|
|
|
& a HI-TECH “Resource” > 4 U !
|
|
|
|
|
but see “Scams” > New”Phishes”
|
|
|
|
|
|
CHROMTECH : Specialists in Chromatography Chromatography Fluid Transfer Products : & FOR ! All Your Laboratory Needs ! - Importers & Distributors in AUSTRALIA
|
|
|
|
|
|
|
|
![](./a_ArrowLine_1.gif) |
|
Chemical Detection - DET- Overview 2010
|
Detection Principles PDF
Ion Sources PDF Modes PDF some Theory of DPD,TID-1,CFID PDF
|
Latest DET REPORTS
May 10; July 11 (DET ceramic vs Agilent Glass beads/ problems
|
More Reports & H’ware
|
GC Equipment PDF Recent Literature PDF
|
DET-SRI Compact TID GC PDF TID-1-N2(O2) PDF TID-1 using Varian Electronics PDF
|
|
|
|
|
|
Latest DET Reports
|
DET REport June2014
|
|
|
|
|
|
novel applications of the principles of THERMIONIC SURFACE IONIZATION ( and FLAME IONIZATION )
CERAMIC ION SOURCES (Beads) for the NPD (Nitrogen-Phosphorus Detector) and OTHER TID (Thermionic Ionization Detector) MODES, INCLUDING REPLACEMENTS for the AGILENT 6890/7890 NP ION SOURCE (Highest Quality, Best Performance, Lowest Cost, Unlimited Shelf Life). A family of different ceramic coatings provides an easy change from one mode of selective detection to another using the same basic equipment. An ENVIRONMENT FRIENDLY RECYCLING OF DEPLETED ION SOURCES is available for any DET, Agilent, Thermo, SRI, or other brand NPD.
NEW - CATALYTIC COMBUSTION IONIZATION METHOD ( CCID ) for the selective detection of METHYLENE functional groups in Petroleum, Biodiesel, and FAME samples with differentiation between saturated and unsaturated Carbon bonds.
DETECTORS for GAS CHROMATOGRAPHY - hardware designed for custom retrofit onto the existing FID or NPD base on various GC models (e.g., Thermo Trace, Agilent 6890, Varian 3800, SRI 8610, HP5890) - features a concentric cylinder geometry for stream-lined gas flow and optimum ion collection efficiency - (NEW combination of DET Hardware and versatile Thermo Trace NPD Electronics provides unrivaled interchangeable capability for all modes of NPD and TID detection). DET : COMPACT GC for SELECTIVE DETECTION of OXYGENATES & NITRO COMPOUNDS or NITROGEN-PHOSPHORUS COMPOUNDS (NPD) - inexpensive, portable size size GC features novel thermionic detection techniques, 0.32 mm fused silica column and simple interchangeability from one detection mode to another.
STAND-ALONE TRANSDUCERS and DETECTION MODULES.
Outstanding Features:
- multiple modes of detection (NPD, PTID, TID-1, TID-3, TID-5, FTID, FID, Remote FID, Tandem TID)
- unique selective responses to heteroatom compounds (Nitrogen, Phosphorus, Oxygenates, Halogenates, Nitro-compounds, Lead, Tin, Silicon) and Pyrrole vs. Pyridine functional groups.
- inexpensive, simple equipment design, easy to operate and maintain.
|
|
|
|
|
DET Transducers & H’ware
|
|
- DET NPD/TID/FID Retrofits
for Different GC Models PDF
![acrobat-but acrobat-but](./acrobat-but_70.jpg)
|
|
|
|
|
|
Reactor Thermionic Ionisation Analysis (RTIA) PDF
![acrobat-but acrobat-but](./acrobat-but_70.jpg) . . . selective TID/NPD transducer screening of vapors evolved from THERMAL DESORPTION/OXIDATION of nonvolatile liquid residues or solid sample constituents
|
NPD Ceramic Ion Source LIFETIME Considerations PDF
Unique to DET Improved Design : Unlimited shelf-life NOT moisture sensitive: ceramic NOT glass ( problematic ) Constant Current Preferred1500 Hours continuous Use Wide range of Signal and S/N depending on H2 Flow and current
|
|
|
DET retrofits consist of a stainless steel /ceramic tower custom mounted on the existing FID/NPD base on the GC The tower can accommodate DET hex flanged ion sources such that the ion source is positioned on the axis of a collector electrode cylinder. This concentric cylinder geometry provides a streamlined gas flow through the detector, and an optimum electric field for ion collection. For a complete detector, add an Ion Source (USD350) to the following assemblies.
