Issue / Date
|
DET Reports
|
DET 62 May 2010 DET62_1-8
PDF FLIP
|
1 Catalytic Combustion Ionisation Method for Selective Detection of CH2 Functional Groups in Petroleum, Biofuel and FAMs including differentiation Between Saturated and Unsaturated Carbon Bonds
2 Selective TID-1 Detection in an Inert Nitrogen Environemnet allows Gasoline to be Used as an Extraction Solvent
3 Critique of Agilents Instructions for the 6890/7890 NPD
|
DET10 TIDPetroleum_1-22
|
Selective TID-1 Thermionic Detection of Oxygenates and High Concentration Hydrocarbons as Related to Analyses of Petroleum and bio-fuels
|
Library of Chromatograms Mar 2008 DET08-03_1-18
PDF FLIP
|
Introduction to the TID-1 Surface Ionisation Process . . . Exceptional Sensitivity and Selectivity to Compounds Containing (1) NO2 Functional Group (2) Chlorine Atoms, chorinated pesticides, chlordane, toxaphene (3) Oxygenates; ethanol in gasoline, formic acid, glycols, phenols (4) Water in solvents
(5) Selectivity for certian drugs NPD/TID-1 (6) PAHs - various Selectitivity (6) Selectivity for CH2 Groups in O2/N2 TID -1
Accessing TID-1 Detection on Different Brand GC Models
|
DET 57 Aug 2008 DET57_1-8A
|
1 Realising the Full Detection Capability of Agilent 6890/7890 GC 2 DET NPD/TID Equipment for Retrofit on Varian GCs 3 Tandem Thermionic Detection on an SRI 8610C GC, 1 Column Effluent - 2 Simultaneous DDetector Signals (TID-1/NPD, NPD/TID-1 and Other Combinations )
4 TID-1 Detction of 1,4-Butanediol Coating on “Aqua-Dots”
|
DET 56 May 2008 DET56_1-8A
|
1 Selective Detection of bisPhenol-A at low Picogtram Levels with TID - a Surface Ionisation 2 Unique Construction of DET Ceramic Ion Sources for NPD and Other Modes of Thermionic Detection
3 Optimum Thermionic Detector Configuration Used in DET and Agilent 6890/7890 NPD Equipment
4 Recycle Used Ceramic Ion Sources from Agilent 6890/7890 NPD
|
DET 53 2007 DET53-07 DET07-53_1-6
|
1 Simple TID-1 Detection of Degradation Products in Used Motor Oil 2 TID-1 Detection of Ethanol in Commercial Gasolines 3 NPD and TID-1 Detection of Drug Compounds 4 NPD Detection of Pesticides
|
DET 52 Sept 2006 (part) DET52_3-4-5-6A
|
1 TID-1 Oxygenates -Wine, tea etc SRI/DET 2 Easy Conversion of Agilent 6890 NPD Equipment to Oxygenate Selective Detection
|
DET 51 Oct 2005 DET52-Oct05
|
1 TID Phthalates 2 NPD Acrylamide 3 Parameters effecting NPD Response
|
DET48 July 2004 DET48-04
|
1 Detection of Polybrominated Diphenyl Ethers (PBDE ) by Selective TID-3 2 Review of DET Equipment for Agilent 6890 GCs A Accessories for 6890 NPD Structure B Detector Structures that Fit on 6890 FID Base
|
DET 47 Jan 2004 DET47-04
|
1 TID-1 Formic Acid in Alcoholic Beverages 2 Thermionic Detection Bromine Compounjs(Bromophenols, PDDE, Haloacetic acids, Trihalomethanes
Modified Collector for 6890 NPD Allows a Wide Range of H2 Flows for More Selectivity Options
|
DET 42 Aug 2001 DET42-01-12
|
1 Wine Analysis - TID-1 Detection of Diacetyl, Formic Acid, Acetic Acid,Propionic and Lactic Acids; Glycerol; and Vanillin 2 Diesel Fuel Analysis - TID-1 and NPD DEtection of Carbazoles. Oxygenates and PAHs 3 NPD & TID-1 on Gasless SRI GC - Explosives, Pesticides, Drugs
|
DET41 June 2001 DET01-41
|
1 “Gasless” GC - New DET Detectors on the SRI GC 2 Improved NP Detection for the Agilent 6890 and Varian 3800 GCs
|