CALIBRATION
C
Temperature/Pressure
CALI-1200HN
High Temperature Ceramic Dry Block: Calibrator. Stable High (1200°C) Temp.
Source for Calibration of Multiple Sensors (up to 6) at High Temperature.
Range: 300°C above ambient to 1200°C.
Stability: Better than ±0.5°C (below 600°C).
Accuracy: Better than ±3°C. Resolution: 1°C.
Size: W205xD365xH480mm. Weight: 13kg.
Well Depth - 150mm.
High Stability.
RS - 232 Interface.
Multi-Hole 1 Interchangeable (Thermowell) Inserts - to suit.
High Accuracy.
Auto - Tune PID Control. Semi Portable.
CALI-1200HN, High Temperature Calibrator
CALI-1500HN
Very High Temperature Ceramic Dry Block: Calibrator
Temperature Range: 500 to 1500°C.
Stability: ±2°C.
Accuracy: ±0.5% of Span. Resolution: 1°C.
Size: W345xD510xH830mm ( with wheel).
Fast, Stable & Accurate. Auto-tune PID Controller.
Heating Element: Silicon Carbide.
Dry Block: - High Alumina Ceramic
Single (Interchangeable) & Multi Hole (Fixed).
Immersion Depth - 250mm.
Interchangeable Single Hole Thermowells-ID 7/11 & 15 mm*.
Semi Portable - Castor Wheels. RS-232 Computer Interface.
CALI-1500HN, Very High Temperature Calibrator
CALI-FB600L
Fluidised bath switch test facility.
Ideal for calibration of Multi Type add shaped sensor.
Temperature Range: RT+20 to 600°C.
Stability: ±0.5°C.
Accuracy: ±1.5°C. Resolution: 1°C.
Size: W730xD470xH780mm.
Fast, Stable & Accurate.
Immersion Depth - 250mm/400mm.
Semi Portable - Castor Wheels optional.
RS-232 Computer Interface.
CALI-FB600L, Temperature Calibrator
CALI-PP
PP: Ranges: -0.85 to 2/7/10/20 Bar PPH : Ranges: -0 to 200/400 Bar
Temperature Range: 0 to 50°C (Automatic).
Accuracy: PP (± 0.05% F.S. + 1digit). PPH (± 0.025% F.S. + 1digit)
Size: L330xB230xH125mm for 2/7/10 bar. L330xB230xH175mm for 20 bar.
Advanced Microprocessor Based. Light Weight 1 Compact.
Trendy, Elegant ‘Rugged’ Case - Truly Portable.
Resolution: Minimum 5 digits. Large Graphic Display.
Touch Membrane Keypad with 15 Selectable Pressure Units eg
mbar, bar, Kg/cm², Psi, in Hg, mm Hg, mm H
²
O, cm H
²
O, m H
²
O, in H
²
O,
ft H
²
O, Pa, MPa, KPa, atm.
DC Current Measurement: Active Loop: 50 mA, Passive Loop: 25 mA.
Switch test Capability & Zero Offset facility.
Audio & Visual Alarms for Over Pressure.
NI- MH Rechargeable Batteries with Low Battery Indication.
CALI-PP/PPH, Semi-Portable Pressure Calibrators
Pressure Transducer - All Media Compatible with SS316 .
Integral 1 In-Built Vacuum & Pressure Hand Pump, Vernier Adjustment & Release Valve .
1...,90,91,92,93,94,95,96,97,98,99 101,102,103,104,105,106,107,108,109,110,...738