+RO+
AC+DI+UF+TF
PF+KDF+AC+RO+
UV+AC+DI+TF
PF+KDF+AC+RO+
UV+AC+DI+UF+TF
Application
GC,HPLC,IC,ICP
PCR, weather analysis
Amino acid analysis
Reagent preparation
Molecular biology
Cell & tissue cultivation
Life science,IVF
electrophoresis
HPLC,IC,ICP-MS
TOC & organism analyse
CF-AAS,toxicology study
Environmental analyse
HPLC,IC,ICP-MS,CF-AAS
Physics,electrochemistry,
Molecular biology,
Cell cultivation
Pure
water
quality
Resistivity
18.2 M
Ω
-cm@25
O
C
Heavy metal
< 0.1ppb
TOC
<10 ppb
<3 ppb
Bacteria
<1 CFU/ml
Endotoxin
-
<0.001 EU/ml
-
<0.001 EU/ml
Particle(>0.22μm)
<1 / ml
TDS (RO water)
5-10 ppm*
Technical
spec.
Output(25
O
C)
15/30 Liters/hour*
Moment output
1.5 Liters/min (with pressure tank) (Less output with UF/UV cartridge)
Pure water outlet
RO Water, Ultra pure water
Dimension /
Weight / Power
W×D×H: 50×36× 54cm / 20-30 Kg / 220V/50HZ, 120W
Control
system
Mode display
Power on, program, inlet rinse, producing, full, circle, regular outlet,
disinfection, consumables replacing reminder
Safety
low pressure and full water alarm, password, auto-reset,
outlet forbidden when alarm or disinfection status
System monitor
Monitoring quality of inlet water, RO water and ultrapure water,
temperature, used and left time of consumables
Water source required
Tap water; inlet TDS<200 ppm, 1-40
O
C, 1.0-3.5 kg/cm2
(if inlet TDS>200ppm, pretreatment is recommended)
Purificati
on
system
Pretreatment unit
5μm spun fiber filter×1+ Long-effective KDF filter×1+ Granular active carbon filter×1
(30L model: 10” PP filter×1+10” KDF filter×1+10”granular active carbon filter×1)
RO unit
100 GPD RO membrane×1 (30L model: 2×100 GPD RO membrane)
Subsequent unit
Post active carbon filter×1 +Ultra pure polishing resin cartridge× 0.2 +4μm terminal filter×1
UV model:+Double wavelength(254&185 nm)UV cartridge×1
UF model:+ 5000 Doulton UF cartridge×1
UVF model:+Double wavelength(254&185 nm)UV cartridge×5000+1 Doulton UF cartridge×1
Standard configuration
Main body(including:1 set cartridge)4 gallon tank
WPL-RO-UP Systems, Ultra Pure Water Systems (Tap water inlet)
*
Inlet water: TDS200ppm, 25
O
C, 50psi and 15% recovery rate.
**
GPD=gallon per day 1 gallon=3.8L.
***
The quality of inlet water will effect output’s and cartridge’s life.
PF: Pretreating, KDF: Kinetic degradation fluxion, AC: Active carbon, RO: Reverse osmosis, DI: Ion exchange,
UV: Ultraviolet (Double wavelength: 254&185nm), UF: Ultrafiltration TF: Terminal filter.
1...,706,707,708,709,710,711,712,713,714,715 717,718,719,720,721,722,723,724,725,726,...738