ASK for Current AUD Prices depends on XR AUD”USD
THERMO TRACE GC: NPDITID/FID Tower Assembly, part #010-860-55, $1800 USD. DET hardware and ion sources are compatible with Thermo's NPD electronics which provides Constant Current ion source heating and a wide range of polarization voltage selections. This combination of DEThardware and Thermo NPD electronics provides the most versatile NPDITID detection currently available. Different modes of detection are achieved by simple changes in the type of ion source, and in the type of detector gases.
VARIAN GC MODELS: NPDITID/FID Tower Assembly, part #010-860-20, $1550 USD. DET hardware and ion sources are compatible with Varian's TSD electronics which provides Constant Current ion source heating at a fixed polarization of -4 V. For modes of detection other than NPD, a stand-alone DET Constant Current Supply provides a selection of higher polarisation voltages which provide more sensitive detection than the Varian supply. Optional DET Current Supply, part #001·901-01 (115Vac), $1760.
SRI INSTRUMENTS: NPDITID/FID Tower Assembly, part #050-864-98, $2350 USD. DET hardware is compatible with signal measurement using SRI's FID/NPD amplifier. DET ion sources with a bare wire termination can be powered with SRI's NPD electronics, but setting power levels is not very user friendly. An improvement is to use the stand-alone DET Current Supply described above, and ion sources with a Twinex connector . . . as is standard on Agilent, Thermo, and Varian instruments. HP 5890 (same equipment fits the FlD base on an Agilent 6890)
NPD/TID/Remote FID/FTID Tower Assembly, part #040-862-12, $1850 USD. DET hardware is not compatible with the 5890 detector electronics,so the stand-alone DET Current Supply and a stand-alone Electrometer (Keithley 6480 Picoammeter recommended) are required. In addition to NPD and TID modes, this equipment can be used for a Remote FlD mode for selective detection of P, Sn, Pb, and Si, or an FTID mode for selectivity to N and CI. DET Current Supply as above, USD1760; Keithley Picoammeter, $1800
|
|
|
|
|
DET Innovations in Chemical Detection
some DET Transducer Structures some DET Transducer Structures PDF 15p
![acrobat-but acrobat-but](./acrobat-but.gif) Example and Applications . . . see below
|
DET Structure Examples p1-4 Schematics p5-6 PTID - enhanced Signal for P - suppressed N response. p7 RTIA - Reactor Thermionic Ionisation Analyser p8 FID & HWCID & CFID - universal response to ALL Organics TFID Thermionic /FID
|
FTID Principle of Detection : Samples combusted in a H2-CH4-Air flame. Electronegative combustion products re-ionised by thermionic surface ionisation downstream of the flame. FTID-2 Halogen Selective p14
|
PTID Principle of Detection : Samples decompose in an ignited H2-Air chemical boundary layer around a hot thermionic surface. High H2 and Air flows suppress N response and provide very large P signals PTID Phosphorus Selective p11
|
TID-1 and TID-3 : modes of detectuion are simple, inexpensive modifactions of Agilent 6890 or DET NPD equipment. Both operated with a detector environment of either N2 or Air ( NO H2 required ) depending on the selectivity required. The ceramic coated TID-1 source is electrically heated to an operating temp of 400-600C, while TID-3 is 600-800C. Both ion sources are polarised at -45V with respect to the surrounding ion collector. Ion source polarisation and heating power are provided by a stand-alone DET Constant Current Supply module TID-1 and TID-3 ion source configurations fit into the Agilent 6890 NPD equipment and into DET NPD equipment designed to mount onto HP5890, SRI8610C or Varian GCs. Negative ion detection signals can be measured with the Agilent 6890 NPD elctrometer, Varian TSD electrometer, SRI FID/NPD electrometer or with a DET electrometer.
