CALORIMETERS
C
Calorimeter
High Efficiency and Automation
Test in turn without waiting
With bomb identifier, up to four
bombs can be recognized,
operators can prepare other
bombs while testing thus
improvement gained in
efficiency & operating time.
Test finished automatically
Automatic oxygen filler
equipped, oxygen filling
by one press.
Automatic controlling of
water volume, filling,
heating, emptying and
jacket water circulation.
Automatic sample ignition.
Automatic temperature
rise measurement and
result calculation.
Model
CALO-B
Analysis Time
< 25 min
Heat Capacity Stability
0.20% within three months
Heat Capacity Precision
0.2%
Temperature Resolution
0.0001K
Power Requirement
220V(-15%-10%), 50Hz
Max Power
0.5kW
Gas Requirement
99.5% purity of oxygen
Water Requirement
Distilled water
Size / Net weight
528x330x380mm / 30Kg
Model
CALO-11A
CALO-11
CALO-13
CALO-15
Standard Layout
Calorimeter, Lenovo PC
(Desktop), Printer
Calorimeter, Water Tank, Lenovo PC (Desktop), Printer
Type
Vertical type
Benchtop
-
-
Size
437x554x1040mm 432x560x393mm 432x560x393mm 432x560x393mm
Net weight
95kg
60kg
60kg
60kg
CALO-B, Calorimeter
Sectional Drawing of Jacket/Lid With Helix Tube Inside
Jacket Lid
With Helix Tube
Jacket
Temperature
Control Device
Circulation
Driving Device
Helix Tube in Lid
Helix Tube
Bucket
Easy to Operate, Handle and Maintain
Easy-to-use Windows- based software.
Easy data handing, real time data can be
transmitted through internal network.
With CAN bus interface, several calorimeters can
be controlled by a single PC.
Connected with balance and network by standard
interface RS232.
Durable bombs need hydrostatic pressure test only
once a year.
Features
Weighing the weight and measuring the water
temperature of bucket manually, then the
calorimeter will finish the whole test automatically.
Simple structure, easy for maintenance.
Durable bombs need hydrostatic pressure test only
once a year.
CALO-15
With PCI interface, several calorimeters can be
controlled by a single PC.
Connect with balance and network by standard
interface RS232, real time data can be transmitted
through Internal network.
Easy-to-use Windows-based software, easy data
handling.
CALO-B
Less sensitive to power supply
Unique design of inverter which can purify and stabilize the
power supply, ensures the calorimeter will not be affected
by the fluctuation of power voltage (from 160V to 240V)
and frequency.
CALO-15
Power Inverter