FURNACES
F
Rapid Heating, 1100°C, 1200°C, 1300°C
Standard Features:
1100°C or 1200°C maximum operating temperature.
5, 13, or 23 Liter chamber volumes.
Ambient to 1100°C in as little as 10 minutes
Rapid thermal response from free radiating coiled wire elements
Low thermal mass insulation for fast response & energy efficiency
Up & away door keeps heated surface away from the user
301 controller with single ramp to set-point & process timer
Hard wearing, dust free hearth
Easy access to elements & controls simplifies maintenance & servicing.
RWF 12/5
Model
Max
temp
(°C)
Heat
up
time
(mins)
Dimension
Volume
(Liters)
Max power
(W)
Thermocouple
type
Weight
(kg)
Power
supply
Inside (mm)
Outside (mm)
(door open)
Holding
power (W)
RWF 11/5
1100 10 H130xW160xD250 H585xW375xD485
(800)
5
2750
680
K
28
230V
single phase
RWF 11/13
1100 11 H195xW210xD325 H655xW435xD610
(905)
13
5000
1200
K
45 230V single
or 2 phase
RWF 11/23
1100 13 H220xW260xD400 H705xW505xD675
(990)
23
9100
1800
K
65 Universal
RWF 12/5
1200 12 H130xW160xD250 H585xW375xD485
(800)
5
2750
820
R
28
230V
single phase
RWF 12/13
1200 13 H195xW210xD325 H655xW435xD610
(905)
13
5000
1450
R
45 230V single
or 2 phase
RWF 12/23
1200 15 H220xW260xD400 H705xW505xD675
(990)
23
9100
2100
R
65 Universal
“Universal” models are easily altered between single phase(220V), 3 phase+neutral (e.g. 380/220V) & delta (e.g. 220V) electrical supplies.
Continuous operating temperature is 100°C below maximum temp. Holding power is measured at the continuous operating temp.
RWF Series, 1400
°
C, 1500
°
C, 1600
°
C, High Temp Furnaces, Rapid
Heating Chamber Furnaces
Free radiating wire-wound elements and highly efficient low thermal mass
insulation are combined to provide a furnace for light to medium laboratory
applications where rapid thermal response is important.
Options:
Over-temperature protection (recommended to protect valuable contents & for unattended operation)
2
phase supply at no extra cost above 13 Liters
8 or 20 segment programmer
RS232 communications
A variety of
retorts & modifications is available for working with modified atmospheres.
Standard Features:
1200°C or 1300°C maximum operating temperature.
36, 65, 131, or 200 Liter chamber volumes.
Free radiating coiled wire elements
Low thermal mass insulation for fast response & energy efficiency
Up & away door, keeps heated surface away from the user
Controller, with single ramp to set-point & process timer
Hard wearing refractory hearth plate, resists damage & supports heavier loads
Heating elements are easily serviced from the front of the chamber.
GPC 12/36
Model
Max
temp
(°C)
Heat
up
time
(mins)
Dimension
Volume
(Liters)
Max
power
(W)
Thermocouple
type
Weight
(kg)
Power
supply
Inside (mm)
Outside (mm)
(door open)
GPC 12/36
1200 37 H250xW320xD450 H810xW690xD780
(1105)
36
9000
R
100 Universal
GPC 12/65
1200 40 H278xW388xD595 H885xW780xD945
(1245)
65
14000
R
165 3 phase
GPC 12/131
1200 150 H350xW500xD750 H1652xW1110xD1280
(2310) Floorstanding 131
18000
R
400 3 phase
GPC 12/200
1200 - H400xW600xD900 H1702xW1350xD1350
(2410) Floorstanding 200
24000
R
518 3 phase
GPC 13/36
1300 47 H250xW320xD450 H810xW690xD780
(1105)
36
9000
R
120 Universal
GPC 13/65
1300 45 H278xW388xD595 H885xW780xD945
(1245)
65
14000
R
165 3 phase
GPC 13/131
1300 - H350xW500xD750 H1652xW1110xD1280
(2310) Floorstanding 131
18000
R
400 3 phase
“Universal” models are easily altered between single phase(220V), 3 phase+neutral (e.g. 380/220V) & delta (e.g. 220V) electrical supplies.
Continuous operating temperature is 100°C below maximum temp. Holding power is measured at the continuous operating temp.
GPC Series, 1200
°
C, 1300
°
C, large Capacity laboratory Chamber Furnaces
Designed for general workshop and laboratory use, the GPC range has the
styling and features of the laboratory furnace range with the advantages of
a larger chamber size and higher loading capacity.
Options:
Over-temperature protection (recommended to protect
valuable contents & for unattended operation)
8 or 20 segment
programmer
RS232 communications
A range of inconel (NiCr) retorts to
work with modified atmospheres up to 1100°C.