|
Tandem NPD and TID-1 : drugs; cocaine (NPD), Heroin(TID-1) p11 TID-4 - Best N Detectivity p11 TID-3 : Selectivity for Trihalomethanes p13, Polybrominated Diphenyl Ethers TID-1 Oxygenates p12 - ethanol in gasoline - Carboxylic Acids - Nitro Cpds - explosives,DNPF-aldehydes, MethylParathion, 4-Nitrophenol p11 - Trace Water in Solvents and Petroleum Samples Organically-Fueled Remote FID : Lead, Tin, Phosphorus, Silcon p13
|
|
|
An Extensive LIBRARY of Selective Detection Applications
|
- sub-picogram detection of NP pesticides and drugs ( NPD )
- exceptional femtogram sensitivity for Nitro explosives liek2,4-Dinitrotoluene and TNT, as well as Nitro pesticides like Methyl Parathion (TID-1 mode )
- sub-picogram detection for some Halogenated pesticides like Heptachlor, Dieldrin, Chlordane, Pentachlorophenol, Atrazine (TID-1 mode )
- low picogram detection of Trihalomethane purification byproducts in drinking water (TID-3 mode )
- Selective detection of Ethanol and other alcohols in Petroleum and Biofuels ( TID-1 N2 mode )
- selective detection of Acetic, Formic and other carboxylic acids in Wine and other food and flavor analyses (TID-1 mode )
- selective detection of linear chain Hydrocarbons and FAMEs in petroleum and biofuels with discrimination between saturated and unsaturated Carbon bonds ( Catalytic Combustion ionisation )
- picogram detection of BisPhenol A (BPA) and phthalates in food packaging products (TID-1 mod )
- detection of glycerol and Glycols in wine and food products ( TID-1 Nitrogen )
- detection of Poly Brominated Diphenyl Ethers (PBDE) flame retardants used on packaging for computiers and other commercial products ( TID-3 mode )
- selective detection of Lead and Tin in environmental samples ( remote FID )
- low picogram detection of Vanillin and Salicylates in food flavorongs ( TID-1 mode )
- detectio of trace Water in solvents and petroleum samples ( TID-Air mode )
- simple detection of the buildup of decomposition products in motor oil versus automobile usage miles of the oil
( TID-a-Nitrogen mode )
- selectiive detection of Acrylamide in processed food products (NPD)
|
if you Search and can’t find it . . . ASK !
|
|
|
|
|
DET Recycle Beads PDF
|
DET Retrofit TID for Different GCs PDF
|
DET Ceramic Beads PDF
|
DET Catalytic Combustion Ionisation PDF
|
|
|
|
|
CT > DET TID GC Detectors
|
|
|
|
some “Unique “ Chromatography : PIC Gallery > GOOGLE SEARCH PIcs > PDF LINKs
|
|
|
|
|
> a TECH Resource for Analytical Chemists ! CT Chromatogrphy > PIC Gallery > via the “courtesy” of ”Our” GOOGLE SEARCH PICs >PDF LINKs > Good IDEAS : Gadjets
|
|
|
|
|
|
|
We’d Welcome YOUR e-Mail /chat Response > but YOUR “Hi-TECH“ “Feedback” is also most Welcome !
|
|
|
|
|
|
|
Corrections ! > ALL ( > MANY ) “HTM” links with “ “ or a “%20” ( space ) in the URL now are “auto-fixed” on-line by NOF15 NOT with “%20” but with “ -” ( hypen ) instead & are NOW W3C / HTML5 OK ! “ _ “ ( underscore ) are also accepted ! with NO dreaded “404” errors !* FlipHTML5 & PDFs ar NOT effected by this “farcical”>”anomaly” !
|
|
|
|
|
NOW ? > (“simlpy” ] use TAWK
from ~31Mar24+ but still ? > & evolving ! albeit TAWK “HELP”itself Is Still a bit “farcical” ! Re AI > garbage-IN > OUT ! . . . but still 2-5year away to minimise obvious “scams > “phishing” etc? Until ALL such OEM > Marketing Cos’ > GET REAL ! FREE ? BUT Still within LIMITS ! U must Pay for necessary extra IF U need to Install ?
|
![Under_Construction_anim-s1 Under_Construction_anim-s1](./Under_Construction_anim-s1_1.jpg) > ANY “Real AI”?
|
|
|
|
|
some of Our Other Main OEM Suppliers !
|
|
|
|
|
some of Our “KEY “ Products
|
|
|
|
|
|
![CT Introduction2021>+ CT Introduction2021>+](./Intro_8.jpg)
|
|
|
preferably Talk to US ! via e-mail > CHAT ? >spasmodic & NOT AI !
|
but NOW “focus” on OUR -m 5 ! pages
|
|
|
FlipHTML5 on Your Mobile ? & “responsive” ! > You may need to “Zoom’ ! ? “+Pinch & Rotate”but > OK ! ? as a preview ! THEN > any PC ! for THE Detail ! but Then FOCUS on -m5
|
|
FlipHTML5 > LIBRARY
|
Collaborative Projects WELCOME ? see here !
|
NEW SEARCH 2023-10 > Try-It! “MS-Bing” SEARCH !
|
|
* multiple Word Step Search Much Improved Over Google > & add “chromtech” OR “chromtech + Australia” to Your “Keywords
|
& even BETTER for ALL of Us !
|
> very “Useful” ! BUT NOT without IT’s “idiosynchrasies” TOO ! BUT it IS ! “AI” ???
|
NOW ! > MS-Copilot & FREE !
|
> extended Versions for MS Office APPs > even more AI BUT U need to “register” & THEN U must PAY for IT ? !
|
|
Main Menu(s) see ( But with/ NO “Flyouts” )
|
* Index-Extended to cover ALL HTMs & with Fly-outs > FLIP(S ( > All PDFs(DIR)
|
|
|